• Title/Summary/Keyword: Surface electrical stimulation

Search Result 99, Processing Time 0.028 seconds

Efficacy of Microcurrent Electrical Neuromuscular Stimulation with Different Types of Stimulating Electrodes (미세전류치료기 전극 종류에 따른 효능 비교)

  • Choi, Hyo-Jeong;Kim, Sung-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.3
    • /
    • pp.107-116
    • /
    • 2013
  • Objectives The purpose of this study was to evaluate the most effective stimulating electrode in Microcurrent electrical neuromuscular stimulation (MENS) for pain relief, and to apply to the treatment of Delayed onset muscle soreness (DOMS). Methods We included 45 participants who met the inclusion criteria. DOMS of both Triceps Surae Muscles were experimentally induced through eccentric contractions. 24-hours after induction of DOMS, who scored more than 40 mm in visual analogue scale (VAS) were randomly assigned into three groups (n=44). In 15 of them, needle electrodes were inserted into BL57, BL56. In 15 of them, surface electrodes were applied on the same points and the others were treated with manual acupuncture. The effects of pain relief were assessed by visual analogue scale (VAS), mechanical pain threshold (MPT), surface electromyography (SEMG). Results In VAS, group comparison had no significant difference after all treatments had done. The difference in VAS between the time before the treatment was started (Day 2) and after all treatments were completed was greater in Acupuncture group than that of needle-electrode group. In MPT, there was no significant difference among groups. Electrical contraction decreased significantly at 2nd before-after treatment comparison in needle-electrode MENS group. But fatigue scores were not significantly different between groups. Conclusions The results suggest that the types of electrodes has no significant effect on microcurrent therapy in DOMS.

Effects of TENS and Inhibitive Techniques on Spasticity in Cerebral Palsy: A Single-Subject Study (경피신경자극치료와 경직억제기술이 뇌성마비의 경직에 미치는 효과)

  • Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.4 no.1
    • /
    • pp.70-77
    • /
    • 1997
  • An A-B-A-C single subject research design was used to assess the effectiveness of transcutaneous electrical nerve stimulation(TENS) and inhibitive techniques on spasticity in a 10-year-old girl with cerebral palsy. Stimulation electrodes were placed over the sural nerve of the right leg. The standard method of cutaneous stimulation, TENS with impulse frequency of 100 Hz, was applied. Inhibitive techniques including stretch, antagonist contraction, and weight bearing were used. The tonus of the leg muscle was measured by means of a surface-EMG biofeedback unit. Visual analysis of data indicate that the child showed clinically significant reduction of spasticity in passive ankle movement following 30 minutes of TENS and inhibitive techniques application, respectively. The effect of TENS on spasticity inhibition was similar to that of inhibitive techniques. This result suggests that for this child with cerebral palsy, the application of TENS to the sural nerve may induce short-term post-stimulation inhibitory effects on the spasticity of cerebral palsy. Replication of this study with a more complex single-subject design involving more subjects is recommended to confirm this result.

  • PDF

Electrical Properties of Organic Thin Films by Deposition Type (유기박막의 누적형태에 따른 전기특성)

  • 송진원;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.287-290
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto y-type silicon wafer as x, y, z-type film. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V].

  • PDF

The Comparative Study on the Frequency of Transcutaneous Electrical Nerve Stimulation for Delayed-Onset Muscle Soreness (지연성 근육통에 대한 경피신경전기자극의 주파수별 효과 비교)

  • Park, Hyun-Gun;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.2
    • /
    • pp.63-72
    • /
    • 2013
  • Objectives : The aim of this study was to investigate difference of the effects of transcutaneous electrical nerve stimulation(TENS) with different frequencies in participants having delayed onset muscle soreness(DOMS). Methods : We recruited 36 healthy participants, but 3 of them were dropped out. They were randomly divided into 3groups : 3 Hz TENS(n=11), 100 Hz TENS(n=11) and sham TENS(n=11). DOMS of the both triceps surae muscle induced by repetitive concentric, ecentric exercise. The result measurements were pain perception(visual analogue scale, VAS), mechanical pain threshold(MPT) by pressure algometer, electrical contraction and fatigue by surface electromyography. The measurements were on first visit, before and after treatment except first. This study was prospective, randomized, controlled, single-blinded trial. Results : In 100 Hz TENS group, VAS was significantly decreased during whole session compared with 3 Hz and control group, and after each treatment, too. In 3 Hz TENS group, VAS was significantly decreased during whole session compared with control group, and after 2nd, 3rd treatment, too. In 100 Hz TENS group, MPT increased the most among 3 groups during whole session and after 1st treatment, but there were no statistical significances. Conclusions : Both 3 Hz and 100 Hz TENS improved delayed onset muscle soreness, but 100 Hz TENS group is more effective than 3 Hz TENS group.

Displacement Properties of Nano Structure Dendrimer

  • Song Jin-Won;Lee Kyung-Sup;Lee Woo-Ki;Choi Young-Il;Yoon Suk-Am;Choi Chung-Seog
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.28-32
    • /
    • 2005
  • In the Langmuir-Blodgett (LB) technique, a monolayer on the water surface is transferred onto a substrate, which is raised and dipped through the surface. From this, multilayers can be obtained in which constituent molecules are periodically arranged. The LB technique has attracted considerable interest in the fabrication of electrical and electronic devices. Many researchers have investigated the electrical properties of monolayer and multiplayer films. Dendrimers represent a new class of synthetic macromolecules characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The azobenzene dendrimer is one of the dendritic macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and ptoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current.

Breakdown Voltage and Electrical Characteristics of Organic Thin Film (유기박막의 파괴전압과 전기특성)

  • Song, Jin-Won;Kang, Yong-Chul;Kim, Hyung-Gon;Lee, Woo-Sun;Chung, Hun-Sang;Chang, Hee-Dong;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1497-1499
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 30 [mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto y-type silicon wafer as y-type film. In processing of a device manufacture. we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al. the number of accumulated layers are 9$\sim$21. Also. we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

Displacement Current Properties for Nano Structure Dendrimer (나노구조 덴드리머의 변위전류 특성)

  • Song, Jin-Won;Choi, Yong-Sung;Lee, Woo-Ki;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.52-54
    • /
    • 2006
  • In the Langmuir-Blodgett (LB) technique, a monolayer on the water surface is transferred onto a substrate, which is raised and dipped through the surface. From this, multi layers can be obtained in which constituent molecules are periodically arranged. The LB technique has attracted considerable interest in the fabrication of electrical and electronic devices. Many researchers have investigated the electrical properties of monolayer and multiplayer films. Dendrimers represent a new class of synthetic macromolecules characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The azobenzene dendrimer is one of the dendritic macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and ptoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current.

  • PDF

A Study on Electrical Properties of Dendrimer (덴드리머의 전기적 특성 연구)

  • Choi, Yong-Sung;Song, Jin-Won;Lee, Woo-Ki;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1330-1332
    • /
    • 2006
  • In the Langmuir-Blodgett (LB) technique, a monolayer on the water surface is transferred onto a substrate, which is raised and dipped through the surface. From this, multilayers can be obtained in which constituent molecules are periodically arranged. The LB technique has attracted considerable interest in the fabrication of electrical and electronic devices. Many researchers have investigated the electrical properties of monolayer and multiplayer films. Dendrimers represent a new class of synthetic macromolecules characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The agobenzene dendrimer is one of the dendritic macromolecules that include the azo-group exhibiting a photochromic character. Due to the Presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and ptoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current.

  • PDF

Displacement Current Characteristics of Nano-Structural Dendrimer (나노구조 덴드리머의 변위전류 특성)

  • Song, Jin-Won;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.358-359
    • /
    • 2006
  • In the Langmuir-Blodgett (LB) technique, a monolayer on the water surface is transferred onto a substrate, which is raised and dipped through the surface. From this, multilayers can be obtained in which constituent molecules are periodically arranged. The LB technique has attracted considerable interest in the fabrication of electrical and electronic devices. Many researchers have investigated the electrical properties of monolayer and multiplayer films. Dendrimers represent a new class of synthetic macromolecules characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The azobenzene dendrimer is one of the dendritic macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and ptoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current.

  • PDF

Effect of a Combined Functional Electrical Stimulation with Action Observation Training on the Upper Limb Global Synkinesis and Function of Patients with Stroke

  • Kang, Jeongil;Kim, Huikyeong;Jeong, Daekeun;Park, Seungkyu;Yang, Daejung;Kim, Jeho;Moon, Youngjun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.1
    • /
    • pp.2012-2020
    • /
    • 2020
  • Background: Multifaceted approaches will be needed, such as global synkinesis (GS) achieve functional improvements in the arms of stroke patients from involuntary movements during exercise. Objective: To identify changes in arm GS and muscle activity, functional evaluation and the correlation with variables through action observation training, combined with functional electrical stimulation (FES), thereby verifying the effect on stroke patients. Design: A quasi-experimental study. Methods: The subjects of this study were 20 stroke patients who were divided into two groups: Control group (n=10) and experimental group (n=10). Before the intervention, arm GS and muscle activity were measured using surface electromyography (EMG), and arm function was evaluated using the Fugl-Meyer Assessment (FMA) scale. At the end of the intervention, which lasted 4-wk, arm GS and muscle activity were measured again using the same scale. Results: There was a decrease statistically significant difference in GS during the bending action in experimental group (P<.01). Both groups showed a significant difference increased only in the activity of the anterior deltoid (AD) and biceps brachii (BB) (P<.05). The results of the arm functional assessment revealed a significant difference increase in both groups (P<.05). In the between-group comparison, there was a significant difference decrease in GS during the bending action (P<.05). Only the muscle activity of the AD and BB were significantly increase different (P<.05). There was a significant between-group difference increase in the arm functional assessment (P<.05). There was a positive correlation between GS and muscle activity on the FMA in the control group (r=.678, P<.05). In experimental group, GS during the bending arm action exhibited a negative correlation (r=-.749, P<.05), and the muscle activity of the AD and BB showed a positive correlation (r=.701, P<.05). Furthermore, in experimental group, the activity of the extensor carpi radialis increased, and the activity of the flexor carpi radialis decreased, which exhibited a negative correlation (r=-.708, P<.05). Conclusion: These results suggest that brain plasticity could be more efficiently stimulated by combining surface stimulation in the affected arm of stroke patients.