• Title/Summary/Keyword: Surface-derivatization

Search Result 14, Processing Time 0.024 seconds

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

Thermodynamic Studies on the Adsorption of 4-Octylphenol on Carboxen by GC/MS Analysis (GC/MS 분석에 의한 4-Octylphenol의 Carboxen 흡착에 대한 열역학적 연구)

  • Lee, Joon-Bae;Park, Woo-Yong;Shon, Shungkun;Jung, Ji Eun;Jeong, Yong Ae;Gong, Bokyoung;Kim, Yu-Na;Kwon, O-Seong;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.356-361
    • /
    • 2018
  • It is common to analyze volatile organic compound (VOC) or semi-VOC (SVOC) in a sample composed of a complex matrix consisting of multiple components such as bloods through a separation process. Adsorption is a physical phenomenon in which certain components accumulate on the surface of other phases. In order to overcome difficulties in the pretreatment process, an adsorption is frequently used. Solid phase microextraction (SPME) equipment with porous carbon carboxen (CAR) is an example of adsorption application. In this study, the adsorption of 4-octylphenol to carboxen was examined. To do so, the extraction efficiency for such solvents as dichloromethane ($CH_2Cl_2$, DCM), ethylacetate ($CH_3COOC_2H_5$, EA) and diethylether ($C_2H_5OC_2H_5$, $Et_2O$) was studied and also the derivatization reaction for 4-octylphenol with reagents of bistrimethylsilyltrifluoroacetamide (BSTFA), methylchloroformate (MCF) and pentafluorobenzylbromide (PFBBr) was compared. The combination of DCM and BSTFA showed good performance thus they were adopted for this study. Thermodynamic adsorption experiments showed that the adsorption process was endothermic and Freundlich isotherm equation was more suitable than Langmuir isotherm. It was also found that the adsorption followed a pseudo-$2^{nd}$ order kinetic model.

Quantitative Determination of Phenol in Water Using GC-MS after Liquid-Liquid Extraction and Acetylation (액-액 추출과 아세틸화 후 GC-MS를 이용한 물 중 phenol의 분석)

  • Park, Sunyoung;Kim, Yunjeong;Jung, Sungjin;Kim, Hekap
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.1
    • /
    • pp.63-66
    • /
    • 2017
  • BACKGROUND: The phenol concentrations in water samples were determined using gas chromatography after derivatization of the analyte to phenyl acetate followed by extraction using a large volume of solvent. However, this procedure requires an additional purification step and is not analytically efficient. METHODS AND RESULTS: In this study, phenol was first extracted from an acidified water sample using ethyl acetate and then acetylated using acetic anhydride in the presence of a small amount of water and $K_2CO_3$. The derivative was extracted using 1mL of n-butyl acetate. One microliter of the extract was analyzed by GC-MS without further purification. The calibration curve showed good linearity with the $r^2$ value of 0.9968. The method detection limit and the limit of quantitation were estimated to be $0.18{\mu}g/L$ and $0.56{\mu}g/L$, respectively. Repeatability (RSD, n=3) and recovery (n=3) were 9.1%-4.3% and 90.6%-110.5%, respectively. The concentrations of phenol in a few samples of stream water were distributed in the range of $2.51-7.51{\mu}g/L$. CONCLUSION: This method is simpler and faster to implement than those currently utilized and shows high analytical reliability. It can be applied to the quantitative determination of phenol concentrations in surface water and groundwater samples.

A study on Aflatoxins Analysis in The Herb Medicines (한약재 중 아플라톡신 분석에 관한 연구)

  • Lee, Sung-Deuk;Kim, Yeon-Sun;Kim, Nam-Hoon;Jung, Hee-Jung;Jung, Sam-Joo;Kim, Hwa-Soon;Kim, Kyung-Sik;Han, Ki-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.424-434
    • /
    • 2011
  • The increase in the consumption of herb medicines have made their use a public health problem due to the potential fungal contamination and the risk of the presence of my cot ox ins. 360 samples of herb medicines were evaluated for the aflatoxin contamination. The natural occurrence of aflatoxins in these samples were determined using immunoaffinity column clean up and high performance liquid chromatography (HPLC) with post-column derivatization. For samples analyzed, mean levels (incidence) of AFB1, AFB2, AFG1 and AFG2 in positive samples were $1.4\;{\mu}g/kg$(46.4%), $0.4\;{\mu}g/kg$(25.4%), $1.1\;{\mu}g/kg$(37.8%) and $0.9\;{\mu}g/kg$(24.3%), respectively. Recoveries of the full analytical procedure were 71.7~99.7% for AFB1, 88.1~99.2% for AFB2, 82.8~95.5% for AFG1 and 77.9~90.0% for AFG2. The excess cancer risk estimated using the cancer potency of aflatoxin B1 (7 $(mg/kg/day)^{-1}$ for $HBsAg^-$ and 230 $(mg/kg/day)^{-1}$ for $HBsAg^+$) were $1.30{\times}10^{-5}{\sim}1.22{\times}10^{-7}$ for hepatits B surface antigen negative ($HBsAg^-$) and $3.31{\times}10^{-4}{\sim}3.12{\times}10^{-6}$ for hepatits B surface antigen positive ($HBsAg^+$) respectively. In conclusion, although the contamination levels of samples used in the study were low, further actions are also required to undertake a program of herbal surveys in order to access mycotoxin contamination overall so that the safety of public will be protected.