• 제목/요약/키워드: Surface Temperatures

검색결과 2,434건 처리시간 0.036초

저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구 (An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity)

  • 강한용;이동석;김병철
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

A Study on Comparison of Satellite-Tracked Drifter Temperature with Satellite-Derived Sea Surface Temperature of NOAA/NESDIS

  • Park, Kyung-Ae;Chung, Joug-Yul;Kim, Kuh;Choi, Byung-Ho
    • 대한원격탐사학회지
    • /
    • 제10권2호
    • /
    • pp.83-107
    • /
    • 1994
  • Sea surface temperatures (SSTs) estimated by using the operational SST derivation equations of NOAA/NESDIS were compared with satellite-tracked drifter temperatures. As a result of eliminating cloud-filled or contaminated pixels through several cloud tests, 69 matchup points between the drifter temperatures and the SSTs estimated with NOAA satellite 9, 10. 11 and 12 data from August, 1993 to July, 1994 were collected. Multi-channel sea surface temperature(MCSST) using a split window technique showed an approximately $1.0{\circ}C$ rms error as compared with the drifting buoy temperatures for 69 coincidences. Accuracies for satellete-derived sea surface temperatures were evaluated for only NOAA-11 AVHRR data which had relatively large matchups of 35points as compared with other satellites. For the comparison of the oberved temperatures with the calculated SSTs, linear MCSST and nonlinear cross product sea surface temperature(CPSST) algorithms by the split, the dual and the triple window technique were used respectively. As a result, the split window CPSSTs showed the smallest rms error of $0.72{\circ}C$. Defferences between the split window SSTs and the drifter temperatures appeared th have a linear tendency against the drifter temperatures and also against the differences between AVHRR channel 4 and 5 brighness temperatures. This indicates some possibilities that satelite-derived SSTs operationally calculated from the NOAA/NESDIS equation in the seas around Korea have been underestimated as compared with actural SSTs in case sea water temperature is relatively low or the atmosphere over the sea surface is very dry like in winter, while overstimated in case of high temperature or very moist atmospheric equations based on local sea measurements around Korea instead of global measurements should be derived.

열적외 영상과 Landsat 8 위성으로부터 관측된 지표면 온도 비교 (Comparison of Surface Temperatures between Thermal Infrared Image and Landsat 8 Satellite)

  • 조채윤;지준범;박문수;박성화;최영진
    • 한국대기환경학회지
    • /
    • 제32권1호
    • /
    • pp.46-56
    • /
    • 2016
  • In order to analyze the surface temperature in accordance with the surface material, surface temperatures between Thermal InfraRed Image (TIRI) and Landsat 8 satellite observed at the commercial area (Gwanghwamun) and residential area (Jungnang) are compared. The surface temperature from TIRI had applied atmospheric correction and compared with that from Landsat 8. The surface temperatures from Landsat 8 at Gwanghwamun and Jungnang are underestimated in comparison with that from TIRI. The difference of surface temperature between the two methods is greater in summer than in winter. When the analysis area was divided into detailed regions, depending on the material and the position of the surface, correlation of surface temperature between TIRI with Landsat 8 is as low as 0.29 (Gwanghwamun) and 0.18 (Jungnang), respectively. The results were caused from the resolution difference between the two methods. While the surface temperatures of each zone from Landsat 8 were observed almost constant, high-resolution TIRI observed relatively precise surface temperatures. When the each area was averaged as one space, correlation of surface temperature between TIRIs and Landsat 8 is more than 0.95. The spatially averaged surface temperature is higher at Jungnang, representing residential areas, than at Gwanghwamun, representing commercial areas. As a result, the observation of high resolution is required in order to observe the precise surface temperature. This is because it appears that the spatial distribution of the various surface temperature in the range of micro-scale according to the conditions of the ground surface.

한국의 지중온도를 이용한 기후변화연구 (Climate change in Korea inferred from subsurface temperatures)

  • 이영민;김형찬;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • 대한원격탐사학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

A Molecular Dynamics Study of the Interaction of Oxygen Molecules with a Water Droplet

  • Ambrosia, Matthew Stanley
    • 한국환경과학회지
    • /
    • 제27권10호
    • /
    • pp.901-906
    • /
    • 2018
  • Water and oxygen are two of the most essential molecules for many species on earth. Their unique properties have been studied in many areas of science. In this study, the interaction of water and oxygen molecules was observed at the nano-scale. Using molecular dynamics, a water droplet with 30,968 water molecules was simulated. Then, 501 oxygen molecules were introduced into the domain. A few oxygen molecules were attracted to the surface of the water droplet due to van der Waals forces, and some oxygen molecules actually entered the water droplet. These interactions were visualized and quantified at four temperatures ranging from 280 to 370 K. It was found that at high temperatures, there was a higher possibility of the oxygen molecules penetrating the water droplet than that at lower temperatures. However, at lower temperatures, oxygen molecules were more likely to be found interacting at the surface of the water droplet than at high temperatures.

순수 티타늄 주조체의 주형온도에 따른 용탕반응성 및 표면거칠기 (Metal-Mold Reaction and Surface Roughness Measurement of Pure Titanium Casting Specimens with Mold Temperatures)

  • 차성수;송영주;박수철
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.297-305
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the change of metal-mold reaction and surface roughness in titanium casting specimens for phosphate-silica alumina bonded investment with mold temperatures. Methods: The metal-phosphate silica alumina bonded mold interface reaction and surface roughness of titanium casting specimens according to mold temperatures were investigated. The Specimens were analysed by scanning electron microscopy and surface roughness tester. Results: The oxidation behavior indicated by the growth of oxide thickness. The titanium-oxide layer were consisted two layer of a porous external and a dense internal one. The reaction layer and surface roughness increased with increasing investment material temperature. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $200^{\circ}C$.

도시화에 따른 건조환경이 하절기 광주시 외부공간의 열환경에 미치는 영향에 대한 연구 (The Impacts of Built Environmental Features on the Land Surface Temperatures for the Heat Wave Seasons in Gwangju, South Korea)

  • 홍성운;양동우;오병철
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.67-82
    • /
    • 2019
  • This study aims to examine the impacts of built environmental features on the nocturnal and diurnal temperatures during the heat wave season in Gwangju, Korea. Built environmental measures are summarized at micro-scale level, such as 50 meters and 100 meters from temperature monitoring spots. Regressing the built environment on nocturnal and diurnal temperatures, we estimate how the artificial constructs contribute to temperature either day and night times. We found that impervious surface ratio is positively and negatively associated with nocturnal and diurnal temperatures, respectively. Buildings and structures tend to construct high thermal mass and absorb heat during day time and emit it for the night time. This property contributes to the nocturnal temperature model. On the other hand, urban areas with more vertical structure tend to block sun radiation more than rural, and it is more likely to find the negative relationship between impervious surface ratio and the diurnal temperatures.

다결정 실리콘 PV모듈의 하절기 표면온도 예측을 위한 알고리즘 검토 및 외부인자별 영향 평가 (Evaluation on Calculation Algorithms for Polycrystalline Silicon PV Module Surface Temperatures by Varying External Factors during the Summer Period)

  • 정동은;염규환;이찬욱;도성록
    • 대한건축학회논문집:구조계
    • /
    • 제35권8호
    • /
    • pp.177-184
    • /
    • 2019
  • Recently, electric power usages and peak loads from buildings are increasing due to higher outdoor air temperatures and/or abnormal climate during the summer period. As one of the eco-friendly measures, a renewable energy system has been received much attention. Particularly, interest on a photovoltaic (PV) system using solar energy has been rapidly increasing in a building sector due to its broad applicability. In using the PV system, one of important factors is the PV efficiency. The normal PV efficiency is determined based on the STC(Standard Test Condition) and the NOCT(Nominal Operating Cell Temperature) performance test. However, the actual PV efficiency is affected by the temperature change at the module surface. Especially, higher module temperatures generally reduce the PV efficiency, and it leads to less power generation from the PV system. Therefore, the analysis of the relation between the module temperature and PV efficiency is required to evaluate the PV performance during the summer period. This study investigates existing algorithms for calculating module surface temperatures and analyzes resultant errors with the algorithms by comparing the measured module temperatures.

온수온돌 난방시 바닥면의 중성온도 설정에 관한 연구 (Establishment of Optimum Floor Surface Temperature Floor in Ondol Heating System)

  • 공성훈
    • 한국주거학회논문집
    • /
    • 제6권2호
    • /
    • pp.51-55
    • /
    • 1995
  • This study presents a real neutral floor surface temperature in floor panel heating system(Ondol). The Ondol heating system can keep the constant temperature. However, the actual temperature when a person sits on a floor can be different from the surface temparature of a floor it self. The contents of this study are as follows : 1) measuring the spatial distributions of thermal conditions 2) the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3) estimating the neutral floor surface temperatures by measuring floor surface temperatures.

  • PDF