• Title/Summary/Keyword: Surge analysis

Search Result 606, Processing Time 0.059 seconds

Comparative Study on Water Hammer for Pump Station in High Pressurized Pipes in Kuwait

  • Shim, Kyu Dae;Kang, Yong Suk;Choung, Joon Yeon;Abdellatif, Mohamed;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.265-269
    • /
    • 2017
  • Because of abrupt changes for velocity in water, transient flow is occurred in practical life. To reduce and avoid the high or low pressure of pipe network system, various surge protection facilities are used to prevent the risk in pipe network system. Especially, we focused on study not only preventing positive and negative pressure but also selecting adequate equipment for high pressurized pipelines. Several critical cases were considered by undertaking a steady state hydraulic study and transient dynamic simulation and we suggested that the surge vessel of various surge protection system was recommended to control high and low pressures on pipeline system in perspective.

  • PDF

Inundation Analysis Considering Water Waves and Storm Surge in the Coastal Zone (연안역에서 고파랑과 폭풍해일을 고려한 침수해석)

  • Kim, Do-Sam;Kim, Ji-Min;Lee, Gwang-Ho;Lee, Seong-Dae
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.35-41
    • /
    • 2007
  • In general, coastal damage is mostly occurred by the action of complex factors, like severe water waves. If the maximum storm surge height combines with high tide, severe water waves will overflow coastal structures. Consequently, it can be the cause of lost lives and severe property damage. In this study, using the numerical model, the storm surge was simulated to examine its fluctuation characteristics at the coast in front of Noksan industrial complex, Korea. Moreover, the shallow water wave is estimated by applying wind field, design water level considering storm surge height for typhoon Maemi to SWAN model. Under the condition of shallow water wave, obtained by the SWAN model, the wave overtopping rate for the dike in front of Noksan industrial complex is calculated a hydraulic model test. Finally, based on the calculated wave-overtopping rate, the inundation regime for Noksan industrial complex was predicted. And, numerically predicted inundation regimes and depths are compared with results in a field survey, and the results agree fairly well. Therefore, the inundation modelthis study is a useful tool for predicting inundation regime, due to the coastal flood of severe water wave.

A Study on the In-Pipe Surge Analysis for Cargo Unloading Piping System of LNG Carrier (LNG선의 화물 하역 배관망의 과도 응답 해석에 관한 연구)

  • Chun, Byung-Il;Woo, Jong-Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.124-134
    • /
    • 1996
  • In this paper the pressures and flowrate distributions in the loading/unloading piping system of LNG carrier have been investigated in the case of unsteady flow state as well as steady one. Under emergency situation the main cargo pumps are forced to fail, and the ESD(Emergency Shut Down) valves and Stop valves are closed within set-time. The surge pressures according to the variations of valve closing time have been computed to recognize the surge phenomenon due to sudden decrease of flowrate. By means of these analysis results, the most important factors on the in-pipe surge phenomenon of cargo loading/unloading piping system of LNG Carrier are the type of ESD and Stop valves, valve closing time, and the pipe arrangements.

  • PDF

Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL (345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토)

  • Jang, Hwa-Youn;Lee, Jong-Beom;Kim, Yong-Kap;Jang, Tae-In
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.

Frequency analysis of storm surge using Poisson-Generalized Pareto distribution (Poisson-Generalized Pareto 분포를 이용한 폭풍해일 빈도해석)

  • Kim, Tae-Jeong;Kwon, Hyun-Han;Shin, Young-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.173-185
    • /
    • 2019
  • The Korean Peninsula is considered as one of the most typhoon related disaster prone areas. In particular, the potential risk of flooding in coastal areas would be greater when storm surge and heavy rainfall occurred at the same time. In this context, understanding the mechanism of the interactions between them and estimating the risk associated with the concurrent occurrence are of particular interests especially in low-lying coastal areas. In this study, we developed a Poisson-Generalized Pareto (Poisson-GP) distribution based storm surge frequency analysis model to combine the occurrence of the exceedance of a threshold, that is the peaks over threshold (POT), within a Bayesian framework. The storm surge frequency analysis technique developed through this study might contribute to the improvement of disaster prevention technology related to storm surge in the coastal area.

