• 제목/요약/키워드: Surface treatment system

검색결과 1,227건 처리시간 0.026초

라미네이팅 필름의 코로나 처리 효과와 주사 전자현미경을 이용한 해석 (The Effect of Corona Treated on Laminating Film and Its Analytical Study by SEM)

  • 김종규;김양평
    • 한국인쇄학회지
    • /
    • 제26권2호
    • /
    • pp.15-30
    • /
    • 2008
  • Studies were carried out the phenomenal observation on the effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of experiments. These are as follow: 1) In order to verify the treatment reducing value of dynes and dynes durability with the lapse of time, it was checked dynes of a pair of 4 bar discharge electrode with 9 one for 144 hr., and it show results that 9 bar discharge electrode has higher initial dynes as well as keep up 48 dynes durability long than 4 one. 2) Drawn an inference from 3 actions -Chemical-Physical-Mechanical, on laminating film in terms of SEM's observation that are the adhesive status in boundary of corona treated base film, extrusion coating hotmelt layer, and configuration of hotmelt surface after corona treated. In tandem system, EVA layers adhesion keep its stability without corona discharge treatment.

  • PDF

다한증 환자에서 양극탐침을 이용한 허리교감신경의 고주파열응고술 -증례 보고- (Lumbar Sympathetic Radiofrequency Thermocoagulation Using Bipolar Probe in the Hyperhidrosis Patient -A case report-)

  • 이지현;김대원;심우석
    • The Korean Journal of Pain
    • /
    • 제18권1호
    • /
    • pp.92-95
    • /
    • 2005
  • Primary hyperhidrosis, a disorder of unknown etiology, is characterized by excessive uncontrollable sweating, most often of the palm surface of the hands, armpits, groin and feet. To decrease the symptoms of hyperhidrosis, drug therapy, iontophoresis, excision of axillary sweat glands and thoracoscopic sympathectomy have been attempted. A lumbar sympathectomy is one of the available choices for the treatment hyperhidrosis of the lower extremities. A 28-year old female patient presented with excessive sweating of her hands and feet. For the treatment of her foot hyperhidrosis, a bipolar radiofrequency ablation system was used to ablate the lumbar sympathetic ganglion, with a successful result. This modality will receive greater attention as an available alternative to lumbar sympathetic neurolysis.

Investigation on the Off Design Performance of a Transonic Compressor with Circumferential Grooves

  • Zhu, Jianhong;Piao, Ying;Zhou, Jianxing;Qi, Xingming
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.66-71
    • /
    • 2008
  • Two cases with circumferential grooves were designed for a transonic compressor, and 3-D numerical simulations were conducted for stall mechanism at three representative speeds. A conclusion can be drawn from the comparison between compressors with or without casing treatment that: with the rising of rotation speed, stall margin increases dramatically under the help of casing treatments, and the case with middle grooves has reasonable compromise between stall margin increment and efficiency cutting. At lower speed, the increment reduces, and grooves at the back of blade tip have more influence on stall margin. Further investigation shows there is a transition in mechanism of compressor stall with the decline of rotational speed: at high rotation speed, the expansion of stall margin mainly results from the suppression of tip leakage vortex by casing treatments, yet it benefits more from the depression of boundary layer separation from suction surface of blade tip.

  • PDF

Study on removal of microplastics using magnetic separation

  • Ueda, Reo;Akiyama, Yoko;Manabe, Yuichiro;Sato, Fuminobu
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.12-18
    • /
    • 2022
  • In recent years, the impact of microplastics (MPs) on ecosystems is a serious problem. Since MPs are difficult to recover once they are dispersed into the environment, it is important to remove them at the source. We proposed a magnetic separation of primary MPs (plastics manufactured in minute sizes) sized 10-100 ㎛ that has not been removed in the sewage process, based on the magnetic seeding process. In this study, we used magnetite as a magnetic seeding agent, and conducted magnetic separation experiments in the continuous process using a superconducting solenoidal magnet to investigate the feasibility of practical magnetic separation system of MPs. As a result, 85% separation rate was obtained by continuous separation using high gradient magnetic separation (HGMS) with hydrophobically treated magnetite as a magnetic seeding agent.

