• 제목/요약/키워드: Surface-active element

검색결과 61건 처리시간 0.024초

Hole and Pillar Patterned Si Absorbers for Solar Cells

  • Kim, Joondong;Kim, Hyunyub;Kim, Hyunki;Park, Jangho
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.226-226
    • /
    • 2013
  • Si is a dominant solar material, which is the second most abundant element in the earth giving a benefit in the aspect in cost with low toxicity. However, the inherent limit of Si has an indirect band gap of 1.1 eV resulting in the limited optical absorption. Therefore, a critical issue has been raised to increase the utilization of the incident light into the Si absorber. The enhancement of light absorption is a crucial to improve the performances and thus relieves the cost burden of Si photovoltaics. For the optical aspect, an efficient design of a front surface, where the incident light comes in, has been intensively investigated to improve the performance of photon absorption. Lambertian light trapping can be attained when the light active surface is ideally rough to increase the optical length by about 50 compared to a planar substrate. This suggests that an efficient design may reduce thickness of the Si absorber from the conventional 100~300 ${\mu}m$ to less than 3 ${\mu}m$. Theoretically, a hole-array structure satisfies an equivalent efficiency of c-Si with only one-twelfth mass and one-sixth thickness. Various approaches have been applied to improve the incident light utilization in a Si absorber using textured structures, periodic gratings, photonic crystals, and nanorod arrays. We have designed hole and pillar structured Si absorbers. Four-different Si absorbers have been simultaneously fabricated on an identical Si wafer with hole arrays or pillar arrays at a fixed depth of 2 ${\mu}m$. We have found that the significant enhanced solar cell performances both for the hole arrayed and pillar arrayed Si absorbers compared to that of a planar Si wafer resulting from the effective improvement in the quantum efficiencies.

  • PDF

수직하중에 의한 응력이 CMP 공정의 디싱에 미치는 영향 (Investigation of the Relationship Between Dishing and Mechanical Stress During CMP Process )

  • 김형구;김승현;김민우;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.30-34
    • /
    • 2023
  • Since dishing in the CMP process is a major factor that hinders the uniformity of the semiconductor thin film, many studies have focused this issue to improve the non-uniformity of the film due to dishing. In the metal layer, the dishing mainly occurs in the central part of the metal due to a difference in a selection ratio between the metal and the dielectric, thereby generating a step on the surface of the metal layer. Factors that cause dishing include the shape of the thin film, the chemical reaction of the slurry, thermal deformation, and the rotational speed of the pad and head, and dishing occurs due to complex interactions between them. This study analyzed the stress generated on the metal layer surface in the CMP process using ANSYS software, a commercial structure analysis program. The stress caused by the vertical load applied from the pad was analyzed by changing the area density and line width of the dummy metal. As a result of the analysis, the stress in the active region decreased as the pattern density and line width of the dummy metal increased, and it was verified that it was valid compared with the previous study that studied the dishing according to the dummy pattern density and line width of the metal layer. In conclusion, it was confirmed that there is a relationship between dishing and normal stress.

  • PDF

AlN 세라믹스와 금속간 계면접합에 관한 연구 : I. AlN/Cu 및 AlN/W 활성금속브레이징 접합체의 잔류응력 해석 (A Study on the Interfacial Bonding in AlN Ceramics/Metals Joints: I. Residual Stress Analysis of AlN/Cu and AlN/W Joints Produced by Active-Metal Brazing)

  • 박성계;이승해;김지순;유희;염영진
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.962-969
    • /
    • 1999
  • Ag-Cu-Ti 삽입금속을 이용하여 제조된 AlN/Cu와 AlN/W 활성금속브레이징 접합체의 잔류응력을 유한요소법으로 탄성 및 탄소성 해석을 행하여 그 결과를 접합강도 측정 결과와 파단 거동 관찰 결과와 비교, 분석하였다. 최대 잔류 주응력의 크기는 AlN/W 접합체보다 모재간 열팽창계수 차이가 큰 AlN/Cu 접합체에서 더 크게 나타났으며, 접합계면에 인접한 AlN 세라믹스 자유표면에 인장 성분의 응력집중이 확인되었다. 모재와 삽입금속의 탄소성 변형을 모두 고려할 경우, AlN/Cu 접합체의 경우 연질의 삽입금속에 의해 최대 잔류 주응력이 감소하여 소성변형에 의한 응력완화 효과가 있음을 확인하였으나, 100$\mu\textrm{m}$ 이상으로 삽입금속 두께를 증가시키더라도 잔류 주응력의 크기는 더 이상 크게 감소하지 않았다. 측정된 최대 접합강도는 AlN/Cu와 AlN/W 접합체에서 각각 52 MPa와 108 MPa이었으며, 파단 형태는 AlN/Cu 접합체는 AlN 자유표면으로부터 AlN 내부로 큰 각도를 이루면 진행되는 돔형의 파단이, AlN/W 접합체에서는 접합계면의 삽입금속층을 따라 AlN 측에서 파단이 일어나는 형태를 보였다.

