• Title/Summary/Keyword: Surface mesh

Search Result 800, Processing Time 0.03 seconds

Effect of Endothelial Cell Growth Factor and Cyclic AMP Increasers on the Proliferation of Human Omental Microvascular Endothelial Cells (사람의 대망미세혈관내피세포 증식에 대한 내피세포성장인자 및 CYCLIC AMP 증가물질의 효과)

  • Kim, Won-Gon;Kim, Jong-Man;Yu, Se-Yeong
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.463-470
    • /
    • 1995
  • Complete prelining of artificial vascular grafts with autologous endothelial cells may be one of the ideal solutions to obtain a nonthrombogenlc blood-contacting surface. To establish an intact endothelial cell monolayer on a prosthetic surface at the time of implantation,a sufficient number of endothelial cells and adequate propagation condition In cell culture are prerequisites. In this experimental study, endothelial cells from microvessels of adult human oriental adipose tissue were enzymatically harvested, and optimal culture conditions for proliferation of the endothelial cells in cell culture were examined. Human oriental adipose tissue was digested with collagenase and endothelial cells were separated from other stromal elements by mesh filtration method. Cultured cells were identified as endothelial cells by immunofluorescent staining for factor VIII-related antigen. Proliferation in usual 20% fetal bovine serum (FBS) medium or medium containing endothelial cell growth factor (ECGF)(5 ng/ml) and heparin (HEP)(1,000 units/ml) were compared,and the effects of adding compounds that increase intracellular cyclic adenosine monophosphate levels, that is,cholera toxin (CT)(1 $\mu\textrm{g}$/ml) and isobutylmethylxanthine (IBMX)(0.2 ml),were also analyzed. In total,following eight media groups were examined. 1) FBS medium + ECGF + HEP, 2) FBS medium + ECGF + HEP+CT, 3) FBS medium+ECGF+HEP+lBMX, 4) FBS medium+ECGF+HEP+CT+ IBMX, 5) FBSmedium, 6) FBS medium +CT, 7) FBS medium + IBMX, 8) FBS medium + CT + IBMX. It was shown that the medium containing ECGF + HEP with or without cholera toxin was most efficient in Stimulating cell proliferation. IBMX was considered to have antagonistic effect to ECGF. Among experimental groups without ECGF and HEP, the addition of cholera toxin and IBMX was shown to significantly potentiate cell proliferation. This results could provide a practical method for use of cultured human endothelial cells for endothelial cell seeding of cardiovascular prosthetic device, particularly in small-diameter vascular grafts.

  • PDF

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

A Comparative Study about Industrial Structure Feature between TL Carriers and LTL Carriers (구역화물운송업과 노선화물운송업의 산업구조 특성 비교)

  • 민승기
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.1
    • /
    • pp.101-114
    • /
    • 2001
  • Transportation enterprises should maintain constant and qualitative operation. Thus, in short period, transportation enterprises don't change supply in accordance with demand. In the result, transportation enterprises don't reduce operation in spite of management deficit at will. In freight transportation type, less-than-truckload(LTL) has more relation with above transportation feature than truckload(TL) does. Because freight transportation supply of TL is more flexible than that of LTL in correspondence of freight transportation demand. Relating to above mention, it appears that shortage of road and freight terminal of LTL is larger than that of TL. Especially in road and freight terminal comparison, shortage of freight terminal is larger than that of road. Shortage of road is the largest in 1990, and improved after-ward. But shortage of freight terminal is serious lately. So freight terminal needs more expansion than road, and shows better investment condition than road. Freight terminal expansion brings road expansion in LTL, on the contrary, freight terminal expansion substitutes freight terminal for road in TL. In transportation revenue, freight terminal's contribution to LTL is larger than that to TL. However, when we adjust quasi-fixed factor - road and freight terminal - to optimal level in the long run, in TL, diseconomies of scale becomes large, but in LTL, economies of scale becomes large. Consequently, it is necessary for TL to make counterplans to activate management of small size enterprises and owner drivers. And LTL should make use of economies of scale by solving the problem, such as nonprofit route, excess of rental freight handling of office, insufficiency of freight terminal, shortage of driver, and unpreparedness of freight insurance.

  • PDF

Comparative Study on the Methodology of Motor Vehicle Emission Calculation by Using Real-Time Traffic Volume in the Kangnam-Gu (자동차 대기오염물질 산정 방법론 설정에 관한 비교 연구 (강남구의 실시간 교통량 자료를 이용하여))

  • 박성규;김신도;이영인
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.4
    • /
    • pp.35-47
    • /
    • 2001
  • Traffic represents one of the largest sources of primary air pollutants in urban area. As a consequence. numerous abatement strategies are being pursued to decrease the ambient concentration of pollutants. A characteristic of most of the these strategies is a requirement for accurate data on both the quantity and spatial distribution of emissions to air in the form of an atmospheric emission inventory database. In the case of traffic pollution, such an inventory must be compiled using activity statistics and emission factors for vehicle types. The majority of inventories are compiled using passive data from either surveys or transportation models and by their very nature tend to be out-of-date by the time they are compiled. The study of current trends are towards integrating urban traffic control systems and assessments of the environmental effects of motor vehicles. In this study, a methodology of motor vehicle emission calculation by using real-time traffic data was studied. A methodology for estimating emissions of CO at a test area in Seoul. Traffic data, which are required on a street-by-street basis, is obtained from induction loops of traffic control system. It was calculated speed-related mass of CO emission from traffic tail pipe of data from traffic system, and parameters are considered, volume, composition, average velocity, link length. And, the result was compared with that of a method of emission calculation by VKT(Vehicle Kilometer Travelled) of vehicles of category.

  • PDF

THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT (백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현)

  • Bae, Sung-Real;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.699-716
    • /
    • 1998
  • This study was designed to evaluate the expression of non-collagenous protein in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for osteonectin and osteocalcin. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats) and 6 experimental groups(24 rats) where 75g of force was applied from helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. And the tissues of a control group and experimental groups were studied immunohistochemically and histologically. The results were as follows : 1. Until 28 days after force application, periodontal fibers had been strectched on tension side and compressed in pressure side of all the experimental groups, and the arrangement of periodontal fibers had not been recovered yet. 2. The expression of osteonectin in control group was rare in dentin, cementum and osteocyte, and was mild in odontoblasts and matrix of alveolar bone. 3. The expression of osteocalcin in control group was negative in gingiva, osteoblasts, osteocyte and cementum, and was rare in predentin, capillaries in pulp and periodontal ligament and the matrix of alveolar bone. 4. There was no difference in the expression of osteocalcin or osteonectin in dentin, cementum, pulp, odontoblasts, between of control and of experimental groups. 5. The expression of osteonectin in intermaxillary suture got the peak in 7-day and was declined after 14-day. The expression of osteocalcin remained in a same degree since it became mild in 14-day. 6. The expression of osteonectin in pressure side of periodontal ligament of experimental group was rare, which was similar to control group. But in tension side, it was increased until 14-day aftrer which it was declined. 7. The expression of osteocalcin in periodntal ligament was rare in 12-hour to 14-day, but became severe in 28-day, which was greater in tension side than in pressure side, and in the periodontal fiber next to alveolar bone than to tooth surface. 8. The expression of osteocalcin in alveolar bone was rare until 14-day in pressure side, but became moderate in 28-day. The expression of osteonectin was increased from 7-day by time dependency, which was greater in tension side than in pressure side.

  • PDF

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Intermediate Culture of the Spat of Arkshell, Scapharca broughtonii in Summer (피조개, Scapharca broughtonii 부착치패의 하계 중간양성)

  • Min, Kwang-Sik;Kim, Byoung-Hak;Lee, Seung-Ju;Park, Ki-Yeol;Kim, Byung-Goun
    • The Korean Journal of Malacology
    • /
    • v.20 no.2
    • /
    • pp.125-130
    • /
    • 2004
  • Arkshell, Scapharca broughtonii spats were placed in natural environmental condition for 30 days from July 28 to August 27, 2004, in order to estabilish intermediate culture technique. Growth and survival of the spats in different intermediate culture areas with various culture methods were measured. Water temperature of studied area ranged from 24.1 to 28.5$^{\circ}C$, salinity was 15.4 to 33.3 psu, dissolved oxygen was 3.92 to 12.6 mg/l. Scapharca broughtonii spats cultured in Yeosu developed the best, 10.15 ${\pm}$ 1.12 mm in average shell length, and the highest survival was recorded as 77% in Namhae. Shell lengths of the Scapharca broughtonii spats cultured in the water depths of 2, 5, and 10 m were 7.14 ${\pm}$ 1.14 mm, 6.98 ${\pm}$ 1.74 mm and 6.27 ${\pm}$ 1.33 mm, and the survivals showed 75.5%, 77.0% and 76.5%, respectively. When 1 mm, 2 mm, and 3 mm-sized spats were cultured for 30 days in water depth of 5 m, the shell length increased to 6.73 ${\pm}$ 1.46 mm, 6.98 ${\pm}$ 1.74 mm and 7.04 ${\pm}$ 1.19 mm, and survivals were 67.0%, 77.0% and 58.5%, respectively. The shell lengths of spat cultured for 30 days in mesh sizes of 1 ${\times}$ 1 mm, 2 ${\times}$ 2 mm and 3 ${\times}$ 3 mm, 5 m below the surface were 8.14 ${\pm}$1.23 mm, 8.26 ${\pm}$ 1.19 mm and 8.78 ${\pm}$ 1.16 mm, and survivals were 41.5%, 43.0% and 44.5%, respectively.

  • PDF

A Relative Study of 3D Digital Record Results on Buried Cultural Properties (매장문화재 자료에 대한 3D 디지털 기록 결과 비교연구)

  • KIM, Soohyun;LEE, Seungyeon;LEE, Jeongwon;AHN, Hyoungki
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.175-198
    • /
    • 2022
  • With the development of technology, the methods of digitally converting various forms of analog information have become common. As a result, the concept of recording, building, and reproducing data in a virtual space, such as digital heritage and digital reconstruction, has been actively used in the preservation and research of various cultural heritages. However, there are few existing research results that suggest optimal scanners for small and medium-sized relics. In addition, scanner prices are not cheap for researchers to use, so there are not many related studies. The 3D scanner specifications have a great influence on the quality of the 3D model. In particular, since the state of light reflected on the surface of the object varies depending on the type of light source used in the scanner, using a scanner suitable for the characteristics of the object is the way to increase the efficiency of the work. Therefore, this paper conducted a study on nine small and medium-sized buried cultural properties of various materials, including earthenware and porcelain, by period, to examine the differences in quality of the four types of 3D scanners. As a result of the study, optical scanners and small and medium-sized object scanners were the most suitable digital records of the small and medium-sized relics. Optical scanners are excellent in both mesh and texture but have the disadvantage of being very expensive and not portable. The handheld method had the advantage of excellent portability and speed. When considering the results compared to the price, the small and medium-sized object scanner was the best. It was the photo room measurement that was able to obtain the 3D model at the lowest cost. 3D scanning technology can be largely used to produce digital drawings of relics, restore and duplicate cultural properties, and build databases. This study is meaningful in that it contributed to the use of scanners most suitable for buried cultural properties by material and period for the active use of 3D scanning technology in cultural heritage.

Flow Resistance and Modeling Rule of Fishing Nets -1. Analysis of Flow Resistance and Its Examination by Data on Plane Nettings- (그물어구의 유수저항과 근형수칙 -1. 유수저항의 해석 및 평면 그물감의 자료에 의한 검토-)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.183-193
    • /
    • 1995
  • Assuming that fishing nets are porous structures to suck water into their mouth and then filtrate water out of them, the flow resistance N of nets with wall area S under the velicity v was taken by $R=kSv^2$, and the coefficient k was derived as $$k=c\;Re^{-m}(\frac{S_n}{S_m})n(\frac{S_n}{S})$$ where $R_e$ is the Reynolds' number, $S_m$ the area of net mouth, $S_n$ the total area of net projected to the plane perpendicular to the water flow. Then, the propriety of the above equation and the values of c, m and n were investigated by the experimental results on plane nettings carried out hitherto. The value of c and m were fixed respectively by $240(kg\cdot sec^2/m^4)$ and 0.1 when the representative size on $R_e$ was taken by the ratio k of the volume of bars to the area of meshes, i. e., $$\lambda={\frac{\pi\;d^2}{21\;sin\;2\varphi}$$ where d is the diameter of bars, 21 the mesh size, and 2n the angle between two adjacent bars. The value of n was larger than 1.0 as 1.2 because the wakes occurring at the knots and bars increased the resistance by obstructing the filtration of water through the meshes. In case in which the influence of $R_e$ was negligible, the value of $cR_e\;^{-m}$ became a constant distinguished by the regions of the attack angle $ \theta$ of nettings to the water flow, i. e., 100$(kg\cdot sec^2/m^4)\;in\;45^{\circ}<\theta \leq90^{\circ}\;and\;100(S_m/S)^{0.6}\;(kg\cdot sec^2/m^4)\;in\;0^{\circ}<\theta \leq45^{\circ}$. Thus, the coefficient $k(kg\cdot sec^2/m^4)$ of plane nettings could be obtained by utilizing the above values with $S_m\;and\;S_n$ given respectively by $$S_m=S\;sin\theta$$ and $$S_n=\frac{d}{I}\;\cdot\;\frac{\sqrt{1-cos^2\varphi cos^2\theta}} {sin\varphi\;cos\varphi} \cdot S$$ But, on the occasion of $\theta=0^{\circ}$ k was decided by the roughness of netting surface and so expressed as $$k=9(\frac{d}{I\;cos\varphi})^{0.8}$$ In these results, however, the values of c and m were regarded to be not sufficiently exact because they were obtained from insufficient data and the actual nets had no use for k at $\theta=0^{\circ}$. Therefore, the exact expression of $k(kg\cdotsec^2/m^4)$, for actual nets could De made in the case of no influence of $R_e$ as follows; $$k=100(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})\;.\;for\;45^{\circ}<\theta \leq90^{\circ}$$, $$k=100(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}\;.\;for\;0^{\circ}<\theta \leq45^{\circ}$$

  • PDF