• 제목/요약/키워드: Surge voltage

검색결과 446건 처리시간 0.056초

PC 모니터의 시장불량률 감소를 위한 신뢰성 시험법 개발 (Development of reliability test to reduce the field failure rate of PC Monitor)

  • 김준홍
    • 한국산업경영시스템학회:학술대회논문집
    • /
    • 한국산업경영시스템학회 2002년도 춘계학술대회
    • /
    • pp.37-44
    • /
    • 2002
  • In order to review the failure rate of PC monitor under normal environmental conditions, we experimented for various levels of each factors, e.g Power on/off, DPM mode, using voltage, Incoming Surge, Torque strength etc. According to the results of experiment and SN ratios we investigated that the causes of the failure for the horizontal output TR of monitor are Mode change, dispersion of Torque and $h_{FE}$ and these are critical effect. For the new reliability test we suggested that strengthened part tests In IQC branch, Torque change controls in the TR specification are necessary.

  • PDF

지중배전선로용 피뢰기를 고려한 과도현상 해석 (Analysis of Transient Phenomena Considering Arrester in Underground Distribution Line)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.276-278
    • /
    • 2007
  • This paper describes the analysis to install an arrester for an underground distribution line effectively. Currently, the underground distribution cable is protected by the arrester connected with overhead distribution line. However, riser pole arrester can't protect all parts of cable like the end of the underground distribution cable. To solve this problem, we installed the arrester on each cable and have measured the overvoltage made by lightning surge in each situation. The location to get effective results has been decided from the measured voltage above.

  • PDF

10/350${\mu}s$ 서지전류의 크기와 인가횟수에 따른 바리스터의 제한 전압 특성 고찰 (A Study on the Characteristics of Varistor Limiting Voltage Versus Amplitude and Number of Injected Surge Current(10/350ms))

  • 여인식;고영민;김동진;김영선;이기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2138_2139
    • /
    • 2009
  • 본 논문은 ZnO 바리스터에 10/350${\mu}s$ 서지전류를 인가하였을 때 서지전류의 크기와 인가횟수에 따른 바리스터의 제한 전압에 미치는 영향에 관한 것으로 동일한 사양의 시료에 서지의 크기를 다르게 하여 바리스터가 소손될 때 까지 인가하였으며 그 때의 전압을 각각 측정하였다. 그 결과 10/350${\mu}s$ 서지전류의 크기가 증가함에 따라 제한 전압의 크기는 증가하였고 바리스터가 소손되기까지의 서지인가횟수는 감소하였다.

  • PDF

765kV 송전계통에서 고장 발생각에 따른 서지 분석 (Analysis of Surge Voltage according to Fault Inception Angle in 765kV transmission System)

  • 문지영;이유진;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2233_2234
    • /
    • 2009
  • 낙뢰 또는 수목 접촉 등의 일시적인 사고가 발생하면 계통내 접촉 위치에 순간적으로 아크 현상이 일어나게 된다. 일시 고장 원일을 제거하기 위해 기계적으로 전기의 흐름을 단절시켜 고장 원인을 제거하고, 재투입을 통해 계통 복구를 할 수 있다. 아크는 음극과 양극 사이의 방전으로 인한 플라즈마로 설명될 수 있는데 전력 계통에서는 저항으로서 취급할 수 있다. 본 논문에서는 765kV 모델 계통의 아크 현상 시뮬레이션을 통해 고장각 발생 변화에 따른 아크 전압 특성을 분석할 것이다. 또한 아크 특성 분석을 통해 우리는 아크 발생 시 전력 계통에 미치는 영향을 파악하고 분석하고자 한다. 본 논문에서 전력 계통의 과도현상 분석 프로그램인 EMTP(Electro Magnetic Transient Program)를 이용하여 아크현상에 대한 분석 및 765kV계통에서의 아크 고장을 시뮬레이션 하였다.

  • PDF

배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축 (Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system)

  • 김용성;김언석;안건현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가 (Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments)

  • 이기홍;강무성
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

철도용 전기기기의 고장요인 및 절연열화 분석 (Analysis of faust cause & insulation degradation on the electrical equipments for railway)

  • 왕종배;전한준;박옥정;온정근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

HID 램프용 전자식 안정기 개발 연구 (A Study on the Development of the Electronic Ballast for HID Lamps)

  • 이호;오성철;위상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1082-1084
    • /
    • 2001
  • This paper presents a design techniques for an electronic ballast of HID lamps. An electronic ballast for HID lamps usually employs a high frequency resonant inverter and voltage-to-frequency converter to control the output and a half-bridge and series resonant circuit are chosen for the ballast. In this paper, the new lighting method for the stable ignition regardless of lamp types is designed. And this type of ballast has some useful functions such as surge protection, thermal protection, and dimmable function. Moreover the powerline communication skill is also used to transmit a dimming control signal.

  • PDF

전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구 (A Study on electrical equipment effect of apartment customer elevator by power quality)

  • 이희태;김재철;강장규;김기현;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

철도차량 견인전동기의 가속열화수명평가 기술현황 (A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock)

  • 왕종배;김기준;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF