• 제목/요약/키워드: Surface geometry

검색결과 1,285건 처리시간 0.026초

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

Water Gas Shift 반응에서 Pt/CeO2 촉매의 지지체구조에 따른 촉매활성 연구 (Effect of Support Geometry on Catalytic Activity of Pt/CeO2 Nanorods in Water Gas Shift Reaction)

  • 임효빈;권순진;변창기;안희성;구기영;윤왕래;이광복
    • 한국수소및신에너지학회논문집
    • /
    • 제25권6호
    • /
    • pp.577-585
    • /
    • 2014
  • Nanorod and particle shape $CeO_2$ were synthesized via hydrothermal process and precipitation method, respectively, and used as supports of Pt catalyst for water gas shift (WGS) reaction. Three different durations (12, 48, and 96h) for hydrothermal process were applied for the preparation of nanorod type $CeO_2$. 1.0 wt% of Pt was loaded on the prepared supports with incipient wetness method prior to the catalytic activity tests that were carried out at a GHSV of $95,541h^{-1}$, and a temperature range of 200 to $360^{\circ}C$. Varying duration of hydrothermal process led to the difference in physical characteristics of $CeO_2$ nanorods, such as aspect ratio, BET surface area, pore diameter, and pore volume. Consequently, the catalytic activities of Pt/$CeO_2$ nanorods were affected by the physical characteristics of the supports and appeared to be in the order of Pt/$CeO_2$(12) > Pt/$CeO_2$(48) > Pt/$CeO_2$(96). The comparison of the catalytic activities and results of the analysis (XPS, XRD, SEM, BET and TPR) for the supports revealed that the activity of the catalysts depends on chemical states of the Pt and the support materials in the temperature range that is lower than $280^{\circ}C$. However, the activity is rather dependent on the physical characteristic of the supports because the increased gas velocity limits the mass transfer of reactants in micropores of the supports.

시추공 합성탄성파 기록을 통한 지하 불연속 경계면의 파악 (Identification of Subsurface Discontinuities via Analyses of Borehole Synthetic Seismograms)

  • 김지수;이재영;서용석;주현태
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.457-465
    • /
    • 2013
  • 지반 조사를 위해 흔히 수집하는 지표탐사 자료, 시추조사 자료, 지질공학 자료들을 서로 상관시켜 불연속 경계면 및 암반 파쇄대등의 분포를 파악하였다. 전기비저항 입체도와 공내 영상촬영을 통해 개략적인 지질 연약대의 주향 방향을 분석하고, 시추공 사이 탄성파 토모그래피 속도와 로즈 다이어그램을 통해 지층 및 암반 파쇄대의 공간적인 분포대를 파악하였다. 암반의 동적 물성을 파악하기 위해 S-PS 검층과 ${\gamma}-{\gamma}$ 검층으로 동적 탄성계수를 계산하여 푸아송 비 및 P파 속도와의 상관관계를 알아보았다. 지층의 불연속 경계면은 타격수 N값, 개별적인 밀도나 속도 정보를 이용하여 결정하는 것 보다 물리검층에서 수집한 속도와 밀도로부터 계산한 음향 임피던스의 대비, 즉 반사계수 자료와 시각적으로 잘 상관되었다. 암반에 발달한 주요 파쇄대 구간은 그 상부 경계면이 반사계수와 최적 리커 요소파의 곱말기로 계산된 합성탄성파 트레이스에서 극성이 음인 높은 진폭과 잘 상관되었다. 합성탄성파 기록으로 해석된 주된 파쇄대는 실제로 시추 코어 자료에서 관찰된 코어손실 구간 및 공내 영상촬영 자료에서 평가된 낮은 암질 구간과 잘 부합되었다.

