• Title/Summary/Keyword: Surface wind speed in Korea

Search Result 243, Processing Time 0.026 seconds

Air Quality Modeling of Ozone Concentration According to the Roughness Length on the Complex Terrain (복잡지형에서의 지표면 거칠기에 따른 오존 농도 수치모의)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Sung, Kyoung-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.430-439
    • /
    • 2007
  • The objective of this work is the air quality modeling according to the practical roughness length using the building information as surface boundary conditions. As accurate wind and temperature field are required to produce realistic urban air quality modeling, comparative simulations by various roughness length are discussed. The prognostic meteorological fields and air quality field over complex areas of Seoul, Korea are generated by the PSU/NCAR mesoscale model (MM5) and the Third Generation Community Multi-scale Air Quality Modeling System (Models-3/CMAQ), respectively. The simulated $O_3$ concentration on complex terrain and their interactions with the weak synoptic flow had relatively strong effects by the roughness length. A comparison of the three meteorological fields of respective roughness length reveals substantial localized differences in surface temperature and wind folds. Under these conditions, the ascended mixing height and weakened wind speed at night which induced the stable boundary stronger, and the difference of simulated $O_3$ concentration is $2{\sim}6\;ppb$.

Estimation of Standard Load for Disaster-Resistant Design of Outdoor Signboards (내재해형 옥외광고물 설계를 위한 표준하중 산정)

  • Lee, Sungsu;Kim, Junyeong;Ham, Hee Jung;Kim, Ji Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2016
  • Recent destructions of outdoor signboards have frequently been caused by strong wind, resulting in damage on the property and human livelihood. One of the major causes of the problems is inadequate implementation of structural design code to the outdoor signboards which are vulnerable to wind. This leads to this paper to present the design guideline of wind-resistant outdoor signboards. In order to estimate the design wind speed, basic wind speeds over Korea suggested by KBC(2015)(revision) are corrected with land surface roughness and topography of the terrain and installation height of the signboard. This paper also suggested the procedure of wind load estimation for different types of outdoor signboards; wall attached type, wall ribbed type and ground erected type. Since the process involves complex calculation to some extent, this paper presents summarized version of wind load estimation from non-professional point of view.

Anti-icing Method of Heated Walkway in Ice Class Ships: Efficiency Verification of CNT-based Surface Heating Element Method Through Numerical Analysis

  • Woo-Jin Park;Dong-Su Park;Mun-Beom Shin;Young-Kyo Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.215-224
    • /
    • 2023
  • While melting glaciers due to global warming have facilitated the development of polar routes, Arctic vessels require reliable anti-icing methods to prevent hull icing. Currently, the existing anti-icing method, i.e., the heating coil method, has disadvantages, such as disconnection and power inefficiency. Therefore, a carbon nanotube-based surface heating element method was developed to address these limitations. In this study, the numerical analysis of the surface heating element method was performed using ANSYS. The numerical analysis included conjugate heat transfer and computational fluid dynamics to consider the conduction solids and the effects of wind speed and temperature in cold environments. The numerical analysis method of the surface heating element method was validated by comparing the experimental results of the heating coil method with the numerical analysis results (under the -30 ℃ conditions). The surface heating element method demonstrated significantly higher efficiency, ranging from 56.65-80.17%, depending on the conditions compared to the heating coil method. Moreover, even under extreme environmental conditions (-45 ℃), the surface heating element method satisfied anti-icing requirements. The surface heating element method is more efficient and economical than the heating coil method. However, proper heat flux calculation for environmental conditions is required to prevent excessive design.

Sensorless Control Algorithm of a Surface Mounted PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 표면부착형 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han-Sol;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • PM synchronous motor may be rotated to an arbitrary direction and speed by outside wind under natural condition in cases where the fan is applied outside, such as in vehicle radiators and outdoor air-conditioners. Sensorless controls that cannot detect rotor position requires additional sensorless control algorithm because a rotor is rotated by an external load. In this study, the sensorless control of a PM synchronous motor under naturally rotating condition is proposed. The natural rotation conditions are classified as forward high-speed rotation, reverse high-speed rotation, and low-speed rotation. Experiment results verify the performance of the sensorless control, including the rotor speed and position detection at natural rotation mode and switch to the closed-loop sensorless control.

