• 제목/요약/키워드: Surface-to-air

검색결과 4,867건 처리시간 0.032초

공기중 절연파괴에 있어서 전극표면의 요철에 의한 영향 (The Effect of Surface Roughness on Breakdown in Air)

  • 오철한;김미태
    • 전기의세계
    • /
    • 제28권11호
    • /
    • pp.33-36
    • /
    • 1979
  • In a uniform field, when an electrode with a hemispherical protrusion is set in atmosphere, by applying the streamer breakdown criterion and the surface roughness factor, the effect of field distortion due to electrode surface roughness on breakdown is investigated theoretically. A quantitative relation between the threshold of breakdown and the air pressure times the heigh of protrusion is derived by the aid of a computor and the results are compared with that of SF$_{6}$./.

  • PDF

액체 충돌제트의 표면조도변화에 따른 이상유동 열전달 특성 (Effect of Surface Roughness on Two-Phase Flow Heat Transfer by Confined Liquid Impinging Jet)

  • 임성환;신창환;조형희
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.714-721
    • /
    • 2005
  • The water jet impingement cooling with boiling is one of the techniques to remove heat from high heat flux equipments. The configuration of surface roughness is one obvious condition of affecting the performance on heat transfer in nucleate boiling, The present study investigates the water jet impinging single-phase convection and nucleate boiling heat transfer for the effect of surface roughness to enhance the heat transfer in free surface and submerged jet. The distributions of the averaged wall temperature as well as the boiling curves are discussed. Jet velocities are varied from 0.65 to 1.7 m/s. Surface roughness by sand blast and sand paper varies from 0.3 to 2.51 ${\mu}m$ and cavity shapes on surface are semi-circle and v-shape, respectively The results showed that higher velocity of the jet caused the boiling incipience to be delayed more. The incipient boiling and heat transfer increase with increasing surface roughness due to a large number of cavities of uniform size.

MODELING AND ANALYSIS ON THIN-FILM FLOW OVER A ROUGH ROTATING MAGNETIC DISK

  • Kim, Sung-Won;Moon, Byung-Moo
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.645-649
    • /
    • 1995
  • The depletion of thin liquid films due to the combined effect of centrifugation, surface roughness, and air-shear has recently been studied. While surface roughness of a rotating solid disk can be represented by deterministic cures, it has been argued that spatial random processes provide a more realistic description. Chiefly because of surface roughness, there is an asymptotic limit of retention of a thin film flowing on the rotating disk. The aim of this article is to model the depletion of thin-film flow and analyze the interplay of centrifugation, surface tension, viscosity, air-shear, disjoining pressure, and surface roughness that affect the depletion of the film. Also, the robustness of stochastic description of surface roughness is examined.

  • PDF

Numerical investigation of a novel device for bubble generation to reduce ship drag

  • Zhang, Jun;Yang, Shuo;Liu, Jing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.629-643
    • /
    • 2018
  • For a sailing ship, the frictional resistance exerted on the hull of ship is due to viscous effect of the fluid flow, which is proportional to the wetted area of the hull and moving speed of ship. This resistance can be reduced through air bubble lubrication to the hull. The traditional way of introducing air to the wetted hull consumes extra energy to retain stability of air layer or bubbles. It leads to lower reduction rate of the net frictional resistance. In the present paper, a novel air bubble lubrication technique proposed by Kumagai et al. (2014), the Winged Air Induction Pipe (WAIP) device with opening hole on the upper surface of the hydrofoil is numerically investigated. This device is able to naturally introduce air to be sandwiched between the wetted hull and water. Propulsion system efficiency can be therefore increased by employing the WAIP device to reduce frictional drag. In order to maximize the device performance and explore the underlying physics, parametric study is carried out numerically. Effects of submerged depth of the hydrofoil and properties of the opening holes on the upper surface of the hydrofoil are investigated. The results show that more holes are favourable to reduce frictional drag. 62.85% can be achieved by applying 4 number of holes.

핵비등열전달에 미치는 전열면표면조건의 영향 ('The Effect of Heating Surface Conditions on the Nucleate Boiling Heat Transfer')

  • 차지영;임장순;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제5권3호
    • /
    • pp.169-177
    • /
    • 1976
  • The importance of surface conditions of nucleate boiling is well recognized and it has been known that the heat transfer to boiling liquid is closely related to the bubble population density. The bubble population density should depend on various factors such as heat flux, surface roughness, surface contamination, properties of liquid, etc. In this paper the effect of surface conditions on heat transfer in nucleate boiling is treated. The experiments were carried out with distilled water boiler, on the horizontal heating surfaces, sintered with various bronze particle, under atmospheric pressure. In addition, experimental investigation for the polished bronze surface was performed. By studing a coefficient Xb defined by eq. (9), which represents the bubble foaming ability of heating surface, generalized fomula on the heat transfer in the nucleate toiling were expressed. The coefficient $X_b$, determined empirically, is not constant and indicates a major influence of the sintered metal surfaces on the $\Delta$, necessary to sustain nucleate boiling at any given heat flux. In this study, the main results are obtained as follows; (1) At low temperature difference, the coefficient $X_b$ of sintered metal surface was found to he higher than the polished surface throughout the full range of experiments. (2) The optimum sintered structure showing the maximum coefficient $X_b$ has been confirmed to exist and it is encountered when particle diameter is $256{\mu}$.