  • PDF

지진 시 파괴면을 고려한 중력식 안벽의 영구변위 평가 (Estimation of Permanent Displacement of Gravity Quay Wall Considering Failure Surface under Seismic Loading)

  • 한인숙;안재광;박두희;권오순
    • 한국지반공학회논문집
    • /
    • 제35권4호
    • /
    • pp.15-26
    • /
    • 2019
  • 지진에 대한 중력식 안벽의 안정성은 구조물의 허용변위를 기준으로 평가하며, 외력으로 발생하는 변위를 계산하기 위하여 Newmark 활동블록 이론에 기초한 변위 경험식 혹은 수치해석을 사용한다. 수치해석의 경우 복잡한 지형 및 구조물에 대한 정밀한 분석이 가능하나 적절한 입력변수 및 환경설정의 어려움으로 전문가가 아니면 신뢰성 있는 결과 도출에 한계가 있다. Newmark 법의 변위 경험식은 지진파만을 가지고 영구변위를 추정하기에 수치해석보다 간편하여 널리 사용되고 있다. 하지만 변위 경험식들은 구조물의 특성과 활동면에 대한 파라메터가 없으며, 강체로 가정된 활동면에서 흙의 비선형 거동과 구조물과의 상호작용을 고려하지 않았다. 따라서 중력식 안벽의 지진 안정성 평가를 위해서는 앞서 언급한 한계점을 보완하는 새로운 변위 경험식이 필요하다. 본 연구에서는 수치해석을 통해 구조물 뒷채움재의 응답특성을 분석하여 최적의 활동면 산정법을 제시하고자 하였다. 이를 위해 유한요소해석을 수행하여 다양한 지진파에 따른 응답특성과 응력-변형률 관계를 분석하였다. 그 결과 뒷채움재의 응답특성과 활동면은 입력 지진파에 따라 달라지는 것으로 나타났다.

가시광 활성 WO3-TiO2 복합체 광촉매의 제조 및 이의 특성 평가 (Preparation of WO3-TiO2 Photocatalyst and Evaluation of Its Photo-activity in the Visible Light Range)

  • 여인철;강인철
    • 한국분말재료학회지
    • /
    • 제20권6호
    • /
    • pp.474-478
    • /
    • 2013
  • The most general photocatalyst, $TiO_2$ and $WO_3$, are acknowledged to be ineffective in range of visible light. Therefore, many efforts have been directed at improving their activity such as: band-gap narrowing with non-metal element doping and making composites with high specific surface area to effectively separate electrons and holes. In this paper, the method was introduced to prepare a photo-active catalyst to visible irradiation by making a mixture with $TiO_2$ and $WO_3$. In the $TiO_2-WO_3$ composite, $WO_3$ absorbs visible light creating excited electrons and holes while some of the excited electrons move to $TiO_2$ and the holes remain in $WO_3$. This charge separation reduces electron-hole recombination resulting in an enhancement of photocatalytic activity. Added Ag plays the role of electron acceptor, retarding the recombination rate of excited electrons and holes. In making a mixture of $TiO_2-WO_3$ composite, the mixing route affects the photocatalytic activity. The planetary ball-mill method is more effective than magnetic stirring route, owing to a more effective dispersion of aggregated powders. The volume ratio of $TiO_2(4)$ and $WO_3(6)$ shows the most effective photocatalytic activity in the range of visible light in the view point of effective separation of electrons and holes.

계면활성제 수용액에 의해 재생된 활성탄 촉매의 탈질 성능 ($DeNO_{x}$ Performance of Activated Carbon Catalysts Regenerated by Surfactant Solution)

  • 박혜민;박영권;전종기
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.739-744
    • /
    • 2011
  • 선택적환원 반응용 활성탄 촉매는 액정디스플레이 제조 공정에서 배출되는 붕소를 포함하는 배가스 중의 $NO_x$를 제거하는데 사용되는데, 붕소가 촉매의 세공을 막거나 활성점에 침적되어 촉매 비활성화가 발생하게 된다. 폐촉매는 다양한 계면활성제를 포함하는 수용액 중에서의 세정, 건조 및 소성에 의해 재생이 가능하였다. 세정 과정의 조건, 계면 활성제 종류, 소성 조건 등을 변화시키면서 재생 전과 후의 폐촉매의 물리화학적 성능 비교를 위하여 질소 흡착 실험, ICP에 의한 원소 분석을 수행하였다. 암모니아를 사용하는 선택적환원 반응은 고정층 촉매 반응기를 사용하여 $120^{\circ}C$에서 수행하였다. $90^{\circ}C$의 수용액에서 비이온 계면활성제를 사용하여 세정하고, 질소 분위기에서 $550^{\circ}C$에서 소성하여 재생한 활성탄 촉매는 붕소가 가장 많이 제거되어 신규 활성탄과 유사한 수준의 표면적과 $NO_x$ 제거 효율을 회복하였다.