유·무기 전도성 물질을 함유한 UV 경화형 다층 코팅의 대전방지 특성 (Antistatic Behavior of UV-curable Multilayer Coating Containing Organic and Inorganic Conducting Materials)

  • 김화숙;김현경;김양배;홍진후
    • 접착 및 계면
    • /
    • 제3권3호
    • /
    • pp.22-29
    • /
    • 2002
  • 하층에 유 무기 전도성 물질을 코팅하고 상층은 다관능성 아크릴레이트를 코팅한 다층코팅의 자외선 경화형 시스템을 도입하였다. 이러한 다층코팅은 투명한 PMMA, PC, PET 등의 기재 위에 wet and wet 방식의 코팅 방법을 사용하여 제조하였다. 도막의 표면저항과 물성은 상층 두께의 변화와 상대 습도를 다르게 하여 측정하였다. 상층두께가 $10{\mu}m$ 이하일 때 $10^8{\sim}10^{10}{\Omega}/cm^2$의 표면저항을 나타냈으며 표면 물성은 단층코팅에 비해서 다층코팅이 더 우수하게 나타났다. 그리고 다층코팅에서의 도판트 이동효과는 접촉각과 FT-IR/ATR을 통해 관찰하였다. 하층이 무기 전도성 물질인 경우에는 관찰되지 않는 도판트(DBSA)의 필름-기재 계면에서 필름-공기 계면 쪽으로 이행되는 거동이 유기전도성 물질인 경우에는 관찰되었다.

  • PDF

저압 막여과 혼성공정을 이용한 고도 정수처리 (Low Pressure Hybrid Membrane Processes for Drinking Water Treatment)

  • 추광호;정지현;박학순
    • 멤브레인
    • /
    • 제17권3호
    • /
    • pp.161-173
    • /
    • 2007
  • 현재 막여과 공정은 정수처리에서 많은 관심을 받고 있다. 그러나 막여과 공정은 저압 운전이 가능한 정밀/한외여과 분리막을 이용할 때는 효과적인 용존성 유기물 제거가 이루어지지 않으며 막오염 현상으로 분리막의 투과도 감소가 일어난다. 고압 분리막을 이용할 경우 양질의 수질은 얻을 수 있으나 고압 운전으로 인하여 운전비용의 소모가 높다. 따라서 최근 분리막의 효율적인 정수처리 적용과 성능 향상을 위해서 다른 물리화학적 공정과 결합한 혼성공정에 대한 다양한 접근이 이루어지고 있다. 본 연구에서는 혼성공정으로 응집, 흡착, 특정 화학반응, 막표면 코팅 등과 정밀/한외여과 공정을 결합한 경우의 특징, 처리효율, 고려사항 등을 고찰하였다.

전자선 및 자외선 경화형 방무코팅용 모노머의 합성 및 물성비교 (Synthesis and Comparison of EB- and UV-curable Monomers for Anti-fogging Coatings)

  • 조정대;이재성;김양배;홍진후
    • 공업화학
    • /
    • 제16권3호
    • /
    • pp.449-455
    • /
    • 2005
  • 분자 내에 방무기능을 부여하기 위한 수산기와 전자선(EB) 및 자외선(UV) 경화가 가능한 아크릴레이트 관능기를 갖는 1관능성 및 4관능성 방무제 AF-1과 AF-2를 합성하여 EB 및 UV 경화시스템에 적용하였다. 합성된 AF-1과 AF-2를 UV 경화시스템에 적용하여 도막의 방무특성 및 경화물성을 측정한 결과, AF-1과 AF-2 함량을 5:17.5의 비로 함유한 배합이 표면과 내부경도, 내화학성 및 접착력이 저하되지 않으면서 김서림 방지 특성이 우수한 최적배합임을 알 수 있었다. 이 최적배합을 EB 경화시스템에 적용하였고, EB 및 UV 두 시스템에 의해 이루어진 코팅배합물을 PC sheet에 코팅하여 도막의 방무특성 및 경화물성을 비교 연구하였다. 그 결과 EB 및 UV에 의해 경화된 두 시스템 모두 우수한 방무특성을 나타냈으나 EB 시스템이 UV 시스템보다 더우수한 내부경도, 접착력 및 젖음성을 나타냄을 확인하였다.