DESIGN OF AIR SEAT CUSHION ORTHOSIS FOR PLEGIA

  • Hong, Jung-Hwa;Kim, Gyoo-Suk;Kim, Jong-Kwon;Mun, Mu-Seong;Ryu, Jei-Cheong;Lee, In-Huk;Lee, Jong-Keun
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.121-123
    • /
    • 2002
  • The design of an air seat cushion for preventing decubitus ulcer includes many design factors such as the even distribution of interface pressure, the minimization of mean and peak interface pressure values, and the reduction of interface shear force and pressure gradient. It involves the anatomic condition of plegia's buttock as well as air pressure in air cells of cushion. As a result, a suitable design of the cushion satisfying the all requirements is a difficult problem. Therefore, an appropriate and effective numerical tool to develop an air cushion orthosis is required. The purpose of the present study was to develop an air seat cushion orthosis having optimized air cells for evenly distributed interface pressure between the buttock and cushion surface. For the purpose, an advanced finite element (FE) model for the design of air cushion was developed. Since the interface pressure and shear force behavior, as well as stress analyses were primary concern, a FE air cell model was developed and verified by the experiments. Then, the interactions of two cells were checked. Also, the human part of the developed numerical model includes every material property and geometry related to buttock and femoral parts. For construction of dimension data of buttock and femoral parts, CT scans were performed. A commercial FE program was employed for the simulation representing the seating process on the orthosis. Then, sensitive analyses were performed with varying design parameters. A set of optimal design parameters was found satisfying the design criteria of the orthosis. The results were utilized to produce a prototype of the orthosis. Experimentally, the buttock interface pressure distributions from the optimized and previous ones were compared. The new seat orthosis showed a significantly improved interface pressure characteristics compared to the most popular one in the market. The new orthosis will be used for the development of the AI(artificial intelligent) controlled seat orthosis fur prevention of decubitus ulcer fur various plegic patients and the elderly.

  • PDF

일사 수광량 보정에 의한 산악지대 매시기온의 공간내삽 (Spatial Interpolation of Hourly Air Temperature over Sloping Surfaces Based on a Solar Irradiance Correction)

  • 정유란;윤진일
    • 한국농림기상학회지
    • /
    • 제4권2호
    • /
    • pp.95-102
    • /
    • 2002
  • 관측밀도가 낮고 지형이 복잡한 산악지역을 대상으로 낮 시간대 기온의 경시변화를 기존의 방법으로 내삽할 경우 일사수광량의 불균일한 분포 때문에 심각한 추정오차가 발생할 수 있다. 이를 해결하기 위해 기존의 기온감율을 고려한 거리역산가중 내삽모형에 일사수광량 보정항을 추가하고 오차경감 정도를 평가하였다. 강원도 평창군 일대 14km$\times$22km 지역을 10m 해상도의 수치고도모형으로 표현하고, 각 격자점에 대해 태양과 지표면 사이의 기하학적 관계를 바탕으로 시간대별 실제 일사 수광량을 직달, 산란, 반사 등 성분별로 계산하였다. 수평면 일사량과의 편차를 산출한 다음 이 지역에서 경험적으로 얻은 일사-기온 변환당량을 적용하여 보정값을 얻었다. 기존의 방법에 의해 내삽된 기온값에 이 보정값을 적용하여 대상지역 전역의 기온분포도를 작성하였다. 대상 지역 내 경사향이 서로 다른 8개 지점에서 기온을 측정하여 기온분포도와 비교한 결과 추정오차가 크게 줄어들었음을 확인할 수 있었다.

도심지역 DSM을 이용한 고해상도 InSAR 위상 시뮬레이션 (High Resolution InSAR Phase Simulation using DSM in Urban Areas)

