• Title/Summary/Keyword: Surge analysis

Search Result 614, Processing Time 0.041 seconds

Analysis of lightning surge on the 345kV Gas Insulated Substation (345kV GIS 변전소 뇌써지 해석)

  • Kim, Jae-Kwan;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.561-563
    • /
    • 2003
  • This paper deals with simulation of lightning overvoltage generated by back flashover entering 345[kV] Gas Insulated Substation. In order to protect the substation equipment against lightning surge, insulation coordination is performed with the lightning arrester. This paper suggests optimal location of lightning arrester using the EMTP/ATPDraw to mere economically and effectively reduce the lightning surge incoming overhead lines.

  • PDF

Analysis on Induced Surge Voltage of Electric Car Line affected by Lightning in Rapid-Transit Railway System (고속철도시스템에서 낙뢰로 인해 전차선에 유도되는 서지전압의 해석)

  • Lee, Sung-Gyen;Lee, Kun-A;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.65-70
    • /
    • 2015
  • Lightning is one of hazards affecting the rapid-transit railway system. There are two effects, which are direct lightning surge to electric car line and induced lightning surge. Protection methods for the direct lightning surge are studied with various occasions, however, study of induced lightning surge is insufficient in spite of a large or small effects. In this paper, it is analysed the way that serge voltage is induced to electric car line by lightning strikes. By modeling the propagation process and the coupling phenomenon of electromagnetic wave produced by lightning strikes, it is achieved to make integrative circuit model combined with existing electric car model. The study is conducted into three different waveform of electromagnetic wave produced by lightning; rectangular wave, double exponential distribution wave, triangle wave. It is also simulated that the inducing serge is coupled to electric car line in an arbitrary location. The simulation results in that, when rapidly changing rectangular wave is supplied, maximum power is induced to electric car line.

Methodology for Risk Assessment for Exposure to Hurricane Conditions

  • Edge, Billy L.;Jung, Kwang-Hyo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.1
    • /
    • pp.37-49
    • /
    • 2012
  • An analysis of potential flooding by storm surge and wave run-up and overtopping can be used to evaluate protection afforded by the existing storm protection system. The analysis procedure can also be used to evaluate various protection alternatives for providing typhoon flood protection. To determine risk, the storm surges for both historical and hypothetical are compiled with tide conditions to represent high, slack and low water for neap, spring and mid range tides to use with the statistical procedure known as the Empirical Simulations Technique (EST). The EST uses the historic and hypothetical events to generate a large population of life-cycle databases that are used to compute mean value maximum storm surge elevation frequency relationships. The frequency-of-occurrence relationship is determined for all relevant locations along the shoreline at appropriate locations to identify the effect using the Empirical Storm Simulation (EST). To assist with understanding the process, an example is presented for a study of storm surge analysis for Freeport, Texas. This location is in the Gulf of Mexico and is subject to hurricanes and other tropical storms that approach from the Atlantic Ocean.

Seismic Performance Assessment of Atmospheric Surge Tank (노출형 조압수조의 해석모델별 내진성능평가)

  • Kim, Yongon;Ok, Seung-Yong;Kim, Il Gyu;Ryu, Seonho;Bae, Jungjoo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This study investigates the seismic performance of the surge tank which is of the atmospheric type and constructed above the ground. For that purpose, three different numerical models of the surge tank have been taken into account. Two models are constructed to describe the surge tank with different support conditions: one is to model all supports as fixed, and the other is to use spring element for the rock conditions. The third model is constructed to describe not only the surge tank with spring element of the rocks but also the vertical waterway tunnel. Through the time-history analysis of the surge tank subjected to three artificially excited ground motions, it is demonstrated that there can be much difference between the three models of our interest according to the support conditions and inclusion of the vertical waterway tunnel. However, their seismic performances still remain below the safety criteria, i.e., dynamic allowable stress. Also, the numerical results let us know where the critical sections occur. These results could be used to develop the efficient seismic enhancement method for the surge tank.

Typhoon-surge Characteristics in Relation with the Tide-surge Interaction (조석-해일 비선형성과 관련된 태풍-해일 특성)

  • Kang, Ju Whan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.1
    • /
    • pp.25-37
    • /
    • 2015
  • Tide-surge interaction during typhoon periods has been analyzed. The quantitative analysis of the Chi-square test shows that the interaction is most prominent at the Southwestern coast whereas the Western and the Southeastern regions are not. Patterns of surge type were divided into two groups, that is, steep type and mild type. Then, the interaction was turned out to be more prominent for mild type data. The weak interaction at the Western region is considered due to negative surges when the south-track typhoons attack. However, the interaction is remarkable when the west-track typhoons attack. The weak interaction at the Southeastern coast is, on the other hand, considered due to abundance of the steep type typhoons. Thus, inundation risk would be so apprehensive at that region because large-scale surge might be caused even at high tide.

Optimum design of direct spring loaded pressure relief valve in water distribution system using multi-objective genetic algorithm (다목적 유전자 알고리즘을 이용한 상수관망에서 스프링 서지 완화 밸브의 최적화)

  • Kim, Hyunjun;Baek, Dawon;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • Direct spring loaded pressure relief valve(DSLPRV) is a safety valve to relax surge pressure of the pipeline system. DSLPRV is one of widely used safety valves for its simplicity and efficiency. However, instability of the DSLPRV can caused by various reasons such as insufficient valve volume, natural vibration of the spring, etc. In order to improve reliability of DSLPRV, proper selection of design factors of DSLPRV is important. In this study, methodology for selecting design factors for DSLPRV was proposed. Dynamics of the DSLPRV disk was integrated into conventional 1D surge pressure analysis. Multi-objective genetic algorithm was also used to search optimum design factors for DSLPRV.