Non-Chrome Magni 565 코팅 피막의 특성과 내식성 (Corrosion Resistance of Non-Chrome Magni 565 Coating and Characteristics of Its Coating Film)

  • 김상수;김무길;정병호;문명준
    • 열처리공학회지
    • /
    • 제19권4호
    • /
    • pp.200-207
    • /
    • 2006
  • In addition to the basic properties of the base and top coating agents, corrosion resistance of non-chrome magni 565 coating and characteristics of coating film when coated to steel substrate were studied. The system had a good wettability at room temperature. Moreover, both the contact angle and surface tension were affected little by the viscosity of coating agent and surface roughness of the steel substrate. And the samples coated with optimal conditions showed a great corrosion resistance in salt spray test with 1500 hours or longer of initial appearance time of rust. The coating film was composed of overlapping layer of zinc and aluminium flakes, and the thickness of base coat increased with an increase of base coat viscosity. Based on the C-F peaks of 1,1-Difluoroethaen homo-polymer, it was thought that the base coat was an inorganic polymer bond layer. Meanwhile, the top coat showed C-F peaks of polytetrafluoroethylene with C-H peaks of phenol in FT-IR analysis. From the lower weight loss of base coat in TG analysis, it was thought that cross linking density of base coat was larger than that of top coat. It was thought that the small exothermic reactions observed in DSC curves were due to the thermosetting resins contained in the coating agents. Compared to the non-coated specimen, the coated sample showed more higher polarization resistance and corrosion potential with lower corrosion current density.

족부 족관절 골좌상에서 자기공명영상 분류에 따른 통증의 호전 (Improvement of Pain according to Magnetic Resonance Imaging Classification in Bone Contusion around Foot and Ankle)

  • 김형직;이광복
    • 대한족부족관절학회지
    • /
    • 제23권4호
    • /
    • pp.183-188
    • /
    • 2019
  • Purpose: Bone contusion is usually treated with conservative therapy for 3 months. Bone contusion around knee and hip joints has been extensively reported on, but there are scant reports on this condition in foot and ankle joints. This study evaluated the nature, characteristics and location of bone contusion around foot and ankle joints to enlighten clinicians on how to better treat this disease entity. Materials and Methods: We classified bone contusion of the 76 patients into three types (102 sites; 47 ankle sprains, 18 traffic accidents, 11 falls) according to the Costa-Paz system with employing magnetic resonance imaging (MRI), and the study then analyzed the common sites and areas of occurrence according to the mechanism of injury and duration of pain after first conducting conservative therapy. Results: Of the 76 patients (102 sites) on the MRI, 43 case (42.2%) for talus, 19 cases for distal tibia, and 12 cases for calcaneus were involved. The classification, according to the Costa-Paz system, was Type I, 51 cases; Type II, 32 cases; and Type III, 19 cases. The duration of pain after conservative treatment was 12.15±2.17 weeks for Type I, 14.5±2.15 weeks for Type II, and 21.0±3.8 weeks for Type III. Conclusion: The most common location of post-traumatic bone contusion around both the foot and ankle is the talus, distal tibia, and calcaneus. The most common type of injury noted on MRI is a diffuse signal with change of the medullary component (Type I), In cases of bone contusion extending to a subjacent articular surface or disruption or depression of the normal contour of the cortical surface (Types II, III), the patients' pain appears to last longer. Thus, it is necessary to consider a longer period of conservative treatment in cases of Types II and III bone contusion because the patients' pain may last longer than 3 months.

신양천 하천수정화 연못시스템의 처리수준 및 연못반응 (Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.