• Title/Summary/Keyword: Surface check

Search Result 505, Processing Time 0.033 seconds

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).

The Parallelization Effectiveness Analysis of K-DRUM Model (분포형 강우유출모형(K-DRUM)의 병렬화 효과 분석)

  • Chung, Sung-Young;Park, Jin-Hyeog;Hur, Young-Teck;Jung, Kwan-Sue
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.4
    • /
    • pp.21-30
    • /
    • 2010
  • In this paper, the parallel distributed rainfall runoff model(K-DRUM) using MPI(Message Passing Interface) technique was developed to solve the problem of calculation time as it is one of the demerits of the distributed model for performing physical and complicated numerical calculations for large scale watersheds. The K-DRUM model which is based on GIS can simulate temporal and spatial distribution of surface flow and sub-surface flow during flood period, and input parameters of ASCII format as pre-process can be extracted using ArcView. The comparison studies were performed with various domain divisions in Namgang Dam watershed in case of typoon 'Ewiniar' at 2006. The numerical simulation using the cluster system was performed to check a parallelization effectiveness increasing the domain divisions from 1 to 25. As a result, the computer memory size reduced and the calculation time was decreased with increase of divided domains. And also, the tool was suggested in order to decreasing the discharge error on each domain connections. The result shows that the calculation and communication times in each domain have to repeats three times at each time steps in order to minimization of discharge error.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Patch Graft of the Canine Esophagus (식도이식에 관한 실험적 연구)

  • Ha, Gye-Sik
    • Journal of Chest Surgery
    • /
    • v.2 no.2
    • /
    • pp.167-167
    • /
    • 1969
  • Two groups of esophagus graft were done in canine esophagus in 34 adult mongrel dogs. For the first group segmental replacement graft was done with fresh autologous pericardium tube, and for the second, patch graft was done utilizing fresh autologous pericardium, fresh homologous pericardium,and dacron piece. All eight dogs in the first segmental replacement graft group died 2 to 5 days after operation with severe empyema caused by anastomosis disruption. Among 26 patch graft dogs 2 died during operation and 7 died 13 to 18 days after operation. For the 17 long-term patch grafted survivors esophagography and postoperative weight check were done. Postoperative stool was collected and examined for dacron patch excretion. One, two, three, and four months postoperative long-term survivors were sacrificed to obtain specimens in each group respectively and the following observations were made.I. Survival; Autologous pericardium patch group showed no mortality but in homologous pericardium and dacron patch group only two thirds were long-term survivors. II. Postoperative swallowing; There was no case which demonstrated postoperative dysphagia. About half of the cases showed postoperative weight increase and in only 3 cases weight decrease followed operation. III. Dacron patch was excreted in the stool 8 to 23 days after operation. Animals which excreted dacron patch up to 9 days after operation all died of empyema due to anastomosis disruption.IV. Postoperative esophagogram; All esophagograms in each group showed no leakage of barium, no passage disturbances and no remarkable stenotic signs.V. Morphological findings; [A] Macroscopical findings; In one month group specimens of each group dense adhesion with surrounding structures was noted and luminal surface was smooth with contraction of the patched area. In two month groups anastomosis sutures were still exposed but patched area showed lesser abnormality. In three to four months groups sutures were covered completely and patched area showed only very slight signs of contraction. [B] Microscopic findings; In one month group luminal surface of the replaced tissue [transplanted tissue] showed almost complete epithelial covering that is composed of several layers of squamous cells with no evidence of keratinization. Basement membrane was also well distinct throughout. Slight to minimal inflammatory cells comprising of large mononuclears, lymphocytes and plasma cells were observed in the subepithelial fibrous stroma consisted entirely of loose fibrous tissue containing many newly formed capillaries and fibroblastic proliferation. Scattered suture granulomas were found, few of which became acutely inflamed. In two months group repairing process progressed with lesser degree of inflammatory cell infiltration and young capillary proliferation. Fibrous tissue was more matured showing even focal collagenization.Suture granuloma persisted but with lesser reactive changes. Epithelial covering was that of a mature non-keratinizing stratified squamous epithelium. In three and four months groups the replaced area showed essentially similar histological findings. However, subepithelial stroma still consisted entirely of connective tissue without evidence of smooth muscle regeneration. In this group, inflammatory cell infiltration was minimal or negligible. Among these patch materials autologous pericardium group showed the most satisfactory repairing process.The above mentioned results may signify the feasibility of autogenous pericardium patch graft in clinical esophageal surgery.

