• 제목/요약/키워드: Surface-to-air

검색결과 4,867건 처리시간 0.036초

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • 대한원격탐사학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

온풍난방을 채용한 3연동 플라스틱 하우스의 실내공기용적 변화가 하우스 온열환경에 미치는 영향 (Influence on the Thermal Environment by Change of Indoor-air Volume of Plastic Greenhouse with Hot Air Heating Systems)

  • 전삼채;이창수;나수연;허종철;최동호
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.1-10
    • /
    • 2002
  • Relatively being economical in installation and easy in operation, hot-air heating system has been generally used in greenhouse for heating system regardless of high cost in maintenance and uneven distribution of air temperature. Therefore to overcome the disadvantages in maintenance and in distribution of air temperature and to improve efficiency of heating system, this experimental study is performed. This experimental study aims to improve the character of uneven temperature distribution in vertical direction and to reduce energy consumption for heating in a greenhouse. The experiment had been performed to investigate change of thermal environment and effects on reducing energy consumption for heating in greenhouse by additional surface insulation and reduction of indoor-air volume that come by installing transparent vinyl membranes with different height in each house. The results show that there is a wide difference in oil-energy consumption between houses according to condition of surface insulation and change of indoor-air volume. Furthermore, the results show that the efficiency of dual surface is higher than that of change of indoor-air volume in terms of energy saving.

Effects of Air Blast Thawing Combined with Infrared Radiation on Physical Properties of Pork

  • Hong, Geun-Pyo;Shim, Kook-Bo;Choi, Mi-Jung;Min, Sang-Gi
    • 한국축산식품학회지
    • /
    • 제29권3호
    • /
    • pp.302-309
    • /
    • 2009
  • This study investigated the effects of infrared (IR) radiation combined with air blast thawing on the physical properties of pork. Regardless of air velocity, increasing IR dosage produced an exponential increase in the thawing rate of pork. This rate increased further when air blast velocity was increased. IR treatments showed significantly lower thawing loss than that of 0 Watt treatment, while increasing air velocity significantly increased thawing loss of pork (p<0.05). Increasing both IR power and air velocity tended to decrease the cooking loss of pork. Moreover, increased IR power tended to decrease the water holding capacity and shear force of pork. The shear force changes were not significant (p>0.05). Shear force also increased with increasing air velocity. In addition, the higher the air velocity the higher the shear force of pork. In Commission Internationale de l'Eclairage (CIE) colour determination, control of temperature prevented discolouration from overheating of sample surface. The results suggest that IR dosage combined with air blast has potential in thawed meat quality aspects, and that humidity control could prevent surface drying.

The Effect of Aerated Oil Considering Live Oil Surface Tension on High-Speed Journal Bearing

  • Chun, Sang-Myung
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.103-113
    • /
    • 2001
  • The influence of aerated oil on high-speed journal bearing is examined by classical thermohydrodynamic lubrication theory coupled with analytical models for viscosity and density of air-oil mixture in fluid-film bearing. Convection to the walls and mixing with supply oil and re-circulating oil are considered. The live oil surface tension is considered as functions of temperature, API gravity and air volume ratio. With changing eccentricity ratio, it is investigated the effects of air bubbles on the performance of a high-speed plain journal bearing. Just at the moderate eccentricity ratios, even if the involved aeration levels are not so severe and the entrained air bubble sizes are not so small, it is found that the bearing load and friction farce may be changed so visibly for the high speed bearing operation.

  • PDF

수치시뮬레이션에 의한 공기부양선 주위의 유동장해석과 조파저항계산 (Numerical Analysis on Flow Fields and the Calculation of Wave Making Resistance about Air Supported Ships)

  • 나영인;이영길
    • 한국전산유체공학회지
    • /
    • 제1권1호
    • /
    • pp.55-63
    • /
    • 1996
  • Numerical computations are carried out to analyze the characteristics of flow fields around Air Supported Ships. The computations are performed in a rectangular grid system based on MAC(Marker And Cell) method. The governing equations are represented in finite difference forms by forward differencing in time and centered differencing in space except for its convection terms. For the certification of this numerical analysis method, the computations of flow fields around a Catamaran, an ACV(Air Cushion Vehicle) modeled with pressure distribution on free surface and two SES(Surface Effect Ship)'s are carried out, The results of the present computations are compared with the previously presented computational and experimental results in the same condition.

