• Title/Summary/Keyword: Surface coil

Search Result 313, Processing Time 0.028 seconds

Study on Coil Insulation of HTS Transformer with Simulated Electrode (고온초전도 코일의 모의 전극계에서의 절연연구)

  • 정종만;백승명;이정원;곽동순;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.420-423
    • /
    • 2002
  • In this paper the characteristics of surface flashover for high temperature superconducting transformer(HTS) was discussed. The transformer, will be developed in the shell type with double pancake coil, isn't developed yet in the world. We conducted experiment of surface flashover that could occur in the windings of the transformer. First, we distinguished the surface flashover with electrode alignment into two type, such as parallel and vertical, and then compared with each characteristics of surface flashover. And the surface flashover with metallic particle was tested, it was also affected by the particle position. .

  • PDF

3T MR Imaging에 적합한 RF Surface Coil의 개발: 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.73-73
    • /
    • 2003
  • 목적: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다.

  • PDF

Numerical and experimental analysis of temperature distribution in TEFC induction motor (전폐형 유도전동기의 온도분포에 관한 수치 및 실험적 해석)

  • Yun, Myeong-Geun;Go, Sang-Geun;Han, Song-Yeop;Lee, Yang-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.457-472
    • /
    • 1997
  • We studied the temperature distribution and heat transfer characteristics of TEFC induction motor with thermal network program for more efficient design and better cooling performance of it. We knew the characteristics and the windage loss of outer cooling fan from fan test experiments. Frame axial and peripheral heat transfer coefficients and endwinding heat transfer coefficient were measured by various model experiments and then, compared with other experimental results. Frame was the main heat transfer surface, load-side and fan-side surface were not thermally symmetric from the heat flux distribution analysis. Steady and unsteady temperature distributions were measured by real motor experiments. From the results, we knew that rotor surface temperature was higher than coil temperature and the hottest spot in the coil was loadside endwinding outside surface. We compared the simulation results with those of real motor test and the two results showed a good agreement.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Tension/Heat/Thermal Deformation Analysis of a Cold Coiled Strip in Coiling Process (냉연 판재의 권취공정에 있어서 장력/열/변형 해석)

  • 정영진;이규택;강충길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.39-43
    • /
    • 2002
  • A new model for heat transfer and thermal deformation analysis according to strip mm in coiling process has been proposed. Finite difference analyses for heat transfer of cold rolled coil have been carried out under various coiling tensions and strip crown using the equivalent thermal conductivity for the radial direction of cold rolled coil which is a function of strip thickness, surface characteristics and compressive pressure. The compressive pressure is calculated from a equation expressed as a function of hoop stress and coil tension considering strip mm obtained by experiment. Finite element method for thermal deformation of cold rolled coil has been performed to investigate the effects of the strip crown, the coil tension and temperature. From these analyses, it is found that the axial inhomogeneity of thermal deformation is increased as the strip crown, compressive pressure, and temperature drop in cold coiled strip increase.

  • PDF

Home-built Solid-state NMR Probe for Membrane Protein Studies

  • Kim, Yong-Ae;Hwang, Jung-Hyun;Park, Jae-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1281-1283
    • /
    • 2003
  • Proteins in highly oriented lipid bilayer samples are useful to study membrane protein structure determination. Planar lipid bilayers aligned and supported on glass slide were prepared. These stack of glass slide with planar lipid bilayers are not well fit for commercial solid-state NMR probe with round coil. Therefore, homebuilt solid-state NMR probe was built and used for a stack of thin glass plates and RF coil is wrapping directly around the flat square sample. The overall filling factor of the coil is much better and the large surface area enhances the extent to orientation by providing uniform environments for the phospholipids and the high ratio of circumference to area reduces edge effects. $^1H\;and\;^{15}N$ double resonance probe for 400 MHz NMR (9.4T) with a flat coil (coil size: 11 mm ${\times}$ 20 mm ${\times}$ 4 mm) is constructed and tested.

Development and Characteristics of a New Insulator between Turns of Superconducting Coil (초전도 Coil의 새로운 turn간 절연재료의 개발 및 특성)

  • 박영욱;이동성;이정원;곽동순;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.26-29
    • /
    • 2002
  • Polyimide-epoxysilane (coupling agent) composites were reacted with oligomeric PDMS, a condensation product of difunctional silane, by a sol-gel process and were then dried into films. And then, the surface, mechanical, and electric properties were measured. The study showed that PDMS existed in the polymide matrix by the use of FT-IR. In the mechanical properties, the maximum elongation and toughness was increased in the polyimide with silane-groups. But the maximum tensile strength was slightly decreased. And the intensive dispersion of the silane-groups on the surface of polyimide was ascertained through XPS measurement. In the electric properties. AC break down voltage was increased by increasing the amount of difunctional silane. This experiment showed that PDMS added polyimide had better mechanical and electric properties than classical materials.

