• 제목/요약/키워드: Surface electrical stimulation

검색결과 99건 처리시간 0.027초

장쇄지방산 LB박막의 전류-전압 특성에 관한 연구 (A study on the I-V Properties of Long Chain Fatty Acid of LB Thin Films)

  • 전동규;장헌;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.913-919
    • /
    • 2000
  • We give pressure stimulation into long chain fatty acid of LB thin films then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 13, 17 and 19. The I-V characteristic of the device is measured from 0[V] to +1.5[V]. We have investigated the capacitance because this fatty acid system have a accumulated layers. The maximum value of measured current is increased as the number of accumulated layers are decreased. The capacitor properties of a thin film is better as the distance between electrodes is smaller. The results have shown the insulating materials and could control the conductivity by accumulated layers.

  • PDF

LB박막의 전자이동 특성에 관한 연구 (A Study on the Electronic Properties of LB Thin Films)

  • 송진원;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Abstract We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

Fabrication, Optoelectronic and Photocatalytic Properties of Some Composite Oxide Nanostructures

  • Zou, C.W.;Gao, W.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 2010
  • This is an overview paper reporting our most recent work on processing and microstructure of nano-structured oxides and their photoluminescence and photo-catalysis properties. Zinc oxide and related transition metal oxides such as vanadium pentoxide and titanium dioxide were produced by a combination of magnetron sputtering, hydrothermal growth and atmosphere controlled heat treatment. Special morphology and microstructure were created including nanorods arrays, core-brushes, nano-lollipops and multilayers with very large surface area. These structures showed special properties such as much enhanced photoluminescence and chemical reactivity. The photo-catalytic properties have also been promoted significantly. It is believed that two factors contributed to the high reactivity: the large surface area and the interaction between different oxides. The transition metal oxides with different band gaps have much enhanced photoluminescence under laser stimulation. Use of these complex oxide structures as electrodes can also improve the energy conversion efficiency of solar cells. The mixed oxide complex may provide a promising way to high-efficiency photo emitting materials and photo-catalysts.

와우 갑각 전기자극 뇌간유발반응용 원추형 전극의 개발 (Development of Cone-Shaped Electrode for Promontory Stimulation Electrically Auditory Brainstem Response)

  • 허승덕;정동근;강명구;김리석;고도흥
    • 음성과학
    • /
    • 제10권4호
    • /
    • pp.181-187
    • /
    • 2003
  • This paper introduces a new zinc coated copper wire electrode with coiled cone shape which has low surface resistance and tolerance to the motion artifact for promontory stimulation electrically auditory brainstem responses (PSEABR). Auditory brainstem responses (ABR) can be used to predict hearing threshold level with a great deal of accuracy particularly for a young child who cannot cooperate mechanically and some hearing impaired who are exaggerating a hearing loss for economic compensation. While severe profound sensorineural hearing losses may not be implemented by auditory potentials, PSEABR is proven as a useful tool even for some sensorineural related hearing impaired. It was shown that PSEABR gives the electrical stimuli to promontory of the cochlear instead of giving acoustic stimuli. For this reason, PSEABR can be used as an alternative for cochlear implantation, and can also be used as an optimal device selection and neural information for MAP. It was found that the role of electrode is very important in PSEABR. Even though this cone-shaped electrode was applied in animal experiments, waveforms are well produced by PSEABR. Thus, it was concluded that cone-shaped electrode turned out to be a useful preoperative audiological evaluation tool in deciding time for cochlear implantation surgery.

  • PDF

무릎 통증이 있는 엘리트 배드민턴 선수를 위한 건식 E-textile 전극의 EMS(Electirc muscle stimulation) 보호대 설계 및 효과 (A Study on EMS Protective Gear Design and Its Effects for Elite Badminton Players with Knee Pain)

  • 이주일;박진희;김주용
    • 패션비즈니스
    • /
    • 제27권5호
    • /
    • pp.93-107
    • /
    • 2023
  • This study aimed to design a knee brace with dry electrode EMS (Electrical Muscle Stimulation) for elite badminton players suffering from knee pain and assess its effectiveness in relieving pain and improving mobility. The assessment measured knee joint range of motion (ROM), Sargent jump height, and pain perception using a visual analog scale (VAS). Four experimental groups were established: stability, pain induction after 100 squats, muscle soreness induction with a regular knee brace, and muscle soreness induction with the EMS knee brace. The most suitable knee brace was selected from four samples to design the EMS knee brace. The conductive fabric was integrated into the inner surface of the knee brace to enhance EMS conductivity for the quadriceps muscles. Tensile strength tests showed that the dry electrode did not significantly affect the physical functionality of the knee brace.Regarding knee joint ROM and Sargent jump height, the EMS knee brace outperformed muscle soreness induction with a regular knee brace and wearing a standard knee brace. VAS measurements demonstrated that the EMS braces effectively alleviated pain perception in most cases. The results indicate the potential for developing EMS braces to alleviate pain and prevent injuries for athletes across various sports.

냉(cold)적용 방법에 따른 동통 역치 및 피부 온도의 변화 (The Changes in the Electrical Stimulation Induced Pain Threshold and Skin Temperatures According to Methods of Cold Application)

  • 김선엽;류이화;박은화;배혜진
    • 대한물리치료과학회지
    • /
    • 제3권3호
    • /
    • pp.25-34
    • /
    • 1996
  • The purpose of this experimental study was conducted to examine the most effective modality between two methods of cold application(ice pack and cold spray), the most effective length of time for the application and the continuing effect after each type of cold application. Sixty students were assigned randomly to each of two cold application methods; (a) ice pack, (2) cold spray. Each methods was applied to the posterior surface of right forearm with subject in the sitting position. Skin temperature and the electrical stimulation induced pain threshold were measured before each application and every five degree ($^{\circ}C$) decline point after ice pack application. They were also measured point of minimum skin temperature after cold spray application. The results of this study are as follows; 1. Skin temperatures according to the cold spray application decreased to a range of $4.2^{\circ}C{\sim}9.2^{\circ}C$(male, p<0.001), $3.6^{\circ}C{\sim}7.6^{\circ}C$(female, p<0.001). 2. Pain threshold according to the cold spray application increased to a range of $0.6mA{\sim}1.9mA$(male, p<0.01), $1.2mA{\sim}3.86mA$(female, p>0.05).

  • PDF

고빈도 경피신경전기자극이 편마비 환자의 하지 경직과 균형에 미치는 즉각적 효과 (Immediate effects of High-Frequency Transcutaneous Electrical Nerve Stimulation on the Lower Limb Spasticity and the Balance in the Stroke Patient)

  • 조휘영;인태성;이순현;이규창;신원섭;이용우;송창호
    • 대한물리의학회지
    • /
    • 제5권3호
    • /
    • pp.487-498
    • /
    • 2010
  • Purpose : To investigate the immediate effects of transcutaneous electrical nerve stimulation(TENS) on the spasticity and the balance in the stroke patients. Methods : 26 subjects with spasticity over lower limbs were allocated randomly into two groups : (1) TENS group, (2) placebo-TENS group. TENS was applied on the both gastrocnemius for 60 minutes(100 Hz, 0.25 ms, 2 times sensory threshold). The modified Ashworth Scale(MAS) and Manual Muscle Tester were used to assess the spasticity of the ankle plantar flexors. Static balance under three conditions was measured by force-plate; in (1) the condition of standing with eyes opened, (2) with eyes closed and (3) the condition of standing on unstable surface with eyes opened. Results : When compared with the pre and post TENS application, TENS showed significant reduction of ankle spasticity in MAS and MMT measurement. Also, Application of high-frequency TENS improved the balance under three conditions. Conclusion : A single session of TENS to stroke patients could reduce spasticity and improve the balance.

Effects of Ankle Control Training Using Neuromuscular Electrical Stimulation on Leg Muscle Activation and Balance in Patients with Stroke

  • Soo-Yong Lee;Hyo-Jung Park;Yu-Sik Choi
    • The Journal of Korean Physical Therapy
    • /
    • 제35권5호
    • /
    • pp.145-150
    • /
    • 2023
  • Purpose: This study examined the effects of ankle control training using neuromuscular electrical stimulation (NMES), leg muscle activation, and balance in stroke patients. Methods: Thirty-one stroke patients diagnosed with cerebral infarction and cerebral hemorrhage were selected for the study. The experimental group underwent ankle control training using NMES, while the control group applied NMES to the paretic tibialis anterior muscle for 30 minutes per session, five times a week for four weeks. The muscle activity changes were measured using surface electromyography, and balance parameters were evaluated using a functional reach test (FRT). Results: The intra-group comparison of the concentric muscle activity revealed improvements in the experimental group, including paretic tibialis anterior (TA) muscle (p<0.05), medial gastrocnemius muscle (MG) (p<0.01), and lateral gastrocnemius muscle (LG) (p<0.05), as well as MG (p<0.05), LG (p<0.05), soleus muscle (p<0.05) of the non-paretic side, and soleus muscle symmetry index (p<0.05). The intra-group comparison of the eccentric muscle activity showed improvements in the experimental group, including MG (p<0.01) and LG (p<0.01) of the paretic side, as well as MG (p<0.01), LG (p<0.01) of the non-paretic side, and LG symmetry index (p<0.01). The intra-group comparison of the functional reach test revealed significant differences in the test results in the experimental and control groups (p<0.05). Conclusion: Ankle control training using NMES had a positive effect on the changes in muscle activation and improved balance in patients with stroke.

정상 망막과 변성 망막을 위한 전기자극 파라미터 (Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina)

  • 진계환;구용숙
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.73-79
    • /
    • 2008
  • 망막색소변성(retinitis pigmentosa: RP)과 연령 관련 황반변성(age-related Macular Degeneration: AMD)은 망막변성으로 인해 실명에 이르는 대표적인 질환이며 망막이식장치의 개발을 통해 치료될 수 있다고 간주되고 있다. 최근에 국내에서도 망막이식장치 개발을 위한 연구팀이 조직되었다. 성공적인 망막이식장치 개발을 위하여 여러 가지 선결요소가 필요하지만 그 중 한 가지가 이식장치에 인가할 전기자극을 최적화하는 것이다. 변성망막의 전기적 특성은 정상 망막과 다르리라 예측되므로 우리는 장차 개발될 망막 이식장치에 인가할 전기자극 최적화를 위한 가이드라인을 제공하기 위해 정상 망막과 변성 망막의 전압자극 파라미터에 관한 실험을 하였다 망막을 분리한 후 망막절편을 신경절세포 층이 다채널전극의 표면을 향하게 하여 전극에 붙인다 in-vitro 상태에서 망막 신경절세포의 전기신호를 기록하기 위해 전극 직경: $30{\mu}m$, 전극간 거리: $200{\mu}s$, 전극 임피던스 1kHz 에서 $50k{\Omega}$인 8행 8열의 다채널전극을 사용하였다. 다채널전극의 60채널 중 두 채널을 자극전극과 접지로 사용하여 단극전기자극을 인가하였고 나머지 전극을 기록전극으로 사용하였다. 가한 전기자극은 전압자극으로 전하균형을 맞춘 이상성자극을 아노딕 사각파를 먼저 주고 캐쏘딕 사각파가 나중에 나오는 형태로 두 사각파간의 지체는 없도록 하였으며 동일한 자극을 2초 간격으로 50회 반복하여 인가하였다. 다양한 전기자극을 사용하였는 바 첫째는 사각파의 크기를 달리하였다 $(0.5{\sim}3V)$. 둘째는 사각파의 시간을 달리하였다 $(100{\sim}1,200{\mu}s)$. 전하밀도는 옴의 법칙과 쿨롱의 법칙을 이용하여 계산하였다. 전기자극으로 유발된 반응은 50회 자극에 대한 평균치를 얻은 후 자극 후 히스토그램(PSTH)을 그려 분석하였다. 전압자극의 크기를 $0.5{\mu}3V$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극은 1.5V이었고 이때 계산된 전하밀도의 역치는 $2.123mC/cm^2$이었다. 전압의 크기를 2V로 고정하고 자극 지속시간을 $100{\sim}1,200{\mu}s$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극의 역치는 $300{\mu}s$에서 관찰되었다. 이때 계산된 전하밀도의 역치는 $1.698mC/cm^2$이었다. L-(1)-2-amino-4-phosphonobutyric acid (APB)을 사용하여 ON-경로를 차단한 후에 전기자극을 인가하였을 때도 자극에 의해 망막신경절 세포의 반응이 유발되는 것을 확인하였다. APB-변성망막에서 전압의 크기를 2V로 고정하고 자극 지속시간을 $100{\sim}1,200{\mu}s$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극의 역치는 $300{\mu}s$에서 관찰되었으며 이는 정상망막의 결과와 같았다. 추후 APB-변성망막을 가지고 좀더 실험이 진행되어야 정상망막과 변성망막의 전하밀도에 관한 명료한 비교가 가능할 것이다.

  • PDF

하반신 마비환자의 FES 독립보행을 위한 근육 강화 프로그램 (FES Exercise Program for Independent Paraplegic Walking)

  • 강선화;강곤;최현주;김종문;정순열;정진상
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권1호
    • /
    • pp.69-80
    • /
    • 1998
  • 본 연구에서는 엑서사이즈 프로그램이 FES를 이용한 하반신 마비환자의 일어서기 및 보행에 미치는 영향을 고찰하였으며, 또한 주요 다리근육들의 전기자극에 대한 수축특성과 피로특성에 주안점을 두었다. 정상인 10명과 완전 하반신 마비환자 4명의 대퇴사두근에 연속적 혹은 간헐적으로 전기자극을 가하였고, 자극주파수는 20Hz와 80Hz로 하였다. 또 근육의 길이에 따른 피로현상을 살펴보기 위하여 무릎의 각도를 90$^{\circ}$와 150$^{\circ}$로 각각 고정한 뒤 무릎신근 토크를 측정하였다. 그 결과를 바탕으로 남자 하반신 마비환자의 대퇴사두근과 장딴지근에 지난 2년간 FES엑서사이즈를 시행하였다. 무릎신근의 근력이 체중을 지지하기에 충분하다고 판단되었을 때 FES 일어서기를 시작하였으며, 자세교환 연습을 거친 뒤 평행봉 혹은 워커를 잡고 정전압 자극기와 표면전극을 사용한 4 또는 6채널 자극으로 보행하도록 하였다. 마비된 근육은 정상인과는 반대로 최적길이 부근에서 상대적으로 급격한 피로를 나타내었고, 저주와 자극과 간헐 자극이 피로를 지연시키는 것을 확인할 수 있었다. 본 실험에 참가한 환자는 FES 엑서사이즈 프로그램을 실시한 결과, 근력이 초기의 10배 정도로 증가하였고, 피로지수는 초기의 절반 정도로 감소하였으며, 엑서사이즈 횟수를 매주 6일에서 7일로 바꾼 후 근력이 눈에 띄게 향상되었다. 환자 자신의 잔존능력도 향상되어 양쪽 무릎을 10cm정도 들어올릴 수 있게 됨으로써 보행시 스윙 단계에서 이 능력을 최대한 활용할 수 있었다. 현재 환자는 워커를 잡고 스스로 자극기의 스위치를 조작하면서 4채널 자극에 의하여 10m/min의 속도로 최대 약 2분 40초의 보행이 가능하다.

  • PDF