A Fluid Analysis for Propellant Feed System as Thruster Valve Operation (인공위성 추력기 작동에 따른 배관 내 유동해석)

  • Yu, Myoung-Jong;Kim, Su-Kyum;Lee, Kyun-Ho;Choi, Joon-Min
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.45-46
    • /
    • 2006
  • Usual LEO satellite for earth observation use a blowdown hydrazine monopropellant propulsion system for attitude hold and orbit maintenance. For precision control, thruster valve has very short closing time, but this can cause water hammering and pressure surge. Since water hammering and pressure surge can cause damage of propulsion system and ununiform thrust, Thruster valve closing is one of the special concern during satellite propulsion system design. In this paper, an analysis for propellant feed system is conducted using the method of characteristics. The results represent water hammer effect is negligible even at the worst case and pressure surge can be decreased effectively with a trim orifice.

  • PDF

A Study on the Field Test for Surge Analysis in Underground Distribution Systems (지중배전선로 서지해석의 실증적 연구)

  • Yun, Chang-Sub;Lee, Jong-Beom;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.701-702
    • /
    • 2007
  • This paper describes the modelling techniques for surge analysis in underground distribution systems with power cables. To evaluate the Analysis model, the change of line model and permittivity is considered. power cable parameters calculated by LCC of EMTP are considered to evaluate surge model in underground distribution systems. It is evaluated that impulse model according to the shape of impulse source model. However it is confirmed through comparison with measurement value in field test of underground distribution systems.

  • PDF

Emergences of LH Surge Affected by Different Progesterone Levels in Ovariectomized Goats (난소제거된 염소에서 Progesterone 농도의 영향에 의한 LH surge 분비에 미치는 영향)

  • Kim, Seung-Joon
    • Journal of Veterinary Clinics
    • /
    • v.31 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • The purpose of the present study was to determine the priming effects of progesterone that affect the emergence of LH surge mode secretion by three different progesterone levels. In previous studies, we have shown that LH surge occurred in follicular levels of progesterone, whereas there was no surge mode secretion of LH and FSH in either the subluteal or luteal levels of progesterone. In this study, the hypothesis was that the priming effects of progesterone on the timing of the LH surge induced by exogenous estradiol are same between subluteal and luteal levels of progesterone. Long-term ovariectomized Shiba goats that had received implants of estradiol capsules (Day 0) and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels. On Day 7, all devices of progesterone packets were removed but estradiol capsules were maintained during the experiment, and blood samples were collected at 1 hr interval for 12 h from the time of progesterone removals to determine peripheral changes of estradiol and progesterone concentration. Then all animals were infused estradiol on the Day 7 after 13 h from the removals of progesterone devices with a peristaltic pump into jugular vein at a rate of 3 ${\mu}g/h$ for 36 h. For analysis of peripheral LH and estradiol concentration, blood samples were collected via another jugular vein at 2 h intervals for 52 h (from 4 h before the start of estradiol infusion to 48 h after the start of estradiol infusion). In all animals of the three groups treated with estradiol infusion, an LH surge was expressed but the peak time of LH surge was different. This time interval from estradiol infusion until the peak of LH surge was gradually and significantly extended by the different levels of progesterone treated before estradiol infusions in the three groups.

Patterns of Pulsatile and Surge Modes of Follicle-Stimulating Hormone Treated with Different Progesterone Levels in Ovariectomized Goats (난소제거된 Shiba 염소에서 다른 농도의 Progesterone 처치에 의한 FSH Surge 및 Pulse 분비에 미치는 영향)

  • Kim, Seung-Joon;Tanaka, Tomomi;Kamomae, Hideo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.225-231
    • /
    • 2011
  • The objective of the present study was to determine the progesterone levels that effects on the pulsatile and surge modes of FSH secretion. In previous studies we have shown that LH surge occurred in the follicular levels of progesterone, whereas there was no surge mode secretion of LH in either the sub luteal or luteal levels of progesterone. LH pulsatile frequencies were high in two groups such as follicular level and sub luteal level. But in the luteal level of progesterone the pulsatile pattern of LH were strongly suppressed. Namely, sub luteal levels of progesterone, around 1 ng/ml, completely suppressed the LH surge but did not affect the pulsatile frequency of LH secretion. Because of this we hypothesized that the two secretory patterns of FSH are similar to that of LH. Long-term ovariectomized Shiba goats that had received implants of estradiol capsules and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels and at 10-min intervals for 8 h on Days 0, 3, and 7 (Day 0: just before progesterone treatment) for analysis of the pulsatile frequency of FSH secretion. Then estradiol was infused into the jugular vein of all animals at a rate of 3 ${\mu}/h$ for 16 h on Day 8 to determine whether an FSH surge was induced. Blood samples were collected every 2 h from 4 h before the start of the estradiol infusion until 48 h after the start of the infusion. In each group, the mean ${\pm}$ SEM concentration after progesterone implant treatment was 3.3 ${\pm}$ 0.1 ng/ml for the high P group, 1.1 ${\pm}$ 0.1 ng/ml for the low P group, and < 0.1 ng/ml for the non-P group, concentrations similar to the luteal levels, subluteal levels, and follicular phase levels of the normal estrous cycle, respectively. The FSH pulse frequency was maintained highly in all groups on Day 0, Day 3 and Day 7. An FSH surge was induced in all 4 cases of the Non-P group. In the High P and Low P groups, the plasma concentrations of FSH remained low until 48 h after the start of estradiol infusion, and no occurrence of FSH surge was found in any of the animals. The results of this study not only confirm that the pulsatile patterns of FSH were not inhibited strongly relative to LH, they also suggest that some other mechanism and factor may be controlling the FSH secretion.