• Title/Summary/Keyword: Surface electrical stimulation

Search Result 99, Processing Time 0.04 seconds

The Effects of Biofeedback Fusion Postural Control Training using Functional Electrical Stimulation on the Muscle Activity and Balance Ability of the Stroke Patient (기능적 전기 자극을 이용한 생체되먹임 융합 자세조절 훈련이 뇌졸중 환자의 근활성도와 균형 능력에 미치는 영향)

  • Kim, Je-Ho;Uhm, Yo-Han
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.319-327
    • /
    • 2019
  • The muscle activity and balance ability of the acute stroke patient has been checked by the functional electrical stimulation using biofeedback fusion postural control training in this study. Functional electrical stimulation using biofeedback fusion postural control training have been implemented on 15 trainees and general biofeedback fusion postural control training have been implemented on another 15 trainees for 30 minutes at 5 times per week during 8 weeks, and vastus lateralis, vastus medialis, rectus femoris and biceps femoris have been measured using the biceps femoris to evaluate the muscle activity of the lower extremity. The moving surface area, whole path length and limited of stability have been measured using biorecue to measure the balance ability. There was statistically meaningful difference on the vastus lateralis, vastus medialis, rectus femoris and biceps femoris in the muscle activity of the lower extremity and there was statistically meaningful difference on surface area, whole path length and limited of stability in the balancing ability. Based on above, it is realized that the functional electrical stimulation using biofeedback fusion postural control training is more effective than the general biofeedback fusion postural control training on the improvement of the muscle activity of the lower extremity and the balance ability.

The Effects of Functional Electrical Stimulation Combined with Action Observation on Sensorimotor Cortex

  • Kim, Ji Young;Park, Ji Won;Kim, Seong Yoel
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.4
    • /
    • pp.164-168
    • /
    • 2017
  • Purpose: Functional electrical stimulation (FES) is a device that activates the sensorimotor cortex through electrodes attached to the surface of the skin. However, it is difficult to expect positive changes if the recipient is not attentive to the motion. To complement the perceived cognitive limitations of FES, we attempted to investigate the changes of sensorimotor cortex activity by simultaneously providing action observation with FES. Methods: Electroencephalogram was measured in 28 healthy volunteers. Relative band power over the sensorimotor cortex was analyzed and compared in three conditions: during rest, during FES alone, during action observation with FES. Results: The results showed significant differences in each relative band power. Relative alpha power and relative beta power were the lowest by application of FES combined with action observation, while the relative gamma power was the highest. Conclusion: These results suggest that combining FES with observation could be more effective than FES alone in neurorehabilitation.

Development of surface electrode type electrical stimulator or supporting walk function in foot drop patients (족하수 환자에서의 보행기능 보조를 위한 표피 자극형 전기자극기 개발)

  • Lim, S.K.;Jeong, H.C.;Kim, K.G.;Jin, D.B.;Park, B.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.9-13
    • /
    • 1997
  • The present study was designed to develop the functional electrical stimulation system in order to restore motor function of paralytic patients. We attempt to establish adequate stimulus parameters for the recovery of work unction in lower limb paralysis patients and to develop the electrical stimulation system, which is effective to protect foot drop in these patients. In our animal and human experiment, adequate stimulus condition for surface electrode on the lower limb were 0.2-0.3ms at the duration and 50 Hz, which contain 600Hz train pulse. This parameter has efficiently prevented the foot drop from lower limb paralysis, decreased muscle fatigue and induced powerful contraction of lower limb muscle.

  • PDF

Effects of Neon Plasma Emission on Optical Properties of Phosphor Layers in Surface-Type Alternate Current Plasma Display Panel

  • Jang, Sang-Hun;Cho, Ki-Duck;Tae, Heung-Sik;Park, Lee-Soon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.171-174
    • /
    • 2000
  • This study uses neon and xenon gas mixture discharges to determine the effects of the neon plasma emission on the characteristics of visible emission from the stimulation of the red, green, blue(RGB) phosphor layers in a surface-type alternate current plasma display panel(AC PDP). With a mixture of less than 2% xenon to neon, it is found that the luminance changes in the visible emission of the phosphor layers are similar to those of the neon plasma emission. In the range of xenon mix ratio from 2 to 5%, the luminance of the red, green, blue(RGB) phosphor layers decreases with a decrease in the neon plasma emission intensity. However, with a mixture of above 5% xenon to neon, the luminance of the red, green, blue(RGB) phosphor layers increases regardless of a decrease in the neon plasma emission intensity. Furthermore, the color purity of the red, green, blue(RGB) phosphor layers improve as the neon plasma emission intensity decreases. Accordingly, it is concluded that the optical properties of the phosphor layers, including color purity and luminance, depend on the neon plasma discharge emission as well as the visible emission from the stimulation of the phosphor layers.

  • PDF

Analysis of Surface EMG Power Spectrum and Muscle Fatigue Depending on the Variable of Neuromuscular Electrical Stimulation (표면근전도를 이용한 신경근 전기자극 치료변수에 따른 근피로도 분석)

  • Kim, Gi-Won;Kim, Junesun
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.280-289
    • /
    • 2014
  • Purpose: This study was conducted in order to determine the stimulation variables which should be considered when neuromuscular electrical stimulation (NMES) is applied for a muscle under the normal innervation to minimize muscle fatigue and increase force-generating ability. Methods: A total of 23 healthy men participated in the study and all subjects were randomly assigned to the 1:1 group, 1:3 group, 1:5 group, and control group with on-off ratio of NMES. The subjects performed a fatigue task, consisting of 10 times of isometric contraction sustained by NMES. NMES using Russian current stimulation was applied to muscle fatigue and divided into three sessions by pulse frequency (10 bps, 30 bps, 90 bps). The EMG was recorded using an MP 100 system from the quadriceps femoris muscle in four groups. Results: The differences of delta MdF and delta MF of between on-off ratio groups of 10 bps, 30 bps, and 90 bps pulse frequencies were very significant (p<0.05). According to the results of post hoc of 10, 90 bps, it was greater in the 1:1 group and the 1:3 group compared with the 1:5 group, and no fatigue was observed in the control group. In 30 bps, it was greater in the 1:1 group compared with 1:3, 1:5, and control group (p<.05). Conclusion: Among NMES variables to minimize muscle fatigue, the larger on-off ratio by pulse frequency showed the lower muscle fatigue. Therefore, on-off ratio needs to be great enough, and will be more efficient with the frequency 30 bps rather than of 10 bps and 90 bps.

