• 제목/요약/키워드: Surge Line

검색결과 260건 처리시간 0.033초

직격뢰 침입시 배전계통에서 선로 및 기기의 절연설계 (Insulation Design of Line and Equipment in Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2003
  • This paper examines the insulation coordination scheme of line and equipment in distribution system when the direct lightning surge strikes. The BIL that is applied in distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyse the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. Form these result, authors examine the rationality of BIL.

  • PDF

345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가 (Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL)

  • 장화윤;이종범;김용갑;정채균
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

지중송전케이블 뇌서지 유도현상 분석 (Analysis of Induced Lightning Surge Phenomena on Underground Power Cables)

  • 정채균;강연욱;강지원;김두진;김재승;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.578-579
    • /
    • 2011
  • This paper describes the analysis of induced lightning surge phenomena at underground power cables under construction when the lightning surge strikes at phase conductor of grounding wire of overhead line in service. Therefore, This paper proposes the optimal protection methods establishment against lightning surge induced from operating transmission.

  • PDF

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

지중배전케이블의 서어지 전파특성 실증연구 (A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests)

  • 이재봉;김병숙;박철배;정연하;한병성
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.118-125
    • /
    • 2007
  • 가공선로와 지중선로가 혼합된 배전계통에서 뇌서어지와 개폐서어지가 입상주를 통하여 유입될 수 있다. 이러한 서어지는 케이블을 따라서 이동하게 되고 케이블의 종단에서 반사된다. 이때 반사되는 서어지는 그 크기가 2배 정도가 되고 지중배전선로의 절연을 위협할 수 있다. 한전의 지중배전계통을 모의할 수 있는 모델계통을 만들고 이 계통에 서어지를 인가하여 케이블의 서어지 전파 특성을 측정하였다. 실제시험으로 측정한 결과를 EMTP 해석 결과와 비교하여 EMTP 파라미터들을 수정하였다. EMTP 해석에서 케이블 절연체의 유전율, 피뢰기의 특성곡선, 서어지의 파형을 조정하면 실증시험 결과와 거의 일치하는 결과를 얻을 수 있었으며, 케이블의 말단에서 2배 정도 전압상승이 되고 분기에 의하여 복잡하게 전파되는 것을 확인하였다.

지락고장에 의해 금속제 유연전선관에 유도된 개폐서지전압의 특성 (Characteristics of the Switching Surge Voltages Induced at Metal Flexible Conduits Due to Ground Faults)

  • 이복희;신건진;박희열;엄상현;김유하
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.74-80
    • /
    • 2013
  • This paper presents the transient behavior of the switching surge voltages generated by interruption of DC ground fault currents flowing through metal flexible conduits. All fault circuits consist of line parameters such as resistance, inductance, capacitance and conductance. The use of nonmagnetic metal conduits should be taken into account in order to reduce the inductance of battery charger distribution circuits. The frequency-dependent circuit parameters of metal flexible conduits were measured. The switching surge voltages generated at the ground fault circuit consisted of steel-galvanized alloy and aluminium conduits were investigated. As a result, the impedances of metal flexible conduits are significantly increased over the range of the frequency above 10 kHz and the switching surge voltages generated along aluminium flexible conduit are lower than those along steel-galvanized alloy conduit when DC fault current is interrupted.

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전의 타당성 평가 (Suitability Evaluation on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;이종범;김용갑;송일근;김병숙
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2135-2142
    • /
    • 2010
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as locations and current types of lightning stroke. Overvoltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

NCT 설계 및 특성 분석에 관한 연구 (A Study on the Design and Chracteristic Analysis for Noise Cut Transformer)

  • 이재복;허창수
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.146-154
    • /
    • 1998
  • 교류 전원선로에서 발생하는 수 kHz에서 수십 MHz에 이르는 광대역의 주파수특성올 가진 전원노이즈는 전기, 전자장비의 정상적인 동작에 많은 장해요소가 되고 있으며 이들 전도노이즈를 억제하기 위한 부품으로 현재 써어지 억제부품과 필터가 적용되고 있다. 그러나 기존의 대책부품은 전력공급선과 노이즈 피해회로를 전기적으로 완전히 절연시킬 수 없기 때문에 전도 노이즈 중에서 가장 크게 발생하는 공통모드 노이즈 억제성능이 제한 되고 있다. 본 논문에서는 절연변압기의 절연 특성에 정전 차폐를 추가함으로써 전도노이즈 및 써어지 억제기능이 우수한 NCf의 설계방법올 제시하였으며, 설계 제작된 1[kVA] NCT 시작품의 모의 등가회로에 대한 써어지 해석결과와 실험 측정 결과를 상호 비교하여 제안된 모델의 특성을 비교 평가하였다.

  • PDF