  • PDF

열교환기 핀에서의 서리층 물성치에 대한 실험 상관식 (Empirical Correlations of Frost Properties on the Fin of a Heat Exchanger)

  • 김경민;이관수
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.629-635
    • /
    • 2009
  • In this study, fin surface temperature and frost properties, i.e., frost thickness and frost surface temperature on a heat exchanger, were experimentally analyzed with different fin thicknesses, fin sizes and thermal conductivities of fin. As a result, it is found that fin thickness and thermal conductivity of fin should be considered in order to design an efficient heat exchanger fin. Correlations of dimensionless average frost properties were proposed as functions of dimensionless air temperature, dimensionless fin base temperature, dimensionless fin thickness, absolute air humidity, Reynolds number and Fourier number. The correlations predicted well the average frost thickness with a maximum error of 10.5% and frost surface temperature with a maximum difference of $0.89^{\circ}C$, respectively.

흡착보양재의 오염물질방출 저감성능에 관한 연구 (A study on contaminant reduction performance of the adsorption protector for construction surface)

  • 허정용;최창호;이윤규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.714-719
    • /
    • 2008
  • In a domestic construction field, after floor is constructed, protector for construction surface is set up to prevent the surface of the floor being scratched and polluted. However, the problem is that contaminants discharged with the removal of the protector for construction surface exert a bad influence for the indoor air quality. In the research, it tested to the contaminant reduction performance of the adsorption protector for construction surface using powder of charcoal by the alternative proposal of such protectors for construction surface

  • PDF

Dry Air/O2 혼합가스의 혼합비에 따른 절연파괴 및 연면방전 특성 연구 (A Study on Characteristics of Insulation Breakdown and Surface Discharge by the Mixing Ratio of Dry Air/O2 gas mixtures)

  • 석정후;백종현;임동영;배성우;김기채;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.49-57
    • /
    • 2015
  • This paper presents the discharge characteristics and economic feasibility of a Dry $Air/O_2$ and a $N_2/O_2$ mixture gas in order to review $SF_6$ alternative. From AC discharge experiment in an quasi-uniform field, it was found that the optimal $N_2/O_2$ mixing ratio which breakdown voltage and surface flashover voltage were the highest was 70/30 and that the pressure dependence on the breakdown voltage was higher than that of the surface flashover voltage in the Dry $Air/O_2$ and the $N_2/O_2$ mixture gas. The mixing ratio (70/30) and the tendency of the pressure dependence were described in detail based on physical factors (impact ionization coefficient, electron attachment coefficient, secondary electron emission coefficient) involved in discharge mechanism and a electron source, respectively. In addition, the performance insulation and the economic feasibility of the Dry $Air/O_2$ and the $N_2/O_2$ mixture gas were discussed so that Dry $Air/O_2$ mixture gaswas more suitable than $N_2/O_2$ mixture gas to the $SF_6$ alternative.

Cathode에 따른 휴대용 PEM 연료전지의 성능 변화 (Performance of the PEMFC for the mobile devices according to cathode)

  • 이세원;이강인;박민수;주종남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.550-553
    • /
    • 2008
  • In this paper, experiments of air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to the cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single cell and 6-cell stack were used in this experiments. The experimental results showed that the open type cathode flow field plate gave better performance for small size PEMFCs because the open type cathode plate allowed better air convection than the channel type cathode plate. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical slit cell. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, PEMFC generated more stable power in the mass transport loss region.

  • PDF

현열 플럭스 추정에 의한 대류 혼합층 고도의 산출 (Calculation of the Convective Mixed Layer by Estimation of Sensible Heat Flux)

  • 김용국
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.639-645
    • /
    • 1998
  • A Jump model was evaluated for the calculation of hourly mixing height and mean potential temperature within the height. The Sump model was modified for estimation of downward heat fluxes by mechanical convections and surface heat fluxes. The surface heat fluxes were estimated from routine weather data such as solar radiation and air temperature. Total of 8 upper-air data observed at 0000UTC and 0600UTC in Osan station during April 23 to 26, 1996 were analyzed, and compared to the model results in detail. The calculated mixing heights and potential temperatures within the height were comparable to the observations, but some differences were showed. The calculated mixing heights were generally higher than observations. And, when variations of wind directions were large, the large difference of potential temperature was occurred. From the results, it was important to note that vortical motions and advections of air masses would affect to the growth of the mixing height.

  • PDF