Effect of Microcurrent Stimulation at Hand Somatic Acupuncture Points on Experimental Pain Threshold (미세전류가 수부체성경혈점의 실험적 통증 역치에 미치는 영향)

  • Cho Jung-Sun;Chen Jae-Kyun;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.85-93
    • /
    • 1994
  • The purposes of this study were 1) to examine the effects of microcurrent electrical neuromuscular stimulation 2) to compare surface electrode with needle electrode at somatic acupuncture points on experimental pain threshold measured at the distal end of the radius 3) to determine the changes in effect over time. A total of sixty healthy adult male and female subjects were assigned randomly to one of two experimental group or to a control group. Group 1(n=20) received MENS(Microcurrent Electrical Neuromuscular Stimulation) with surface electrode. Group 2(n=20) received HENS with needle electrode. Group 3(n=20) received no MENS. It measured experimental pain threshold at the wrist on pretreatment, 0 min after treatment. 15 min after treatment, 30 min after treatment in two experimental group. The results were as follows: 1. Experimental pain thresholds were higher in males than females(P<0.01). 2. Only the experimental group exhibited a significant increased in pain threshold after MENS treatment(P<0.05). 3. Surface electrode group increased significant pain threshold 0 min, 15 min after treatment, but greatly decrease 30 min after treatment. 4. Needle electrode group increased significant pain threshold 0 min, 15 min after treatment, but decrease 30 min after treatment. The results suggest that MENS applied to appropriate somatic acupuncture point can increase pain threshold. Further research is needed to assess the effects of greatly variety intensity of MENS of pain sufferes.

  • PDF

Functional Electrical Stimulation for Rehabilitation of a Shoulder Joint (견관절 재활훈련을 위한 기능적 전기자극)

  • Jeon, Jae Hyeon;Kim, Jin Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1121-1127
    • /
    • 2013
  • This study deals with experimental studies on electromyogram (EMG) measurements and functional electrical stimulation (FES) for the rehabilitation of a shoulder-joint. Based on the structure, motion, and main functions of the musculoskeletal system in a shoulder-joint, the muscles playing a major role for the motion in the sagittal plane were selected for the experiment. First, the surface electromyogram of the main muscles was measured according to the joint angle. The results showed that the change in the surface EMG was linearly proportional to the change in the joint angle. Second, the joint angle was measured during FES at shoulder muscles. The results showed that the joint angle increased as the FES current increased in a certain range of FES. It was confirmed that the willingness of muscles to move could be detected by measuring EMG and that the generation of muscle tension could be assisted by FES for active rehabilitation.

Changes of Upper Trapezius Muscle Activity and EMG Gap After Transcutaneous Electrical Nerve Stimulation in Subjects With Myofascial Pain Syndrome (경피신경전기자극 후 상부 승모근 활성도와 EMG gap의 변화)

  • Koh, Eun-Kyung;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.37-50
    • /
    • 2003
  • The purpose of this study was to compare visual analogue scale (VAS), pain threshold (PT), $%RMS_{RVC}$, and EMG gaps before and after applying transcutaneous electrical nerve stimulation (TENS) on the upper trapezius muscle at the patients with myofascial pain syndrome (MPS). The subjects were 4 men and 10 women composed of both the inpatients and outpatients who were diagnosed as MPS at Wonju Medical Center. VAS and PT measurements were performed to assess the subjective pain level. The reference voluntary contraction (RVC) test was performed for 15 seconds for normalization on the bilateral trapezius muscle using surface electromyography (sEMG). After 3-minute resting time, the EMG signal was recorded while performing a typing activity for 2 minutes and then TENS was applicated with a comfortable intensity for 10 minutes. The EMG activity of the upper trapezius muscle was recorded during typing for 2 minutes. The results of study were as follows: 1) VAS score was significantly decreased on the more painful side after treatment, however, it was not significantly different on the less painful side. 2) PT was increased after treatment on both sides, however, it was not significantly different between before and after the TENS application. 3) The EMG activity during typing was significantly decreased after treatment, and 4) The EMG gaps were significantly increased after TENS treatment compared to before it. Consequently, the study showed that TENS was effective in decreasing VAS, $%RMS_{RVC}$, and in increasing EMG gaps. The EMG gap analysis could be a useful method to measure pain in patients with MPS in the upper trapezius.

  • PDF

Diagnostic Technique for Mold Transformer Windings using Thermal Image (열화상을 이용한 몰드변압기 권선표면 진단)

  • Lim, Y.B.;Jung, J.W.;Jung, J.S.;Ko, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.107-109
    • /
    • 2005
  • Temperature distribution measured to estimate condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current one. Because a passive thermography without the external thermal stimulation shows the difference in surface temperature between the object and back ground, the results can apply only to the estimation or the monitoring for the condition of terminal loose and the overload pertaining to the rise in temperature. However, a thermal flow in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents the nondestructive testing using the behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.