Patch Graft of the Canine Esophagus (식도이식에 관한 실험적 연구)

  • 하계식
    • Journal of Chest Surgery
    • /
    • v.2 no.2
    • /
    • pp.168-186
    • /
    • 1969
  • Two groups of esophagus graft were done in canine esophagus in 34 adult mongrel dogs. For the first group segmental replacement graft was done with fresh autologous pericardium tube, and for the second, patch graft was done utilizing fresh autologous pericardium, fresh homologous pericardium,and dacron piece. All eight dogs in the first segmental replacement graft group died 2 to 5 days after operation with severe empyema caused by anastomosis disruption. Among 26 patch graft dogs 2 died during operation and 7 died 13 to 18 days after operation. For the 17 long-term patch grafted survivors esophagography and postoperative weight check were done. Postoperative stool was collected and examined for dacron patch excretion. One, two, three, and four months postoperative long-term survivors were sacrificed to obtain specimens in each group respectively and the following observations were made. I. Survival; Autologous pericardium patch group showed no mortality but in homologous pericardium and dacron patch group only two thirds were long-term survivors. II. Postoperative swallowing; There was no case which demonstrated postoperative dysphagia. About half of the cases showed postoperative weight increase and in only 3 cases weight decrease followed operation. III. Dacron patch was excreted in the stool 8 to 23 days after operation. Animals which excreted dacron patch up to 9 days after operation all died of empyema due to anastomosis disruption. IV. Postoperative esophagogram; All esophagograms in each group showed no leakage of barium, no passage disturbances and no remarkable stenotic signs. V. Morphological findings; [A] Macroscopical findings; In one month group specimens of each group dense adhesion with surrounding structures was noted and luminal surface was smooth with contraction of the patched area. In two month groups anastomosis sutures were still exposed but patched area showed lesser abnormality. In three to four months groups sutures were covered completely and patched area showed only very slight signs of contraction. [B] Microscopic findings; In one month group luminal surface of the replaced tissue [transplanted tissue] showed almost complete epithelial covering that is composed of several layers of squamous cells with no evidence of keratinization. Basement membrane was also well distinct throughout. Slight to minimal inflammatory cells comprising of large mononuclears, lymphocytes and plasma cells were observed in the subepithelial fibrous stroma consisted entirely of loose fibrous tissue containing many newly formed capillaries and fibroblastic proliferation. Scattered suture granulomas were found, few of which became acutely inflamed. In two months group repairing process progressed with lesser degree of inflammatory cell infiltration and young capillary proliferation. Fibrous tissue was more matured showing even focal collagenization. Suture granuloma persisted but with lesser reactive changes. Epithelial covering was that of a mature non-keratinizing stratified squamous epithelium. In three and four months groups the replaced area showed essentially similar histological findings. However, subepithelial stroma still consisted entirely of connective tissue without evidence of smooth muscle regeneration. In this group, inflammatory cell infiltration was minimal or negligible. Among these patch materials autologous pericardium group showed the most satisfactory repairing process. The above mentioned results may signify the feasibility of autogenous pericardium patch graft in clinical esophageal surgery.