3T MR Imaging에 적합한 RF Surface Coil의 개발 : 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.48-48
    • /
    • 2003
  • Abstract: 현대 질병의 최종진단은 세포수준의 해부형태학적 연구가 일반적이며 광학현미경이나 전자현미경을 이용한 병리조직학적 소견을 바탕으로 진단되어지고 있다. 이러한 진단에는 In vivo 검사가 거의 불가능하여 주로 생검을 통한 연구만 수행되고 있어 진단함에 있어 단계적인 불편이 초래될 뿐만 아니라 악성 종양의 전이를 유발시킬 수 있고 또한 생리 및 생화학적 분석이 어렵다. 이러한 문제점을 해결하기 위해 고분해능의 RF Surface Coil을 개발하여 In vivo 및 비침습적인 방법인 MR Technology를 이용하고자 한다. Introduction: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다. Method: 고분해능의 RF Surface Coil을 제작하여 3T MR 장비에서 피부 미세구조연구에 보다 적합하도록 In vivo 및 In vitro 실험을 수행하였다. In vitro 실험은 In vivo 연구를 위한 여러 parameter들을 최적화하기 위한 기초 실험을 하였고 다양한 팬톰들을 이용하여 Tl 강조영상, T2 강조영상을 획득하였으며, SNR을 높이기 위한 개선에 대한 연구를 수행하였다. In vivo 실험은 정상피부에서 다양한 부위에 대한 피부영상의 예비 연구를 수행하였다. Result and Discussion: 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준에서 가능해짐으로써 질병의 정확한 진단이 가능해지게 될 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002)) 지원아래 수행되었다.

  • PDF

Study on the Critical Current of Field Coil for High Temperature Superconducting Motor (고온초전도 전동기용 계자코일의 임계전류 연구)

  • Jo, Young-Sik;Sohn, Myung-Whan;Baik, Seung-Kyu;Kwon, Woon-Sik;Lee, Eon-Yong;Kwon, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.873-875
    • /
    • 2003
  • It is well known that $I_c$ (critical current) in HTS tape is more sensitive to $B{\perp}$ (magnetic field amplitude applied perpendicular to the tape surface) than to B// (magnetic field amplitude applied parallel to the tape surface). Thus, the magnitude of $B{\perp}$ at HTS tape is important to the design of HTS motor, because it determines the operating current. In addition, the $I_c$ of HTS field coil is determined by not only the $B{\perp}$ but also stress and strain condition at given operating temperature. Therefore, at the stage of field coil design, stress and strain conditions should be considered because when the HTS tape is handled, it is necessary to know the limiting values of loading, bending and twisting to avoid any damages. The $I_c$ of field coil is calculated by 3D analysis and measured through experiments considering the $B{\perp}$ and the margin of contacts loss.

  • PDF

Analysis of Blood Flow after Coil Embolization in Anterior Cerebral Artery Aneurysm (전산해석을 통한 전대뇌동맥류 코일 색전술 후 혈류 유동 분석)

  • Donghwi Kim;Jeonghoon Yoon;Changyong Lee;Junwoo Jae;Dongmin Kim;Youngoh Bae;Jinyul Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.80-93
    • /
    • 2023
  • We performed numerical simulations of blood flow in an arterial cerebral artery aneurysm to investigate the hemodynamic behavior after coil embolization. A patient-specific model was created based on CTA data. We also conducted the coil embolization simulation to obtain the coil placement within the aneurysm. Blood was assumed to be an incompressible Newtonian fluid, and both the vessel and coil were considered rigid walls. The pulsatile boundary condition was applied at the inlet, and the outflow boundary conditions were used at the outlets. Our findings demonstrated that the coil embolization significantly reduces the blood volume flowrate entering the aneurysm by effectively blocking the inflow jet, leading to a decrease in both TAWSS and WSS, especially at the systolic peak in the impingement zone. While several high OSI regions disappeared over the aneurysm surface, we observed high OSI regions with a relatively small area where the coil did not completely occlude the aneurysm. Overall, these results quantitatively analyzed the effectiveness of coil embolization by focusing on hemodynamic indicators, potentially preventing aneurysm rupture. The present work could contribute to the development of patient-specific coil embolization.