• Title/Summary/Keyword: Surface fire

Search Result 659, Processing Time 0.036 seconds

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

Fireproof Performance Study of ICT Fire Damper by Using Experimentalmethode (실험적 방법에 의한 ICT 파이어 댐퍼의 내화성능연구)

  • Hur, Nam-Soo;Kim, In-Whan;Jang, Sung Cheol;Kim, Jae-Woong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.82-89
    • /
    • 2014
  • In this paper, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.

A Fundamental Study on the Performance of Spalling Resistance of High Performance Concrete with Material of Lateral Confinement Subjected to Fire (화재시 횡구속재 변화에 따른 고성능 콘크리트의 폭열방지성능에 관한 기초적 연구)

  • 배정렬;황인성;홍상희;한민철;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.47-50
    • /
    • 2002
  • This paper presents the results of fire resistance properties of high performance concrete varying with fiber kinds and the size of metal lath in order to verify the validities of fiber on the spatting resistance by fire. Metal lath, glass fiber and carbon fiber are used to confine the concrete. According to test results, plain concrete without lateral confinement and confined concrete with glass fiber and carbon fiber show entire failure after exposed to fire, while confined concrete with metal lath take place in the form of slight surface spatting by fire, which has favorable spatting resistance of concrete. As for the effect of the size of metal lath, when the size of metal lath is more than 1.2mm of thickness, the residual strength of concrete exposed to fire maintains more than 80% of its original strength. However, glass fiber and carbon fiber does not perform desirable spatting resistance by fire due to loss of lateral confinement of fiber exposed to fire caused by melting of fiber and reducing bond strength between concrete and fiber.

  • PDF

Non destructive test of Fire-damaged reinforced concrete columns with high strength concrete (화재 피해를 입은 고강도 철근 콘크리트 압축부재의 비파괴 검사)

  • Seo Ji Min;Lee Su Jin;Choi Eun Gyu;Shin Yeong Soo;Lee Cha Don;Kwon Young Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.13-16
    • /
    • 2005
  • This study is aimed to investigate the strength variation of fire-damaged reinforced concrete column by non-destructive test. It is studied to infer the recovery degree of residual strength of fire-damaged concrete. For measuring the surface hardness of RC columns. Schmidt hammer test is used. Testing is performed three-times: before fire test, directly after fire test and after 20 days.

  • PDF

Study for Binary Liquid Type Fire Retardant White Paint of Polyurethane Lacquer (저연기성 이액형 방염우레탄락카 백색도료 연구)

  • Kwon, Kyungok
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.527-530
    • /
    • 2007
  • The binary liquid type fire retardant paint of polyurethane (alkyd resin) lacquer is developed to cover the defect of one liquid type white paint of chlorinated rubber used generally but which has weak surface and poor adhesive strength to the wood as well as generating much black smoke when it is firing. The properties of the composition of binary liquid type of white paint of polyurethane lacquer developed in this study for using to wood has shown that the better suppressed smoke generation and enhanced the adhesive strength to the wood than that of fire retardant white paint used.

Development of Inorganic Fire Protection Materials for High Strength Concrete (구조체 보호를 위한 고내화성 마감재 적용에 관한 실험적 연구)

  • Jung, Suk-Jo;Song, Hun;Kwon, Choon-Woo;Kim, Young-Yup;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.885-888
    • /
    • 2006
  • Nowaday, High strength concrete(HSC) has been mainly used in high rise building. HSC have superior property as well as improvement in durability compared with ordinary strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. Thus, this study is concerned with experimentally investigation fire resistance of the inorganic fire protection materials at high temperatures up to $800^{\circ}C$. From the test result, developed inorganic binder becomes general that with rising temperature the compressive strength of the material increases in tendency. Therefore, the results indicate that it is possible to fireproof panels, fire protection of materials, etc.

  • PDF

Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation (비닐절연전선의 산화물 성장 특성과 화재조사에의 적용)

  • Kim, Hyang-Kon;Choi, Chung-Seog;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.

Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks (석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구)

  • Kim, Hong;Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

Literature Review and Current Trends of Automated Design for Fire Protection Facilities (화재방호 설비 설계 자동화를 위한 선행연구 및 기술 분석)

  • Hong, Sung-Hyup;Choi, Doo Chan;Lee, Kwang Ho
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.99-104
    • /
    • 2020
  • This paper presents the recent research developments identified through a review of literature on the application of artificial intelligence in developing automated designs of fire protection facilities. The literature review covered research related to image recognition and applicable neural networks. Firstly, it was found that convolutional neural network (CNN) may be applied to the development of automating the design of fire protection facilities. It requires a high level of object detection accuracy necessitating the classification of each object making up the image. Secondly, to ensure accurate object detection and building information, the data need to be pulled from architectural drawings. Thirdly, by applying image recognition and classification, this can be done by extracting wall and surface information using dimension lines and pixels. All combined, the current review of literature strongly indicates that it is possible to develop automated designs for fire protection utilizing artificial intelligence.

Extinguishing Charactristics of Water Mist by Discharge Properties (방사특성 변화에 따른 미세물분무의 소화특성)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.41-48
    • /
    • 2001
  • Halogen-based fire suppressing agents have been the most effective fire suppressants and widely used for flammable liquid and electric fire. However they have environmental problems causing stratospheric ozone depletion and globe warming. As a substitution of halon, fire suppression system using fine water mist is one of an effective fire suppressant. Suffocating and cooling effects of water mist are increased by the evaporation characteristics because it has droplet size less than 1,000 $\mu{m}$ and very large surface area. In this study, the extinguishing characteristics of fire was measured with changing of water mist droplet size, flow density; discharge pressure, and fire size. As a result, the extinguishing time of pool fire was shortened with the increase of flow density and in case of low flow density less than 0.5$\pm$0.05 ml/$\textrm{cm}^2$ . min, the extinguishing time was shortened with the increase of droplet size. The cycling discharge was effective for $\eta$-heptane pool fire, and total amount of water mist required to extinguish fire was reduced to a quarter compare with continuous discharge.

  • PDF