Effectiveness and Safety of Robot-Assisted Brain Stereotactic Surgery: A Systematic Review

뇌정위 수술 보조 로봇 시스템의 안전성과 유효성: 체계적 문헌고찰

  • Park, Sun-young (National Evidence-Based Healthcare Collaborating Agency) ;
  • Jeon, Mi Hye (National Evidence-Based Healthcare Collaborating Agency)
  • Received : 2018.12.04
  • Accepted : 2018.12.27
  • Published : 2018.12.31

Abstract

Objectives: The purpose of this study is to evaluate the safety and effectiveness of Robot-Assisted Brain Stereotactic Surgery with a systematic review. Methods: Electronic literature was searched using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library on 6th April 2017. Two authors screened 1218 citations. Duplicated articles of 456 excluded, the remaining 762 articles were reviewed with title and abstract. Results: A total of 8 studies were selected in this review. The device used in all studies was $ROSA^{TM}$. In one cohort study comparing the intervention ($ROSA^{TM}$) with the control (conventional stereotactic surgery), hematoma was reported no significant difference between groups. In six descriptive studies, one study reported hematoma 10% (10/100) and temporary nerve impairment 6% (6/100) using the ROSA; while five descriptive study did not report any complications. In one cohort, the localization precision were 1.2 mm in the intervention group and 1.1 mm in the control group; the localization success rate as 78.2% in the intervention group and 76.2% in the control group in one cohort; and the average time for surgery as 130 min for the intervention group and 352 min for the control group in one cohort. Four studies reported the localization success rate as 100%; two out of three articles reported the overall time for surgery as 56 min and 90 min, while one article reported the time as less than one hour in 50% of patients (50/100); two articles reported in epilepsy patients, the condition after the surgery was Engel level I in 66.2%, 75% patients, Engel level II-III in 25%, 26.5% patients, and Engel level 4 in 7.3% patients. Conclusion: Robot-Assisted Brain Stereotactic Surgery is a safe and accurate technique that can significantly reduce the time for the brain stereotactic surgery. However, further studies are needed to generalize the results.

Keywords

Acknowledgement

Supported by : 보건복지부

References

  1. Haidegger T, Kovacs L, Fordos G, Benyo Z, Kazanzides P. Future trends in robotic neurosurgery. The 14th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics; 2008 Jun 16-20;Riga, Latvia. New York: Springer;2011.
  2. The Korean Neurosurgical Society. Neurosurgery. 3rd ed. Seoul: The Korean Neurosurgical Society;2008.
  3. Lefranc M, Capel C, Pruvot-Occean AS, Fichten A, Desenclos C, Toussaint P, et al. Frameless robotic stereotactic biopsies: a consecutive series of 100 cases. J Neurosurg 2015;122:342-352. https://doi.org/10.3171/2014.9.JNS14107
  4. Kim YS. Roles of stereotactic surgical robot systems in neurosurgery. Hanyang Med Rev 2016;36:211-214. https://doi.org/10.7599/hmr.2016.36.4.211
  5. Golby AJ. Image-guided neurosurgery. 1st ed. London: Academic Press;2015. pp.477-490.
  6. Gonzalez-Martinez J, Vadera S, Mullin J, Enatsu R, Alexopoulos AV, Patwardhan R, et al. Robot-assisted stereotactic laser ablation in medically intractable epilepsy: operative technique. Neurosurgery 2014;10 Suppl 2:167-172. https://doi.org/10.1227/NEU.0000000000000286
  7. Karas CS, Chiocca EA. Neurosurgical robotics: a review of brain and spine applications. J Robot Surg 2007;1:39-43. https://doi.org/10.1007/s11701-006-0006-6
  8. Gonzalez-Martinez J, Bulacio J, Thompson S, Gale J, Smithason S, Najm I, et al. Technique, results, and complications related to robotassisted stereoelectroencephalography. Neurosurgery 2016;78:169-180. https://doi.org/10.1227/NEU.0000000000001034
  9. Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med 2009;151:264-269. https://doi.org/10.7326/0003-4819-151-4-200908180-00135
  10. sign.ac.uk [Homepage on the Internet]. Edinburgh: Scottish Intercollegiate Guidelines Network [updated 2012 Nov 20; cited 2017 Nov 16]. Available from: http://www.sign.ac.uk/checklists-and-notes.html.
  11. sign.ac.uk [Homepage on the Internet]. Edinburgh: Scottish Intercollegiate Guidelines Network [updated 2015 Nov; cited 2017 Nov 16]. Available from: http://www.sign.ac.uk/assets/sign50_2015.pdf.
  12. Serletis D, Bulacio J, Bingaman W, Najm I, Gonzalez-Martinez J. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J Neurosurg 2014;121:1239-1246. https://doi.org/10.3171/2014.7.JNS132306
  13. Vadera S, Chan A, Lo T, Gill A, Morenkova A, Phielipp NM, et al. Frameless stereotactic robot-assisted subthalamic nucleus deep brain stimulation: case report. World Neurosurg 2017;97:762.e11-762.e14. https://doi.org/10.1016/j.wneu.2015.11.009
  14. Chan AY, Lin JJ, Mnatsakanyan L, Sazgar M, Sen-Gupta I, Hsu FP, et al. Robot-assisted placement of depth electrodes along the long axis of the amygdalohippocampal complex. Interdiscip Neurosurg 2016;6:38-41. https://doi.org/10.1016/j.inat.2016.04.004
  15. Chan AY, Tran DK, Gill AS, Hsu FP, Vadera S. Stereotactic robot-assisted MRI-guided laser thermal ablation of radiation necrosis in the posterior cranial fossa: technical note. Neurosurg Focus 2016;41:E5.
  16. Coca HA, Cebula H, Benmekhbi M, Chenard MP, Entz-Werle N, Proust F. Diffuse intrinsic pontine gliomas in children: interest of robotic frameless assisted biopsy. A technical note. Neurochirurgie 2016;62:327-331. https://doi.org/10.1016/j.neuchi.2016.07.005
  17. Eljamel MS. Robotic neurological surgery applications: accuracy and consistency or pure fantasy? Stereotact Funct Neurosurg 2009;87:88-93. https://doi.org/10.1159/000202974
  18. Li QH, Zamorano L, Pandya A, Perez R, Gong J, Diaz F. The application accuracy of the NeuroMate robot--a quantitative comparison with frameless and frame-based surgical localization systems. Comput Aided Surg 2002;7:90-98. https://doi.org/10.3109/10929080209146020
  19. Ho AL, Feng AY, Kim LH, Pendharkar AV, Sussman ES, Halpern CH, et al. Stereoelectroencephalography in children: a review. Neurosurg Focus 2018;45:E7.
  20. Dorfer C, Minchev G, Czech T, Stefanits H, Feucht M, Pataraia E, et al. A novel miniature robotic device for frameless implantation of depth electrodes in refractory epilepsy. J Neurosurg 2016;126:1622-1628.
  21. Dorfer C, Stefanits H, Pataraia E, Wolfsberger S, Feucht M, Baumgartner C, et al. Frameless stereotactic drilling for placement of depth electrodes in refractory epilepsy: operative technique and initial experience. Neurosurgery 2014;10 Suppl 4:582-590; discussion 590-591. https://doi.org/10.1227/NEU.0000000000000509
  22. Bekelis K, Radwan TA, Desai A, Roberts DW. Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety. J Neurosurg 2012;116:1002-1006. https://doi.org/10.3171/2012.1.JNS111746