Development of a Ginseng Surface Washing System (인삼 표면세척 시스템 개발)

  • Lee, Hyun-Seok;Jeong, Jin-Woong;Kim, Byeong-Sam;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.541-548
    • /
    • 2009
  • We developed a surface washing system for ginseng. The washing system was developed using different treatments and conditions and characterized in terms of product hardness, weight loss, and change in temperature and color. Optimal results were obtained using a surface washing system involving a washing conveyor speed of 1.0 L/min, a water pressure of $35\;kg/cm^2$, a washing nozzle angle of $40^{\circ}$, a washing height of 5 cm, a 1-sec reciprocating washing nozzle cycle, a dehydration wind velocity of 30 m/sec, and an internal drying temperature of $30-33^{\circ}C$. A surface washing system using a washing conveyor speed of0.8 L/min, a water pressure of $40\;kg/cm^2$, a washing nozzle angle of $40^{\circ}$, a washing height of 3 cm, a 1-sec reciprocating washing nozzle cycle, a dehydration wind velocity of 30 m/sec, and an internal drying temperature of $30-33^{\circ}C$ resulted in ginseng that was stained yellow.

Characteristic for Long-term Trends of Temperature in the Korean Waters (한국 연근해 수온의 시공간적 장기변동 특성)

  • Seong, Ki-Tack;Hwang, Jae-Dong;Han, In-Seong;Go, Woo-Jin;Suh, Young-Sang;Lee, Jae-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.4
    • /
    • pp.353-360
    • /
    • 2010
  • The result of analysis of the observed temperature data by the Serial Oceanography Investigation of National Fisheries Research and Development Institute (NFRDI) during last 41 years from 1969 to 2008 showed that sea surface temperatures in the East, West and South Sea of Korea were clearly increased. In case of 100m depth, temperature was increased in the South Sea of Korea, but it was decreased in the East Sea. Especially, the temperature around the coastal area in the East Sea was significantly decreased by the spatial distribution of long-term change of temperature on 100m depth. It should lead to the decreasing trend in the long-term change of temperature on 100 m depth in the entire East Sea. The increasing trend was clearly larger in wintertime than in summertime by a factor of about 2 It means that the long-term increasing trend of sea surface temperature in the Korean Waters is usually caused by the distinctive increasing trend in wintertime. As the results of the analysis of air temperature and wind speed on the 6stations around the coastal area in the Korean Waters, air temperature was found to be continuously increased, but wind speed to be gradually decreased in winter. The weakness of vertical mixing by decreasing of wind speed caused to make the surface mixed layer shallow. it could be considered that the increasing trend of surface temperature was caused by weak mixing between surface and intermediate layers.

Application of Superfluid Shock Tube Facility to experiment of High Reynolds number flow (초유동 충격파관 장치의 고레이놀즈수 유동실험에의 응용)

  • ;H. Nagai;Y. Ueta;K. Yanaka;M. Murakami
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.27-30
    • /
    • 2002
  • The particle velocity in superfluid helium (He II) induced by a gas dynamic shock wave impingement onto He II free surface were studied experimentally by using Schlieren visualization method with an ultra-high speed video camera. It is found form visualization results that a dark zone in the immediate vicinity of the vapor-He II interface region is formed because of the high compressibility of He II and is developed toward bulk He II with the flowing-down speed of the vapor-He II interface. The mass velocity behind a transmitted compression shock wave that is equal to the contraction speed of He II amounts to 10 m/sec, the Reynolds number of which reaches $10^{7}$. This fact suggests that the superfluid shock tube facility can be applied to an experimental facility for high Reynols number flow as an alternative to the superfluid wind tunnel.

