• Title/Summary/Keyword: Surface etching effect

Search Result 394, Processing Time 0.031 seconds

THE EFFECT OF ADDITIONAL ENAMEL ETCHING ON MICROLEAKAGE OF THE ADHESION OF SELF-ETCHING PRIMER SYSTEM (자가 산부식 프라이머 시스템 사용시 인산에 의한 부가적인 산부식이 미세누출에 미치는 영향)

  • Yoon, Jung-Jin;Min, Kyung-San;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.363-368
    • /
    • 2003
  • The purpose of this study is to evaluate the effect of additional enamel etching with phosphoric acid on the microleakage of the adhesion of self-etching primer system. Class V cavity($4mm{\times}3mm{\times}1.5mm$) preparations with all margins in enamel were prepared on buccal surface of 42 extracted human upper central incisor teeth. Prepared teeth were randomly divided into 3 groups. Group 1:no additional pretreatment with 37% phosphoric acid (NE). Group 2:additional pretreatment with 37% phosphoric acid for 10 seconds (E10s). Group 3:additional pretreatment with 37% phosphoric acid for 20 seconds (E20s). The adhesives(Clearfil SE $Bond^{\circledR}$, Kuraray, Osaka, Japan) and composite resins(Clearfil $AP-X^{\circledR}$, Osaka, Kuraray, Japan) were applied following the manufacturer's instructions. All the specimens were finished with the polishing disc(3M dental product, St Paul, MN, USA), thermocycled for 500 cycles between $5^{\circ}C$ and $55^{\circ}C$ and resected apical 3-mm root. 0.028 stainless steel wire was inserted apically into the pulp chamber of each tooth and sealed into position with sticky wax. Surrounding tooth surface was covered with a nail varnish 2 times except areas 1mm far from all the margins. After drying for one day, soaked the samples in the distilled water. Microleakage was assessed by electrochemical method(System 6514, $Electrometer^{\circledR}$), Keithley, USA) in the distilled water. In this study, the microleakage was the lowest in group 1 (NE) and the highest in group 3(E20s)(NE

Tooth surface treatment strategies for adhesive cementation

  • Rohr, Nadja;Fischer, Jens
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.85-92
    • /
    • 2017
  • PURPOSE. The aim of this study was to evaluate the effect of tooth surface pre-treatment steps on shear bond strength, which is essential for understanding the adhesive cementation process. MATERIALS AND METHODS. Shear bond strengths of different cements with various tooth surface treatments (none, etching, priming, or etching and priming) on enamel and dentin of human teeth were measured using the Swiss shear test design. Three adhesives (Permaflo DC, Panavia F 2.0, and Panavia V5) and one self-adhesive cement (Panavia SA plus) were included in this study. The interface of the cement and the tooth surface with the different pre-treatments was analyzed using SEM. pH values of the cements and primers were measured. RESULTS. The highest bond strength values for all cements were achieved with etching and primer on enamel ($25.6{\pm}5.3-32.3{\pm}10.4MPa$). On dentin, etching and priming produced the highest bond strength values for all cements ($8.6{\pm}2.9-11.7{\pm}3.5MPa$) except for Panavia V5, which achieved significantly higher bond strengths when pre-treated with primer only ($15.3{\pm}4.1MPa$). Shear bond strength values were correlated with the micro-retentive surface topography of enamel and the tag length on dentin except for Panavia V5, which revealed the highest bond strength with primer application only without etching, resulting in short but sturdy tags. CONCLUSION. The highest bond strength can be achieved for Panavia F 2.0, Permaflo DC, and Panavia SA plus when the tooth substrate is previously etched and the respective primer is applied. The new cement Panavia V5 displayed low technique-sensitivity and attained significantly higher adhesion of all tested cements to dentin when only primer was applied.

A SHEAR BOND STRENGTH OF RESIN CEMENTS BONDED TO PRESSABLE PORCELAIN WITH VARIOUS SURFACE TREATMENTS

  • Lee Jong-Yeop;Im Eui-Bin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.379-386
    • /
    • 2003
  • Statement of problem. Resin cements are widely used in adhesive dentistry specially on all ceramic restorations. It is needed to find out adequate bonding strength between different porcelain surface treatments, commercially available porcelains, and different resin cement systems. Purpose. The purpose of this study was to evaluate shear bond strength of resin cements bonded to porcelains in three different modalities; 5 different porcelain surface treatments, 3 different resin cement systems and 3 different commercially available pressable porcelains. Material and Method. This study consisted of 3 parts. Part I examined the effect of five different surface treatments on the pressable porcelain. Fifty discs (5 mm in diameter and 3 mm in height) of Authentic porcelain were randomly divided into 5 groups (n = 10). The specimens were sanded with 320 grit SiC paper followed by 600 grit SiC paper. The specimens were treated as follow: Group 1-Sandblasting (aluminum oxide) only, Group 2 - sandblasting/ silane, Group 3 - sandblasting/ acid etching/ silane, Group 4 - acid etching only, Group 5 - acid etching/ silane. Part II examined the shear bond strength of 3 different resin cement systems (Duolink, Variolink II, Rely X ARC) on acid etching/ silane treated Authentic pressable porcelain. Part 3 examined the shear bond strength of Duolink resin cement on 3 different pressable porcelains (Authentic, Empress I, Finesse). All cemented specimens were stored in distilled water for 2 hours and tested with Ultradent shear bond strength test jig under Universal Instron machine until fracture. An analysis of variance(ANOVA) test was used to evaluate differences in shear bond strength. Result. The shear bond strength test resulted in the following: (1) Acid etched porcelains recorded greater shear bond strength values to the sandblasted porcelains. (2) Silane treated porcelains recorded greater shear bond strength values to non-silane treated porcelains. (3) There was no significant difference between sandblasting/ acid etching/ silane treated and acid etching/ silane treated porcelains. However those values were much higher than other three groups. (4) The shear bond strength with Variolink II was lower than the value of Duolink or Rely X ARC. (5) The shear bond strength of Finesse was lower than the value of Authentic or Empress I.

THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES (Glass ionomer cement 표면의 산부식 효과에 관한 연구)

  • Han, Seung-Weon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF

Effect of Plasma Etching and $PdCl_2/SnCl_2$ Catalyzation on the Performance of Electroless Plated Copper Layer (플라즈마 에칭 및 $PdCl_2/SnCl_2$ 촉매조건이 무전해 동도금 피막의 성능에 미치는 영향)

  • 오경화;김동준;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.7
    • /
    • pp.843-850
    • /
    • 2003
  • Cu/PET film composites were prepared by electroless copper plating method. In order to improve adhesion between electroless plated Cu layer and polyester (PET) film, the effect of pretreatment conditions such as etching method, mixed catalyst composition were investigated. Chemical etching and plasma treatment increased surface roughness in decreasing order of Ar>HCl>O$_2$>NH$_3$. However, adhesion of Cu layer on PET film increased in the following order: $O_2$<Ar<HCl<NH$_3$. It indicated that appropriate surface roughness and introduction of affinitive functional group with Pd were key factors of improving adhesion of Cu layer. PET film was more finely etched by HCI tolution, resulting in an improvement in adhesion between Cu layer and PET film. Plasma treatment with NH$_3$produced nitrogen atoms on PET film, which enhances chemisorption of Pd$^{2+}$ on PET film, resulting in improved adhesion and shielding effectiveness of Cu layer deposited on the Pd catalyzed surface. Surface morphology of Cu plated PET film revealed that Pd/Sn colloidal particles became more evenly distributed in the smaller size by increasing the molar ratio of PdCl$_2$; SnCl$_2$from 1 : 4 to 1 : 16. With increasing the molar ratio of mixed catalyst, adhesion and shielding effectiveness of Cu plated PET film were increased.d.

실리콘 기판위의 증착된 AAO Barrier Layer의 $Cl_2/BCl_3$ Neutral Beam Etching

  • Kim, Chan-Gyu;Min, Gyeong-Seok;O, Jong-Sik;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.135-136
    • /
    • 2011
  • 본 연구에서는 실리콘 기판위의 형성된 AAO (Anodic Aluminum Oxide)의 barrier layer를 $Cl_2/BCl_3$ gas mixture에서 Neutral Beam Etching (NBE)과 Ion Beam Etching (IBE)로 각각 식각한 후 그 결과를 비교하였다. 이온빔의 경우 나노사이즈의 AAO pore의 charging에 의해 pore 아래쪽의 위치한 barrier layer를 어떤 식각조건에서도 제거하지 못하였다. 하지만, charging effect가 없고, 높은 중성화율을 나타내는 low angle forward reflected 방식의 neutral beam etching (NBE)에서는 $BCl_3$-rich $Cl_2/BCl_3$ gas mixture인 식각조건에서 AAO pore에 휘발성 $BO_xCl_y$를 형성하면서 barrier layer를 제거할 수 있었다.

  • PDF

Self-assembly of Fine Particles Applied to the Production of Antireflective Surfaces

  • Kobayashi, Hayato;Moronuki, Nobuyuki;Kaneko, Arata
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • We introduce a new fabrication process for antireflective structured surfaces. A 4-inch silicon wafer was dipped in a suspension of 300-nm-diameter silica particles dispersed in a toluene solution. When the wafer was drawn out of the suspension, a hexagonally packed monolayer structure of particles self-assembled on almost the complete wafer surface. Due to the simple process, this could be applied to micro- and nano-patterning. The self-assembled silica particles worked as a mask for the subsequent reactive ion etching. An array of nanometer-sized pits could be fabricated since the regions that correspond to the small gaps between particles were selectively etched off. As etching progressed, the pits became deeper and combined with neighboring pits due to side-etching to produce an array of cone-like structures. We investigated the effect of etching conditions on antireflection properties, and the optimum shape was a nano-cone with height and spacing of 500 nm and 300 nm, respectively. This nano-structured surface was prepared on a $30\;{\times}\;10-mm$ area. The reflectivity of the surface was reduced 97% for wavelengths in the range 400-700 nm.

A Study on Thin-Film Silicon Solar Cells with Multi-Architecture Etching Technique to Improve Light Trapping (광 포획 향상을 위한 다중 아키텍처 식각 기술을 적용한 박막 실리콘 태양전지에 관한 연구)

  • Hyeong Gi Park;Junsin Yi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.337-344
    • /
    • 2024
  • This work focuses on improving the light-harvesting efficiency of thin-film silicon solar cells through innovative multi-architecture surface modifications. To create a regular optical structure, a lithographic process was performed to form it on a glass substrate through various etching processes, from Etch-1 to Etch-3. AZO was deposited on top of the structures and re-etched to create a multi-architectural surface. These surface-modified structures improved the light absorption and overall performance of the solar cell through changes in optical and physical properties, which we will analyze. In addition, we investigated the effect of post-cleaning on the etched glass structures through EDX analysis to understand the mechanism of the etching action. The results of this study are expected to provide important guidelines for the design and fabrication of solar cells and other photovoltaic devices.

EFFECT ON THE SHEAR BOND STRENGTH OF A COMPOMER TO DENTIN ACCORDING TO SURFACE CONDITIONING (상아질 표면처리방법이 compomer의 전단결합 강도에 미치는 영향에 관한 연구)

  • Kim, Soo-Mee;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.597-606
    • /
    • 1998
  • The purpose of this study was to evaluate the shear bond strength of the Compoglass Carvifil bonded on the dentin surface according to etching or non-etching and two time application or three time application of single component. Human non-carious 60 extracted 3rd molar were used. The occlusal dentin surfaces of all teeth were exposed with Diamond Wheel Saw and polished with Lapping & Polishing machine(South Bay Technology Co., U.S.A). The teeth were then distributed randomly into four groups of 15 teeth each and dentin surface were conditioned as following. Control group : Non-etching, two times application of Syntac Single Component. (According to manufacture's instruction) Experimental group 1 : Non-etching, three times application of Syntac Single Component. Experimental group : 2 Etching, two times application of Syntac Single Component. Experimental group 3 : Etching, three times application of Syntac Single Component. Compoglass were bonded to exposed dentin surfaces and all samples were placed in distilled water for 7 days. The shear bond strengths were measured by universal testing machine (SHIMADAZU AUTOGRAPH, AGS-4D., Japan). The results were as follows : 1. Experimental group 3 revealed the highest value (30.75${\pm}$4.74 MPa) and control group revealed the lowest value(14.85${\pm}$2.69 MPa). There was significant difference of shear bond strength among four groups(P<0.01) 2. The acid-etching groups (experimental group 2, 3) had higher shear bond strengths than non etching groups(control group and experimental group 1). 3. The additional application of Syntac single component groups revealed a higher bond strength than two times application groups (control group and experimental group 2).

  • PDF