  • 윤근원;김상완;이용웅;이동천;원중선
    • 대한원격탐사학회지
    • /
    • 제27권2호
    • /
    • pp.181-190
    • /
    • 2011
  • 현재 공간해상도 약 1 m 의 고해상도 X-band SAR 위성인 독일의 TerraSAR-X와 TanDEM-X, 이탈리아의 COSMO-SkyMed가 성공적으로 발사되어 운용되고 있으며 분석 결과 우수한 성능을 보이고 있다. 국내에서도 최고 공간해상도 약 1 m 의 X-band SAR 위성인 KOMPSAT-5가 향후 발사될 예정이다. 이러한 고해상도 SAR 영상 활용이 가능해짐에 따라 SAR Interferometry(InSAR) 기술을 이용한 도심지역 모니터링이 더욱 관심을 받고 있다. 하지만 기존의 InSAR 위상 시뮬레이션 알고리즘은 도심지역에 분포하는 빌딩과 같은 인공구조물 객체에 의해 나타나는 layover 현상과 빌딩 벽면에서 산란되는 신호를 충분히 고려하지 못한다. 본 연구에서는 기존 알고리즘의 한계점을 극복하기 위하여 LIDAR DSM을 이용한 정밀 InSAR 위상과 SAR 반사강도 영상 시뮬레이션 알고리즘을 개발하였다. 대전 지역에서 획득된 TerraSAR-X spotlight 영상과 비교 분석을 통해 개발된 알고리즘의 타당성 분석을 수행하였다. 시뮬레이션 결과로 생성된 InSAR 위상과 SAR 반사강도 영상은 실제 TerraSAR-X spotlight SAR 자료로부터 생성된 결과와 매우 유사하였다. 이러한 결과는 향후 고해상도 SAR 영상을 이용한 도심지역 변화 및 변위탐지 모니터링 연구에 활용될 것이다.

자기공명영상 화질 평가용 팬텀 개발에 관한 연구 (Development of MRI Phantom for Assessing MR Image Quality)

  • 안창범;나동규;김광기;김동성;김인수;이정휘;홍석주;변재호;강현수;장기원;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.89-97
    • /
    • 2006
  • 목적 : 자기공명영상 화질을 평가하는 팬텀으로서 코일 장착도구가 내장된 새로운 형태의 팬텀을 개발하였다. 대상 및 방법 : 자기공명영상 화질평가항목인 절편 두께 정확도, 공간 분해능, 대조도 분해능, 기하학적 정확도, 절편 위치 정확도, 영상강도 균일성, 고스트 신호 백분율, 신호대잡음비 등 총 8개의 사양을 가진 팬텀을 고안하였다. 팬텀의 코일 장착을 위한 장치가 팬텀 표면에 설치 되었다. 개발된 팬텀의 임상적용가능성을 알아보기 위하여 6개의 다른 종류의 자기공명영상기기를 사용하여 영상을 습득하였고 이들 화질이 평가되었다. 결과 : 사용된 모든 자기공명영상기기에서 영상평가에 문제가 없는 영상을 보여주었고 그들의 평가결과는 일부 평가항목에서 실측치와 비교하여 적절한 값 범위에 있음을 확인하였다. 코일장착도구를 사용하여 팬텀을 두부용 코일 안에 설치하는 데 문제가 없음을 확인하였다. 결론 : 본 논문에서 개발된 팬텀은 자기공명영상 화질을 평가하는 데 있어 그 임상적용 가능성이 있음을 보여주었다.

  • PDF

지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰 (A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository)

  • 김영민;권오상;윤찬훈;권상기;김진
    • 방사성폐기물학회지
    • /
    • 제5권1호
    • /
    • pp.65-78
    • /
    • 2007
  • 지하 동굴식 처분장의 건설, 운영 및 중-저준위 방사성폐기물을 처분한 이후 발생하게 되는 오염물질(Rn, CH CO, HS, Radiolysis에 의한 방사능 가스 등)은 적절한 공기량을 필요로 한 곳에 정확히 분배시킬 수 있는 환기시스템에 의해 통제되도록 하여야한다. 특히 지하 처분장은 여러 개의 진입 터널, 저장 터널, 공기 유입-배기 터널, 수직갱 등으로 이루어진 복잡한 회로망의 형태로 나타나기 때문에 이에 적절한 기술적 접근이 필요하다. 본 논문에서는 이러한 환기시스템 구축을 위한 기술적 접근을 위해 미국의 WIPP (Waste Isolation Pilot Plant)처분장과 스웨덴의 SFR (Slutforvar for Reaktoravfall) 중-저준위 처분장을 모델로 하여 두 처분장의 소요환기량을 선정하고 설계상 통풍로의 단면적, 길이, 표면 거칠기 등을 고려한 환기회로를 구성하였으며, 수학적으로 계산되는 각 회로의 저항에 대해 기술하였다. 또한 이를 바탕으로 적절한 선풍기의 용량과 수직갱 운용방안을 설계하였다. 두 처분장의 지형상의 규모 및 환기시설 비교 결과, SFR 처분장에 비해 WIPP 처분장에서와 같이 병렬구조가 많을수록 처분장 전체의 저항이 감소되며 이러한 결과로 환기시스템의 운용비 절감효과를 얻을 수 있다는 결론을 얻었다. 따라서 처분용량 증대를 위한 대단면의 SFR 처분장 구조와 전체 저항 감소를 위한 WIPP 처분장의 병렬구조를 조합한 형태가 가장 합리적이며 효율적인 환기가 이루어질 수 있을 것으로 사료된다.

  • PDF

Doublet 센서배열의 수중음원 위치 추정 성능 향상을 위한 시간지연 추정 기법 (Time-delay Estimation Method for Performance Enhancement of Underwater Source Localization using Doublet Array)

  • 심민섭;이지혁;이형신
    • 한국산학기술학회논문지
    • /
    • 제21권5호
    • /
    • pp.69-76
    • /
    • 2020
  • 수중에서 방사된 음원의 신호는 해수면, 해저면 반사에 의한 다중경로 시간지연(multi-path time-delay)을 포함하여 체계(system)의 센서에 수신된다. 다중경로 환경과 복잡한 해양환경의 외란(disturbance)에 의해 수신된 신호간 상관성(coherence)이 저하된다. 따라서, 신호간 시간지연값을 이용하여 수중음원의 위치를 추정하는 체계는 추정성능의 저하가 나타난다. 이러한 환경에서도 강인한 음원 위치 추정성능을 위해 선배열(uniform line array), 평면배열(rectangular array)과 같은 다양한 형태의 센서배열과 빔형성(beamforming) 기법, 비용함수(cost-function)과 같은 신호처리를 이용하여 왔다. 본 연구에서는 선배열 형태의 doublet array와 추정된 시간지연값 보정 기법을 이용하고자 한다. 3 개의 doublet array를 동일 선에 위치하였으며 각각의 doublet array에 수신된 신호간의 시간지연값을 2 단계로 추정하였다. 수신신호에 대해 상호상관(cross-correlation) 함수를 적용하여 추정된 시간지연값을 수신신호의 중심주파수(center-frequency)와 array의 개구경(aperture) 및 수중음원과의 기하학적 관계에 따라 보정하여 최종의 시간 지연값을 얻었으며 이로부터 음원의 거리와 방위를 추정하였다. 제안한 기법의 타당성을 확인하기 위해, Monte-Carlo method를 이용하여 시뮬레이션하였다.

배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가 (Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste)

  • 김계홍;오원진;이근우;서범경
    • 방사성폐기물학회지
    • /
    • 제3권3호
    • /
    • pp.159-165
    • /
    • 2005
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관류를 재활용하거나 처분하기 위해서는 배관 내부의 정확한 방사선학적인 오염 특성의 평가가 선행되어야 한다. 그러나 기존의 측정법인 survey-meter를 이용한 오염도의 직접 측정은 배관 내부와 같은 국소지역의 오염 특성을 정확하게 평가할 수 없으며, 간접법을 이용한 표면오염도 측정의 경우도 시료채취의 어려움뿐만 아니라 시료채취 시 작업자의 오염 가능성이 있기 때문에 적용성에 많은 문제점이 있다. 본 연구에서는 Monte Carlo 모사기법을 이용해 직경이 작은 배관 내부의 베타선 오염도를 측정하기 위하여 플라스틱 섬광체를 모사하였으며, 모사 결과에서 베타선 에너지를 효율적으로 측정할 수 있는 최적의 플라스틱 섬광체 두께 및 형상을 도출할 수 있었다. 이 전사모사 결과를 바탕으로 섬광체의 가공 및 배관 내부에서의 검출기 이송 문제를 고려해 검출기를 제작하였으며 그 특성을 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 검출기 성능을 확인하였고, 파이프 내부처럼 국소 지역의 방사선학적 오염 특성 평가를 위한 검출기 개발 가능성을 확인하였다.

  • PDF