• Title/Summary/Keyword: Surge absorption

Search Result 18, Processing Time 0.025 seconds

A Study on the Performance Analysis of Photovoltaic System with Digital Surge Detection device

  • Byeong-Ho Jeong;Ju-Hoon Park
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.376-387
    • /
    • 2024
  • This paper examines the performance improvement of a photovoltaic power generation system with a surge protection function by applying a digital surge detection device for surge suppression in a direct current distribution panel applied to a photovoltaic power generation system. The main components used for surge protection are mainly SAD, MOV, and GTA components, and a digital surge detection device was additionally applied to this. Each component has advantages and disadvantages in terms of performance and functionality for surge protection, so a surge protection device with meaningful performance and functionality must be designed in a complex device structure that harmonizes the advantages and disadvantages of each component in order to construct a surge protection device with meaningful performance and function. Through empirical experiments, a performance analysis of a complex surge detection device to which a digital surge detection device is applied was conducted. As a result of the experiment, through absorption and blocking of surges detected through a digital surge detection device, it has both absorption and blocking performance for surges and exhibits surge absorption characteristics for hundreds of voltages in micro second. This performance showed a relatively stable state against surge noise compared to conventional devices, which produced an output waveform of stable quality in the inverter output waveform.

Characteristics and Change of Electrode Surface in Moisture Absorption on the Series Gap Surge Arrester (직렬 갭 피뢰기의 흡습시 전극표면의 변화 및 특성)

  • Cho, Han-Gu;Kim, Hyang-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1172-1175
    • /
    • 2003
  • The characteristics and change of electrode surface about Gap type surge arrester for protect DC subway rail were investigated with moisture absorption. Compared that tested about DC/AC discharge commencement voltage, residual voltage, Impulse, square wave impulse for DC rail surge arrester about Gap type surge arrester of moisture absorption state. The AC discharge commencement voltage acted greatly effect of moisture absorption than the DC discharge commencement voltage test.

  • PDF

Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics (전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

Fracture and Protection Technologies against Impulse of Power Arresters (전력용 피뢰기의 임펄스에 의한 파손과 대척 기술)

  • 한세원;조한구;김석수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF

Influence of $TiO_2$ Addition on Microstructure of ZnO Ceramic Varistor (ZnO 세라믹 바리스터의 미세구조에 미치는 $TiO_2$의 영향)

  • 소병문;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.214-220
    • /
    • 1998
  • ZnO varistors are characterized by the features of excellent nonlinearity and surge withstand capability. In this paper, in order to investigate the use of ZnO varistor as surge absorption device in low voltage, metal oxide material($TiO_2$) was selected as control material of grain growth. Samples of ZnO varistors were fabricated with varying the contents, and then the microstructures and V-I characteristics were measured. It was observed by SEM that the mean grain size increased with the increase of the additive. From the measurement of V-I characteristics, it was observed that according to the increase of the quantity of $TiO_2$ as additive, the operating voltage was lowered.

  • PDF

A Study on the Microstructral Uniformity and Surge Energy Capability of ZnO Varistor (ZnO 바리스터 미세조직 균일화와 새지 에너지 내량 향상에 관한 연구)

  • 한세원;조한구;서형권;정세영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.637-639
    • /
    • 1999
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, ZnO varistors are chosen by several electrical parameters according to their applications, namely 1mA DC voltage, 1eakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. But these Parameters have scattering properties due to the nonuniformity of electrical characteristics. In this study, the effect of the microstructrual nonuniformity on the surge absorption capability of ZnO varistors.

  • PDF

An Ellerman bomb-associated surge observed by the FISS/NST

  • Yang, Hee-Su;Chae, Jong-Chul;Kim, Yeon-Han;Cho, Il-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.88.1-88.1
    • /
    • 2012
  • We observed a surge associated with an Ellerman bomb using the Fast Imaging Solar Spectrograph(FISS) of the New Solar Telescope at Big Bear Solar Observatory. The surge was seen in absorption and varied rapidly both in H alpha and Ca II 8542 line. It originated from the Ellerman bomb, and was impulsively accelerated to 20km/s of the blueshift(upward) motion. Then the gradual change from blueshift of 20km/s to redshift of 40km/s occurred in 20 minutes. Based on the measured line-of-sight velocities, we estimated the material reached up to about 5,000km height. We inferred physical parameters of the surge by adopting the cloud model, and found that the temperature of the surge material was about 25,000K and the non-thermal velocity was about 10km/s. Our results suggest that the surge might be heated intensely after it was ejected from the Ellerman bomb.

  • PDF

Impulse Characteristics of MOV Elements for Railroad Vehicle Arrester (전철 탑재 피뢰기용 MOV 소자 임펄스 특성)

  • Han, S.W.;Cho, H.G.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1529-1531
    • /
    • 1999
  • The main functions of AC railroad vehicles arresters is to protect the main transformer from lightening impulse or switching impulse surge, then the MOV(metal oxide varistor) elements rated of 10kA is applied. The residual voltage and surge energy absorption are important parameters in designing arrester, these must be carefully decided with considering protecting level of impulse environment of system. The purpose of this study is to discuss the residual voltages and the energy absorption capability by impulse currents on MOV elements for railroad vehicles, and to introduce design factors which act as optimal protecting condition against impulse currents.

  • PDF

Effect on Household Absorption Chiller by the Supply of the Cooling Water (냉각수 보급이 가정용 흡수식 냉난방기의 성능에 미치는 영향)

  • 이호생;김동휘;최병권;김재돌;윤정인
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.267-272
    • /
    • 2002
  • The electric heat pump requiring HCFCs as a refrigerant has been for most residential air-conditioners in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes a serious problem to the global environment such as global warming and ozone layer destruction. An absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the absorption chiller/heater. Experiment was done with a 1.5RT household absorption chiller and heater. It was experimented that the cooling capacity, gas capacity, COP were researched by the temperature of cooling water. The change of the cooling water temperature have effect the temperature(or pressure) of the parts on absorption chiller The result of the change of the cooling water temperature have the effects of the absorption chillers. This data will help to operate the household absorption chiller and heater.

  • PDF

Experimental Study on Cavitation Instability of a Solution Pump Inducer in an Absorption Chiller-Heater (흡수식 냉온수기내 용액펌프 Inducer의 Cavitation 불안정성에 대한 실험적 연구)

  • Seo, Min;Lee, Kyung-Hoon;Kang, Shin-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2434-2439
    • /
    • 2008
  • This paper was studied on the cavitation instability of a Solution Pump Inducer in an absorption chiller-heater. Inlet pressure of LiBr and rotational speed at nominal mode are 2,800 Pa and 3,500 rpm respectively. Due to the marginal operation of available NPSH, the cavitation performance of the inducer is critical for the stable operation without the deterioration of head performance. In the study, cavitation performance and its mode of instability was investigated experimentally. Water was used as the working fluid and the test inducer was scaled up as 1.75 times for detail measurements and flow visualization. Inlet pressure was controlled by a vacuum pump. This research focused on types of cavitation instability and phenomena to investigate the possibility of harmful damage due to cavitation instability. Casing wall pressure and instantaneous inlet pressure was measured to observe the unsteady flow characteristics. Through the visualization and spectrum analysis of pressure, the occurrence region and intensity of asymmetric cavitation and cavitation surge are analyzed in the test inducer.

  • PDF