이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법 (Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array)

  • 김강식;한호산;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.351-364
    • /
    • 2002
  • 일차원 어레이 변환자를 기계적으로 움직여 3차원 영상을 얻는 기존의 3차원 초음파 영상 기법은 일차원 배열 변환기가 갖는 고도방향 해상도의 저하를 극복하기 어렵다. 한편 이차원 위상 어레이 변환자를 이용하는 실시간 3차원 영상 시스템은 많은 수의 채널 수를 가지기 때문에 고비용의 매우 큰 빔집속부를 필요로 한다. 이러한 문제점을 극복하기 위해 본 논문에서는 2차원 곡면 어레이 상에서 256 채널의 송수신 부구경을 전기적으로 움직이면서 관심영역의 입체영상을 얻을 수 있는 3차원 영상화 기법을 제안하였다. 이를 위해 본 논문에서는 상용 3차원 영상 장치에 사용되는 기계 주사식 일차원 곡면 어레이 변환자와 측방향과 고도방향으로 동일한 시야각을 갖는 이차원 곡면 어레이 변환자를 설계하였다. 또한 제안된 방법에서는 256 개의 제한된 채널 수를 이용하면서도 송수신 부구경의 크기를 증가시켜 보다 향상된 해상도의 영상을 구현하기 위해 직사각형 모양의 부구경에서 네 모서리 부분의 어레이 소자들을 적절히 제거한 형태의 부구경을 사용하였다. 특히 수신시는 고도방향이나 측방향으로한 배열 소자씩 건너뛰는 희박 어레이 기법을 적용하여 수신 부구경의 크기를 증가시켰다. 또한 수신시 희박 어레이로 인한 소자간의 간격 증가로 인해 유발되는 그레이팅 로브 상승을 억제하기 위해 송신시에는 희박 어레이를 적용하지 않고 폴드-오버 어레이 기법을 적용함으로써 송신부구경의 크기를 측방향과 고도방향으로 각각 두배만큼 증가시키는 효과를 얻었다. 제안한 방법을 통해 기존의 기계 주사식 일차원 어레이 변환자를 이용한 실시간 3차원 시스템과 비교하여 측방향으로는 거의 같고 고도방향으로는 훨씬 우수한 해상도의 영상을 획득할 수 있음을 컴퓨터 모사실험을 통해 검증하였다.

전기비저항 토모그래피에 의한 지하구조의 3차원 영상화 (Three-dimensional Imaging of Subsurface Structures by Resistivity Tomography)

  • 이명종;김정호;정승환;서정희
    • 지구물리와물리탐사
    • /
    • 제5권4호
    • /
    • pp.236-249
    • /
    • 2002
  • 본 연구에서는 종래의 지표 전기비저항 탐사자료의 3차원 영상화 알고리듬을 확장하여 여러 시추공을 이용한 3차원 전기비저항 토모그래피 영상화 알고리듬을 개발하였다. 개발된 알고리듬은 유한요소법을 이용한 3차원 전기비저항 모델링과 최소자승 역산 알고리듬으로 구성되며, 역산의 분해능을 높이기 위하여 ACB(Active Constraint Balancing)법을 채용하였다. 수치모형실험 및 분해능 분석을 통하여 3차원 전기비저항 토모그래피가 효용성이 높은 탐사법임을 알 수 있었으며, 지하구조에 대한 고분해능의 입체 영상을 획득할 수 있는 방법임을 입증하였다. 또한, 전기비저항 토모그래피에서 지형효과를 정확히 반영함으로써, 영상의 왜곡을 배제하여 더욱 정확한 지하구조 영상을 획득할 수 있었다. 현장자료에 대한 적용성 검토를 위하여 화강암 석산지역에서 획득한 3차원 탐사자료에 3차원 전기비저항 토모그래피를 수행한 결과 신뢰도 높은 3차원 전기비저항 영상을 획득할 수 있었다.

AlN 세라믹스와 금속간 계면접합에 관한 연구: II. AlN/Cu 접합체의 잔류응력에 미치는 Mo 중간재의 영향 (A Study on the Interfacial Bonding between AlN Ceramics and Metals: II. Effect of Mo Interlayer on the Residual Stress of AlN/Cu Joint)

  • 박성계;김지순;유희;염영진;권영순
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.970-977
    • /
    • 1999
  • 활성금속브레이징법으로 계면접합된 AlN/Cu 접합체의 잔류응력 완화에 미치는 Mo 중간재의 영향을 조사하였다. 유한요소법에 의한 응력 해석과 접합체 강도 측정, 파단면의 관찰을 행하였으며, 이들 결과를 비교, 분석하였다. 응력 해석 결과로부터, Mo 중간재를 사용할 경우 최대 잔류 주응력이 형성되는 위치가 AlN/삽입금속 계면으로부터 삽임금속/Mo 계면을 통하여 Mo 내부로 이동됨을 확인하였다.접합체의 자유표면에 형성되는 인장성분의 응력집중 위치는 Mo 중간재 두께가 증가됨에 따라 Cu/Mo 계면과 Mo/AlN 계면의 두 곳으로 분리되었으며, AlN측 잔류응력의 크기는 크게 감소하였다. 중간재를 사용하지 않은 경우 최대 접합강도가 52 MPa로 낮은 강도를 보였으나, 두께 400$\mu\textrm{m}$ 이상의 Mo 중간재를 사용한 접합체의 경우, 200 MPa 이상, 최대 275 MPa의 접합강도를 얻을 수 있었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF