• 제목/요약/키워드: Surface hydration

검색결과 256건 처리시간 0.021초

콘크리트 슬래브의 소성수축균열 해석모델 (A Numerical Model for Plastic Shrinkage Cracking of Concrete Slab)

  • 곽효경;하수준
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.448-455
    • /
    • 2005
  • In this paper, an analytical model for estimation of the time at which the concrete surface begins to dry is introduced to predict whether or not plastic shrinkage cracks occur. First of all, the validity of a consolidation model for bleeding of cement paste proposed by Tan et al. is verified by comparing the analytical results with the experimental results, and used to evaluate the rate and amount of bleed water of concrete. Also an analytical model for evaporation of bleed water which considers the effect of the temperature variation of concrete surface due to hydration heat on the evaporation rate is proposed, and the experimental and analytical results are then compared to verify the validity of the introduced model. In advance, the time at which the concrete surface begins to dry is estimated using above two analytical models, and compared with the experimental results about the time at which plastic shrinkage cracks occur. From the comparison, it is verified that the proposed model can predict the occurrence of plastic shrinkage cracking with comparative precision.

  • PDF

콘크리트 교면에 적용되는 시트방수재의 접합 인장강도 확인 (Overlap Tensile Strength testing of Waterproofing Sheet used in Concrete Bridges)

  • 안기원;강효진;선윤숙;김천학;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.335-336
    • /
    • 2018
  • This study discusses the development of asphalt based waterproofing sheet applied on the blind side of the concrete substrate. The inorganic coating membrane is applied on top of the waterproofing sheet surface for protection, and adhesive bond to the concrete substrate surface is secured via hydration reaction the cement. The study reveals the experimental results of the overlap section tensile strength to observe the effects of the adhesion strength of this material.

  • PDF

석회석슬래그 시멘트의 강도향상 및 미세분석 : 황산알루미늄의 역할 (Strength improvement and micro analysis of limestone-slag cement : role of aluminum sulfate)

  • 왕의성;왕소용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.161-162
    • /
    • 2023
  • Limestone slag cement is a green and sustainable building material with huge market potential. However, its shortcoming of low early compressive strength needs to be improved. A method of using aluminum sulfate to improve the early strength of ternary mixed mortar was proposed, and its effect and optimal dosage were tested. Macroscopic properties such as mechanical properties and surface electrical resistivity were measured at different dosages (0%, 1%, 2%, 3%). The microstructure and products of the mixtures were tested in detail, including by scanning electron microscopy, thermogravimetric analysis, and X-ray diffraction. The results show aluminum sulfate enhances mechanical properties and significantly increases surface electrical resistivity. The 1% and 2% doses had no adverse effects on the 28-day mechanical properties, while the 3% dose reduced the 28-day strength. Considering the changes in mechanical properties and surface electrical resistivity, 1% aluminum sulfate is the optimal dosage.

  • PDF

Study on durability of densified high-performance lightweight aggregate concrete

  • Wang, H.Y.
    • Computers and Concrete
    • /
    • 제4권6호
    • /
    • pp.499-510
    • /
    • 2007
  • The densified mixture design algorithm (DMDA) was employed to manufacture high-performance lightweight concrete (LWAC) using silt dredged from reservoirs in southern Taiwan. Dredged silt undergoing hydration and high-temperature sintering was made into a lightweight aggregate for concrete mixing. The workability and durability of the resulting concrete were examined. The LWAC made from dredged silt had high flowability, which implies good workability. Additionally, the LWAC also had good compressive strength and anti-corrosion properties, high surface electrical resistivity and ultrasonic pulse velocity as well as low chloride penetration, all of which are indicators of good durability.

Early-age thermal analysis and strain monitoring of massive concrete structures

  • Geng, Yan;Li, Xiongyan;Xue, Suduo;Li, Jinguang;Song, Yanjie
    • Computers and Concrete
    • /
    • 제21권3호
    • /
    • pp.279-289
    • /
    • 2018
  • Hydration heat and thermal induced cracking have always been a fatal problem for massive concrete structures. In order to study a massive reinforced concrete wall of a storage tank for liquefied natural gas (LNG) during its construction, two mock-ups of $0.8m{\times}0.8m{\times}0.8m$ without and with metal corrugated pipes were designed based on the actual wall construction plan. Temperature distribution and strain development of both mock-ups were measured and compared inside and on the surface of them. Meanwhile, time-dependent thermal and mechanical properties of the concrete were tested standardly and introduced into the finite-element (FE) software with a proposed hydration degree model. According to the comparison results, the FE simulation of temperature field agreed well with the measured data. Besides, the maximum temperature rise was slightly higher and the shrinkage was generally larger in the mock-up without pipes, indicating that corrugated pipes could reduce concrete temperature and decrease shrinkage of surrounding concrete. In addition, the cooling rate decreased approximately linearly with the reduction of heat transfer coefficient h, implying that a target cooling curve can be achieved by calculating a desired coefficient h. Moreover, the maximum cooling rate did not necessarily decrease with the extension of demoulding time. It is better to remove the formwork at least after 116 hours after concrete casting, which promises lower risk of thermal cracking of early-age concrete.

개에서 피부세정제 적용빈도가 정상피부에 미치는 영향 (Functional Assessment of Frequency of a Commercial Shampoo for Normal Canine Skin)

  • 유종원;신희주;배슬기;최성원;오태호
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.283-287
    • /
    • 2013
  • Canine skin is a highly dynamic organ that is constantly adapted to changes in its environment. It provides structural, sensory, immunologic, and physiologic functions and contributes an essential barrier function against potential environmental insults. We assessed the changes of canine skin hydration, pH, and protein contents by noninvasive method according to the frequency of application with canine commercial shampoo. Canine commercial shampoo was applied topically every other day, 5 days, and 8 days on different sites, respectively in 8 dogs. Saline-applied site was as a control. Skin hydration was increased and skin surface pH was decreased significantly in canine commercial shampoo-applied site every other day (p < 0.05). Also, skin protein concentration measured by D-squame$^{(R)}$ tape stripping method was increased significantly in canine commercial shampoo-applied site every other day (p < 0.05). There were alterations on every 5 days and 8 days, but not significantly. These results may be recognized that the frequent use of canine commercial shampoo cause abnormalities of the skin barrier function and alteration of stratum corneum integrity/cohesion. Consequently it was suggested that bathing the dog with canine commercial shampoo was appropriate every 5 or 8 days.

조리용수로써 자화수의 기능성에 관한 연구 -건조물의 수화능력을 중심으로- (A study on Availability of Magnetic treatment water as a cooking water)

  • 장정옥;이영미
    • 한국식생활문화학회지
    • /
    • 제11권1호
    • /
    • pp.37-42
    • /
    • 1996
  • 자화수의 조리용수로써 기능에 대하여 연구한 결과 다음과 같은 현상을 관찰하였다. 1. 자화수의 pH의 변화는 수도수, 생수 공히 자화수가 약간 알칼리성을 띄었으며 시간이 지남에 따라 수도수에서는 pH가 유의하게 감소하고 생수에서는 증가하였다. 2. 건조식품을 불림에 있어 자화수의 경우 수도수를 사용한 경우보다 수화율이 유의적으로 높게 나타났다. 자화수에 침수한 버섯의 경우 초기부터 수분 흡수율이 약간 높았으며 90분 이후부터는 유의적으로 높아졌다. 콩은 하루밤 방치후 자화수에 침수한 시료에서 유의적으로 흡수율이 높게 나타났다. 3. 표면장력의 변화는 자화수의 표면장력이 수도수에 비해 작았고 시간의 경과에 따라서 유의하게 감소하였다. 4. 염장식품을 수침한 경우 자화수에서 특히 초기침수 5분 이내에 염장물로부터의 염분 유출량이 유의적으로 많았다.

  • PDF

부상식 매스콘크리트 기초의 수화열 관리 및 온도균열 제어 (Heat of Hydration and Thermal Crack Control for Floating Concrete Mass Foundation)

  • 이인규;김광돈;김태욱;이준석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.156-164
    • /
    • 2010
  • 부상식 면진기초 매스콘크리트의 시공이 6차에 걸쳐 분리타설로 이루어졌다. 선행 Mock-up실험을 통하여 각각 온도이력계측과 수화열해석이 병행되었고 최선의 양생조건과 시공순서가 부여되었다. 그 결과 수화발열과 냉각시 발생가능한 온도균열은 나타나지 않았다. 그러나 현행 콘크리트 시방서 매스콘크리트편의 온도균열지수의 간이식, 정밀식 모두 낮은 범위의 지수를 나타내었다. 이는 수화열 거동 및 균열예측에 있어 온도균열 발생확률이 높은 것으로 나타나, 실제 타설경과 내용과 상이함을 알 수 있었다. 각 시공단계의 계측 및 해석결과는 대상 부재의 크기와 형상을 고려하여 부재내부를 등온도분포영역과 상대적으로 온도경사가 높은 영역으로 분리할 필요가 있음을 추정케 하였다. 결론적으로, 구조형태별 수화발열/냉각시 온도변화에 보다 민감한 특성두께를 정의하여, 현실적인 온도균열지수를 계산하는 과정과 방법이 필요하다고 사료된다.

CA2 혼입 페이스트의 부식저항성에 관한 연구 (A Study on Corrosion Resistance of CA2-Mixed Paste)

  • 김재돈;장일영
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.289-297
    • /
    • 2022
  • Deterioration in durability of structures due to the steel corrosion is difficult to determine whether or not corrosion is initiated and how much propagated, and moreover, repair and maintenance are not easy to deal with. Therefore, preventive treatments can be the best option to avoid the deterioration. Various methods for preventing corrosion of steel, such as electrochemical treatments, anti-corrosion agents and steel surface coatings, are being developed, but economic and environmental aspects make it difficult to apply them to in-situ field. Thus, the purpose of this study was to improve corrosion resistance by using CA-based clinker that are relatively simple and expected to be economically profitable Existing CA-based clinkers had problems such as flash setting and low strength development during the initial hydration process, but in order to solve this problem, CA clinker with low initial reactivity were used as binder in this study. The cement paste used in the experiments was replaced with CA2 clinker for 0%, 10%, 20%, and 30% in OPC. And the mixture used in the chloride binding test for the extraction of water-soluble chloride was intermixed with Cl- 0.5%, 1%, 2%, and 3% by weight of binder content. To evaluate characteristic of hydration heat evolution, calorimetry analysis was performed and simultaneously chloride binding capacity and acid neutralization capacity were carried out. The identification of hydration products with curing ages was verified by X-ray diffraction analysis. The free chloride extraction test showed that the chlorine ion holding ability improved in order OC 10 > OC 30 > OC 20 > OC 0 and the pH drop resistance test showed that the resistance capability in pH 12 was OC 0 > OA 10 > OA 20 > OA 30. The XRD analyses showed that AFm phase, which can affect the ability to hold chlorine ions, tended to increase when CA2 was mixed, and that in pH12 the content of calcium hydroxide (Ca(OH)2), which indicates pH-low resistance, decreased as CA2 was mixed