• 제목/요약/키워드: Surge line

검색결과 258건 처리시간 0.033초

Arrester용 Surge counter의 동작특성 (Operating characteristic of surge counter)

  • 김석수;최익순;변진호;이강섭;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.30-33
    • /
    • 2004
  • A surge counter is installed under surge arrester, which is protecting the power system apparatuses against abnormal voltage and surges originated in power system line. A surge counter is the device of knowing the times of surge flowed in. There are two methods to get the electric power for mechanical movement and detect the surge. One is using ZnO varistor resister and the other is using the current transformer. In this paper, the characteristics of these methods are presented with using the test and evaluation of them. The process of evaluating the characteristics is essential to develop the domestic surge counter.

  • PDF

전원용 SPD의 건전성 평가 장치 개발 (Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device)

  • 장석훈;김영진;김성주;김재형
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

An Ellerman bomb-associated surge observed by the FISS/NST

  • 양희수;채종철;김연한;조일현
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.88.1-88.1
    • /
    • 2012
  • We observed a surge associated with an Ellerman bomb using the Fast Imaging Solar Spectrograph(FISS) of the New Solar Telescope at Big Bear Solar Observatory. The surge was seen in absorption and varied rapidly both in H alpha and Ca II 8542 line. It originated from the Ellerman bomb, and was impulsively accelerated to 20km/s of the blueshift(upward) motion. Then the gradual change from blueshift of 20km/s to redshift of 40km/s occurred in 20 minutes. Based on the measured line-of-sight velocities, we estimated the material reached up to about 5,000km height. We inferred physical parameters of the surge by adopting the cloud model, and found that the temperature of the surge material was about 25,000K and the non-thermal velocity was about 10km/s. Our results suggest that the surge might be heated intensely after it was ejected from the Ellerman bomb.

  • PDF

배전피뢰기용 접지도선의 효과적인 설치기법 (Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors)

  • 이복희;강성만;유인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

서지전압에 의한 저압유도전동기의 절연평가 (Insulation Evaluation of Low-voltage Induction Motors by Surge Voltages)

  • 최수연;최재성;박대원;길경석;송재용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1892-1896
    • /
    • 2008
  • Inverter-fed induction motors (IFM) are prevalent in traction vehicles. However, the winding insulation of IFM is substantially more stressed than of line-powered motors by surge voltages. Consequently, the winding insulation of IFM should be estimated by surge voltages. Also, the weakness of coil insulation can be detected by the surge voltage test. This paper described the insulation evaluation of induction motors by application of surge voltages. A surge voltage generator with the maximum voltage of 5 kV and the selectable rise-time in ranges of $50\;ns\;{\sim}\;500\;ns$ was fabricated. In the experiment, we applied surge voltages into induction motors with the magnitude and the risetime according to IEEE 522. By the analysis of applied surge voltage and current waveforms, we could find difference between normal and defection windings.

  • PDF

배전계통에서 분기선로 형태에 따른 뇌서지 전달특성 해석 (Analysis of Propagation Characteristics of Lightning Surge according to the Type of Branch Line in Distribution System)

  • 서훈철;한준;김윤곤;김철환;최선규;이병성;이상봉
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1376-1382
    • /
    • 2013
  • This paper analyzes the propagation characteristics of lightning surge according to the type of branch line in distribution system. The types of branch line considered are H-type and PI-type. At each type, the length of main feeder is same, while the number and length of branch line are different. The distribution line is modeled and the various lightning locations are simulated by Electromagnetic Transient Program(EMTP). For each lightning, the various measuring points are selected. Based on the simulation results, the propagation characteristics of lightning surge at each measuring point are analyzed. The analyzed results are verified by travelling wave theory.

자동차 능동 현가장치 유압계 회귀 관로에서의 서지 압력 저감법 (Effective Smoothness of Surge Pressure Generated in the Return Line of Active Suspension Hydraulic System for Vehicle)

  • 정용길;이일영;윤영환
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.111-118
    • /
    • 1998
  • Surge pressure problem at the oil return line of the hydraulic circuit of an active suspension system for passenger cars was investigated by experiments and numerical analyses. In the numerical analyses, the method of characteristics was used for simulating unsteady flow in the hydraulic system and gas discrete model was adopted for estimating gas volume variation in separated liquid column. In the experiments and analyses, effects of the physical parameters of the accumlator on smoothing surge pressure was elucidated.

  • PDF

산업플랜트용 서지 측정 분석 장치 개발 (Development of the Surge Measurement System for Low Voltage Power Line of Industrial Plants)

  • 김영진;김재형;장석훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1698-1699
    • /
    • 2007
  • This paper deals with the surge measurement system for low voltage power line of industrial plants. It consists of a capacitive divider, A/D conversion part, signal processing and control part. A FPGA and a DSP board were designed to fast signal processing and control. Also, in order to measure lightning surge and switching surge for a long time, data backup device was applied by using SD memory. A performance of the measurement system was verified through evaluation test using impulse calibration generator.

  • PDF

345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토 (Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL)

  • 장화윤;이종범;김용갑;장태인
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.

가스절연송전선로의 서지특성 분석에 관한 연구 (A Study on Analysis of Surge Characteristics on Gas Insulated Transmission Lines)

  • 정채균;박흥석;강지원;장태인;윤종건;김양상;석광현;김형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.371_372
    • /
    • 2009
  • This paper describes surge characteristics on 345kV combined transmission system mixed overhead line and GIL(Gas Insulated Transmission Line). Then, it is compared with the results of the system mixed overhead line and XLPE power cables. Finally the lightning overvoltages are also discussed according to surge arrester installation in two kinds of combined transmission systems when the lighting strikes on the phase conductor.

  • PDF