  • PDF

Creep Behaviours of 9% Ni Alloy (Ni 합금강의 크리프 거동)

  • Hwang, Kyung-Choong;Kim, Jong-Bae;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To observe the high temperature creep test and the fracture surface of the samples of 9% Ni alloy steel generally used for all kinds of mahine parts and predict the durability of that by determining a constant of C with a Larson-Miller variable. Methods: The equipment of this test was made into lever-beam style designed by Andrade and F. Garofalo et al.. The condition of creep test was set under 16 kinds of conditions after fixing 4 kinds of temperature condition and 4 kinds of stress condition to check how it effects the samples. Results: The temperature of creep test was increased, the stress index (n) of creep deformation was gradually decreased from 3.97 to 3.55. The activation energy of creep deformation was decreased from 90.39 to 83.64 kcal/mol when the stress was increased. A constant of C value by calculation of larson-Miller variable was about 22 and if temperature for use is suggested, the durability could be calculated. Conclusions: By analyzing the fracture phenomenon and suggesting the observation result of the fracture surface of the samples and creep test of 9% Ni alloy steel, the basic design data for the practical use of accessories in the field of equipment could be constructed and used to predict the durability of the equipment.

  • PDF

Studies on The Effects of Several Methods Irrigation Control Affecting The Growth and Yields of Rice Plants and Saving the Irrigation Water (관개조절의 몇가지 방식이 수함의 생육 및 수량과 관개수절약에 미치는 영향에 관한 연구)

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.3
    • /
    • pp.2322-2341
    • /
    • 1971
  • The studies were conducted to determine the methods of irrigation control which is not only able to save the irrigation water as a adaptable measures for the insufficient irrigation water and the drought but also increase the yields of rice, in the paddy field which shows over percolating tendency through the couple years of 1968 and 1969 at Suwon. These experiments were carried with late maturing rice variety, Norim No. 6 and the major treatments in this experiments were filling the clay under surface soil, periodic irrigation and lining the Vinyl under the surface soil and three replicated completely randomized design was employed. Results obtained will be summarzed as follows. 1. Through the couple years, the plots tilled the clay under 15cm of the surface soil saved the irrigation water by 364% to 45% and 78% to 88% respectively. Particulary, the plot of filling the clay with 9cm thick under 15cm of the surface soil, saved the amount of irrigation water by 45% to 88% and also increased yields by 12% to 20% through the couple years. 2. The plots in which amount of 40mm of irrigation water is irrigated periodically from 5 to 8 days at the stages of tillering and ripening, saved theamount of irrigation water by 41% to 55% and also increased yields by 10% to 16% respectively through the couple years. 3. The plot lined the Vinyl under 15cm of the surface soil, saved the amount of irrigation water by 75% to 88% in accordance with the size of hole. The plot of lining the Vinyl with $3cm/m^2$ hole yielded almost same as the check plot, but in the case of lesser hole than above yielded less. 4. The plots inserted the Vinyl paper in 57cm depth and with 6cm height from the soil surface around the plot to prevent the ridge percolation reduced the amount of percolation by 25% to 33%. 5. The plot filled the wheat straw with 6cm thick under 15cm of the surface soil increased yields by 30% in former year but opposite results were gained in later year. 6. Generally, yields and yield components such as number of spikes of spikes per hill and number of grains per spike were decreased in 1969. These faots are considered to depend upon the rainy and cold weather in the stages of vigorous tillering and less sunshine in the stages of ripening. 7. The variation of characters among the plots will be summarized as follows. (1) Tallerplant height was found in the plots of clay filling and irrigation control. (2) longer culm length and higher yields were founds in the plots filled the clay with 9cm thick and controled the irrigation periodically froir 7 to 8 days. (3) Length of spike increased generally with yields but opposite tendency was found also. (4) Number of spikes per hill increased with yields in the plots of irrigation control. (5) Number of grains per spike increased with yields in the plots filled the clay with 9cm thick and controled irrigation periodically from 5 to 8 days. (6) Tendency of variation of 1000 grain weight is similar to Number of grains per spike. (7) Percentage of complete grains increased in the plot of clay filling and irrigation control.

  • PDF

Effects of Post Individualities on Treatability of Small Diameter Japanese Larch (Larix Leptolepis) with ACQ and CCA (낙엽송 원주상 소경목의 원목성상과 방부 처리성)

  • Kim, Yeong-Suk;Hong, Soon-Il;Yun, Jeong-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.52-60
    • /
    • 2006
  • This study investigated how wood properties (i.e., annual rings, sapwood, heartwood, and cracks) might affect preservative treatment in Japanese larch (Larix leptolepis) round-wood product. We specially focused on small-diameter (~10 cm diameter) wood that is commercially sold in market. Among 100 wood samples, the groups of sample with 13~16, 17~20 annual rings represented 33 and 27 in each frequency, while 2~3 and 4~5 mm annual ring width accounted for 72 and 68 in frequency. More than a half (54%) of wood samples contained a mix of heartwood and sapwood in its surface. The rest (46%) had only heartwood exposed in the wood surface. A wide range of checks were showed in the wood samples, but the highest frequency was observed in samples with 1~6 surface (1~14 mm in size) checks and 1~4 end-grain (8~14 mm in size) checks in each round-wood sample. Pressure treatment resulted in a wide range of penetration of ACQ (Alkaline Copper Quat) into the wood, showing $4.3{\pm}4.19mm$ penetration in the wood samples contained a mix of heartwood and sapwood in its surface. However preservative treatment was much less effective for the heartwood only wood samples, ranging average 1.3 mm with ACQ and 1.1 mm with CCA (Chromated Copper Arsenate). These penetration results shown in heartwood samples did not meet the penetration standard that is required for H3 by the Korean Forest Service in relation to wood preservation treatment. These low penetration results were not significantly improved even if we incised wood samples to improve treatment effect, showing only small increase of 0.7 mm with ACQ and 0.6 mm with CCA. When preservative treatment was tested with heartwood, penetration of preservatives decrease with increase of annual rings per a cross-section area (r=0.5345). We also found that the length and number of check had no effect on preservative treatment, showing r=0.1301 and r=0.1802, respectively.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Comparisons of 1-Hour-Averaged Surface Temperatures from High-Resolution Reanalysis Data and Surface Observations (고해상도 재분석자료와 관측소 1시간 평균 지상 온도 비교)

  • Song, Hyunggyu;Youn, Daeok
    • Journal of the Korean earth science society
    • /
    • v.41 no.2
    • /
    • pp.95-110
    • /
    • 2020
  • Comparisons between two different surface temperatures from high-resolution ECMWF ReAnalysis 5 (ERA5) and Automated Synoptic Observing System (ASOS) observations were performed to investigate the reliability of the new reanalysis data over South Korea. As ERA5 has been recently produced and provided to the public, it will be highly used in various research fields. The analysis period in this study is limited to 1999-2018 because regularly recorded hourly data have been provided for 61 ASOS stations since 1999. Topographic characteristics of the 61 ASOS locations are classified as inland, coastal, and mountain based on Digital Elevation Model (DEM) data. The spatial distributions of whole period time-averaged temperatures for ASOS and ERA5 were similar without significant differences in their values. Scatter plots between ASOS and ERA5 for three different periods of yearlong, summer, and winter confirmed the characteristics of seasonal variability, also shown in the time-series of monthly error probability density functions (PDFs). Statistical indices NMB, RMSE, R, and IOA were adopted to quantify the temperature differences, which showed no significant differences in all indices, as R and IOA were all close to 0.99. In particular, the daily mean temperature differences based on 1-hour-averaged temperature had a smaller error than the classical daily mean temperature differences, showing a higher correlation between the two data. To check if the complex topography inside one ERA5 grid cell is related to the temperature differences, the kurtosis and skewness values of 90-m DEM PDFs in a ERA5 grid cell were compared to the one-year period amplitude among those of the power spectrum in the time-series of monthly temperature error PDFs at each station, showing positive correlations. The results account for the topographic effect as one of the largest possible drivers of the difference between ASOS and ERA5.