  • PDF

남극 브랜스필드 해협에서의 퇴적과정과 관련된 기후특성 (Climatic Characteristics Related with Sedimentary Process in Bransfield Strait, Antarctica)

  • 이방용;권태영;이정순;윤호일;윤영준
    • 지구물리
    • /
    • 제8권4호
    • /
    • pp.173-185
    • /
    • 2005
  • This study examines the relationships among sea ice concentration, surface air temperature, surface wind, and SST (Sea Surface Temperature) in Bransfield Strait to understand the climatic characteristics and its related sedimentary process there. In analyses of the monthly data, during the austral autumn (Mar., Apr., and May), the frequency of southeasterlies is correlated positively with the sea ice concentration and negatively with the surface air temperature, whereas that of northwesterlies is reverse. These relationships are explained by the process that the southeasterlies of the cold air from the Antarctic Continent affect the ocean current around Bransfield Strait. And then the ocean current makes the sea ice generated in the Weddell Sea drift into the strait. During the spring (Sep., Oct., and Nov.), sea ice concentration and surface air perature are closely correlated with the frequency of northwesterlies with warm air mass. In the some parts of the northern boundary region, the sea ice concentration in Bransfield Strait is positively correlated with the SST during the autumn and spring. Such relationship may rather propel the sea ice melting in proportion to the sea ice concentration during the autumn.

  • PDF

서울 도심지의 인본열에 의한 지표온도 분석: 위성영상 적용 사례 (Analysis of the Land Surface Temperature by the Anthropogenic Heat in the Urban Area of Seoul: An Example in Application of Satellite Images)

  • 방건준;박석순
    • 환경영향평가
    • /
    • 제19권4호
    • /
    • pp.397-407
    • /
    • 2010
  • The increase of the solar reradiation from urban areas relative to suburban due to urbanization heats up the air temperature in urban areas and this is called the urban heat island (UHI) effect. This UHI effect has a positive relationship with the degree of urbanization. Through the studies on UHI using the satellite imagery, the effect of the surface heat radiation was observed by verifying the relationship between the air temperature and the land cover types (surface materials such as urban, vegetation, etc.). In this study, however, the surface temperature distribution was studied in terms of land use types for Seoul. Using land use types, the surface temperature in urban areas such as residential, industrial, and commercial areas in Yeongdeungpo, highly packed with industrial and residential buildings, was maximum $6^{\circ}C$ higher than in the bare ground, which indicated that the surface temperature reflected the pattern of the human-consumed energy on the areas and showed that one of the important causes influencing the air temperature except the surface heat reradiation by the sun is the anthropogenic heat. Also, the effect due to the restoration of the Chunggae stream on UHI was investigated. The average surface temperature for the Chunggae stream was reduced about $0.4^{\circ}C$ after restoration. Considering that each satellite image pixel includes mixture of several materials such as concrete and asphalt, the average surface temperature might be much lower locally reducing UHI near the stream.

아파트 입면형 PV적용방식의 발전성능효과해석 연구 (A simulation analysis of PV application method effect on electric power performance in an apartment wall facade)

  • 서정훈;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.25-32
    • /
    • 2006
  • The objective of this study is to investigate the effect of building integrated PV application method on power generation. PV modules were integrated to a hypothetical apartment building facade in Seoul, Korea. Three different design options of PV panel mounted on exterior wall were developed for the analysis of cooling effects through ventilation. Numerical simulations using TRNSYS coupled with COMIS were executed to evaluate the design options. Their facade configurations are such as vertically installed PV panels with or without air gap between PV rear surface and exterior wall surface, and the tilted PV panels attached to the exterior wall at an angle of to the horizontal. Parametric results show that there is little difference regardless of the air 9ap width between PV rear surface and exterior wall surface. Special strategies which could effectively cool a PV panel to increase the electric power are required if we prefer to a vertical facade configuration in a building integrated PV installation. Consequently, it is expected that there is no reason for architect to install vertically PV panels with air gap unless active strategies are considered.

수중폭기용 노즐형 산기관 개발에 관한 실험적 연구 (Experimental Study on the Development of Nozzle-Type Diffusers for Submersible Aeration Process)

  • 임동렬;조남효
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.604-608
    • /
    • 2004
  • Experimental study was conducted to increase the oxygen transfer efficiency of air diffusers in clean water. By measuring the bubble size from the bubbly two-phase flow visualization with several air diffusers the size of air bubbles near the top surface of aeration tank seems to be independent on the diffuser types. Considering design parameters for the better breakup of larger bubbles around the air diffusers, advanced conceptual air diffusers using nozzle-type throat showing the higher oxygen transfer efficiencies were made.

  • PDF

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.