  • PDF

Comparison of Sea Surface Temperature from Oceanic Buoys and Satellite Microwave Measurements in the Western Coastal Region of Korean Peninsula (한반도 서해 연안 해역에서의 해양 부이 관측 수온과 위성 마이크로파 관측 해수면온도의 비교)

  • Kim, Hee-Young;Park, Kyung-Ae
    • Journal of the Korean earth science society
    • /
    • v.39 no.6
    • /
    • pp.555-567
    • /
    • 2018
  • In order to identify the characteristics of sea surface temperature (SST) differences between microwave SST from GCOM-W1/AMSR2 and in-situ measurements in the western coast of Korea, a total of 6,457 collocated matchup data were produced using the in-situ temperature measurements from marine buoy stations (Deokjeokdo, Chilbaldo, and Oeyeondo) from July 2012 to December 2017. The accuracy of satellite microwave SSTs was presented by comparing the ocean buoy data of Deokjeokdo, Chilbaldo, and Oeyeondo stations with the AMSR2 SST data more than five years. The SST differences between the microwave SST and the in-situ temperature measurements showed some dependence on environmental factors, such as wind speed and water temperature. The AMSR2 SSTs were tended to be higher than the in-situ temperature measurements during the daytime when the wind speed was low ($<6ms^{-1}$). On the other hand, they showed positive deviation increasingly as the wind speed increased for nighttime. In addition, increasing tendency of SST differences was related to decreasing sensitivity of microwave sensors at low temperatures and data contamination by land. A monthly analysis of the SST difference showed that unlike the previous trend, which was known to be the largest in winter when strong winds were blowing, the SST difference was largest in summer in Deokjeokdo and Chilbaldo buoy stations. This seemed to be induced by differential tidal mixing at the collocated matchup points. This study presented problems and limitations of the use of microwave SSTs with high contribution to the SST composites in the western coastal region off the Korean peninsula.

Power Law Exponent in Coastal Area of Northeastern Jeju Island for the Investigation of Wind Resource (풍력자원 조사를 위한 제주 북동부 연안역의 멱지수 분석)

  • Moon, Seo Jeong;Ko, Jung Woo;Lee, Byung Gul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 2013
  • Wind shear means the variation of wind speed according to the height. Wind shear is the important factor affecting the energy production of wind turbines. Power Law is used to extrapolate wind speed data. Normally, a Power Law exponent of 0.143 is used and this is referred to as the 1/7th Power Law. The Power Law exponent is affected by atmospheric stability and surface roughness of the site. Thus, it is necessary to calculate the Power Law exponent of the site exactly for an accurate estimation of wind energy. In this study, wind resources were measured at the three Met-masts which were located in the coastal area of northeastern Jeju Island. The Power Law exponents of the sites were calculated and proposed using measured data. They were 0.141 at Handong, 0.138 at Pyeongdae, and 0.1254 at Udo. We compared annual energy productions which are calculated using a Power Law exponent of 0.143, the proposed value of the Power Law exponents for each site, and the measured data. As a result, the cases of calculating using the proposed values were more similar to the cases using the measured data than the cases using the 0.143 value. Finally, we found that the propsed values of the Power Law exponent are available to more accurately estimate wind resources.

The Plastic Cracking Properties of Fly Ash Concrete with Various Curing Conditions (양생조건에 따른 플라이애쉬 콘크리트의 소성수축균열 특성)

  • Nam, Jae-Hyun;Park, Jong-Hwa
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.91-98
    • /
    • 2007
  • In this study, the property and plastic cracking pattern of concrete were compared and analyzed with the replacement ratio of fly ash 0, 5, 10, 15, 20% by cement weight. And curing conditions of concrete were given variously such as indoors(with wind speed as 0, 300, 500m/min), outdoors and chamber. The hydration temperature had a tendency to decrease as the replacement ratio of fly ash increased, and in the case of the wind speed 0m/min, it was showed that the moment that the amount of evaporation of water from surface of reference concrete was more than the volume of bleeding was 90 min since casting concrete. The time that the crack initiated had a tendency to be more quickly as the replacement ratio of fly ash increased. The number, length, width and area of crack in the indoor curing, exposed outdoor curing, enclosed outdoor curing had a tendency to decrease as the replacement ratio of fly ash increased. The crack had a tendency to decrease in sequence of exposed outdoor, enclosed outdoor curing, indoors curing. The outbreak of cracking by the change of temperature and humidity was affected by relative humidity more than temperature and the cracking had a tendency to increase as relative humidity lowered.