Calculation of Probability of System Failure for Pipe Network with Surge Tank regarding Unsteady Flow (Surge Tank가 설치된 상수도관망에서 부정류를 고려한 불능확률 산정)

  • Kwon, Hyuk Jae;Lee, Cheol-Eung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2009
  • In the present study, a reliability analysis calculating the probability of system failure has been performed using cut set and results of numerical analysis for unsteady flow in pipe. Especially, the probability of system failure has been evaluated regarding the effect of valve closure which is a really important activity in operation of piping system. In spite of small amount of demand, it was found that fast valve closure can generate high probability of system failure. Furthermore, it was confirmed that surge tank can reduce the unsteady effects and probability of system failure in water distribution system. From the results, it was found that the unsteady flow has a significant effect on the probability of system failure Furthermore, it was able to find which pipe or cut set has high probability of system failure. So it could be used to determine which pipe or cut set has a priority of repair and replacement. Therefore, reliability analysis regarding unsteady flow has to be performed for the planning, designing, maintenance, and operation of piping system.

GIS Decision Support Modeling for Storm Surge Management (해일방재를 위한 GIS Decision Support Modeling)

  • 김수정;김승용;염재홍
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.435-440
    • /
    • 2004
  • Most of our GIS implementation activities have been focussed on the management of urban information in local municipalities. Management of urban facilities has been the major issue of concern and has little role in providing the decision maker with alternatives from which one can analyse and choose the optimum solution. For this reason, the spatial decision support system is in need. Business analysis software is effectively used for site analysis of new stores, customer prospecting and other issues of decision making for business purposes, The same geoprocessing module of business analysis software would be useful if put to use for the management of disaster management especially for storm surge management. Application of the business analysis model for disaster management has been reviewed. Specially in case of storm surge, where quick response is crucial, the spatial decision support system will be most effective.

  • PDF

Lightning Surge Analysis on Underground System in DC Combined Distribution System (DC 혼합배전시스템에서 지중계통의 뇌과전압 해석)

  • An, Chun-Yong;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.737-743
    • /
    • 2013
  • This paper describes the overvoltage through lightning surge analysis on underground system in DC combined distribution systems. It is considered that operating micro grid including distributed generation with smart grid can make possibility of composing new distribution system different from existing one. However, there are many papers about low voltage DC distribution in grids or buildings but not many about replacement or distributing 22.9kV AC distribution system to DC system. Among many research need for DC system development, overvoltage is studied in this paper. Overvoltage is simulated on DC cable when lightning strikes to overhead grounding wire which is installed at the nearest location from power cable section. Analysis as well as modeling is performed in EMTP/ATPDraw. It is evaluated that analysis results can be used to design of DC underground distribution power cable system.

Stress analysis and optimal design of surge-tank (Surge-Tank의 응력해석 및 최적설계)

  • 이수훈;지상현;김민수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.3-8
    • /
    • 1990
  • 본 고에서는 자동차의 냉각장치중, 냉각수를 저장하는 기능을 갖는 surge-tank의 내압에 의한 국부적인 균열 발생 방지 및 용기의 응력환화를 목적으로, 범용 구조해석 프로그램인 CAEDS의 여러 모듈(GEOMOD, GFEM, IFES, OPTISEN)을 이용하여 응력해석을 수행한 후, OPTISEN(최적화 해석 모듈)을 적용하여 용기 두께 및 보강재 위치에 따른 설계민감도를 구하여 최적 두께 및 보강재의 최적 위치를 구하였다.

  • PDF

Analysis of lightning surge on the 345kV Gas Insulated Substation (345kV GIS 변전소 뇌써지 해석)

  • Kim, Jae-Kwan;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.561-563
    • /
    • 2003
  • This paper deals with simulation of lightning overvoltage generated by back flashover entering 345[kV] Gas Insulated Substation. In order to protect the substation equipment against lightning surge, insulation coordination is performed with the lightning arrester. This paper suggests optimal location of lightning arrester using the EMTP/ATPDraw to mere economically and effectively reduce the lightning surge incoming overhead lines.

  • PDF