• 제목/요약/키워드: Surface Solar Radiation

검색결과 384건 처리시간 0.023초

도시화에 따른 건조환경이 하절기 광주시 외부공간의 열환경에 미치는 영향에 대한 연구 (The Impacts of Built Environmental Features on the Land Surface Temperatures for the Heat Wave Seasons in Gwangju, South Korea)

  • 홍성운;양동우;오병철
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.67-82
    • /
    • 2019
  • This study aims to examine the impacts of built environmental features on the nocturnal and diurnal temperatures during the heat wave season in Gwangju, Korea. Built environmental measures are summarized at micro-scale level, such as 50 meters and 100 meters from temperature monitoring spots. Regressing the built environment on nocturnal and diurnal temperatures, we estimate how the artificial constructs contribute to temperature either day and night times. We found that impervious surface ratio is positively and negatively associated with nocturnal and diurnal temperatures, respectively. Buildings and structures tend to construct high thermal mass and absorb heat during day time and emit it for the night time. This property contributes to the nocturnal temperature model. On the other hand, urban areas with more vertical structure tend to block sun radiation more than rural, and it is more likely to find the negative relationship between impervious surface ratio and the diurnal temperatures.

시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발 (The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation)

  • 엄재용;이충국;장월상;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

일사열 배제를 위한 통기벽체 적정 길이에 대한 검토 (A Study on the optimal length of air cavity for Solar heat removal with Air-Vent System)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.33-38
    • /
    • 2004
  • Outside wall systems we lost much energy from the dew of thermal bridge and unsuitable adiabatic construction. The air vent wall system can make reduce cooling loads from the outside wall in summer. The basic concept is connected with buoyant force by the difference of density. An external surface of a wall absorbs solar radiation, and transfers it to the air in the cavity. The warmed air gets buoyant force. So the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable. The purpose of this study is finding optimal length of air cavity by numerical analyses.

회전 반사판을 이용한 태양광발전장치의 발전량 향상 (Improvement of the Power Generation of Photovoltaic Generation System using Rotating Reflector)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권5호
    • /
    • pp.157-162
    • /
    • 2020
  • 기존의 태양광발전장치 중에서 반사판을 갖춘 장치는 태양에너지(일사량)를 태양광 모듈 표면에 집중적으로 입사되는 방식이지만 태양광 모듈을 통해 다시 반사되어 손실되는 태양에너지(일사량)는 고려되지 않는 구조로 되어있다. 또한, 태양광 모듈 주위에 반사판을 설치하여 발전량을 높이는 방안이 제시되고 있지만, 이는 다른 태양광 모듈의 음영에 따른 발전 저하에 영향을 주고 있다. 따라서 이러한 문제점을 개선하고자 본 논문에서는 1) 음영에 따른 태양광 모듈의 발전에 영향을 주지 않으면서 2) 태양광 모듈에서 반사되어 손실되는 태양에너지(일사량)를 회전하는 반사판을 이용하여 태양광 모듈에 다시 입사되는 방법을 연구 및 제안한다. 따라서 손실된 태양에너지(일사량)의 무수한 반사 각도에 따른 태양에너지를 재활용할 수 있는 방법을 통해 태양에너지(일사량)에 대한 손실을 최소화, 동일 일사량에 대한 발전량을 최대화하므로 태양광발전장치의 발전량을 증가시킬 수 있다.

서울시 대기중 오존오염도의 연도별 변화와 그 영향인자 분석: 광화문 지역을 중심으로 (Yearly Variation and Influencing Factors of Ozone Concentration in the Ambient Air of Seoul)

  • 이기원;권숙표;정용
    • 한국대기환경학회지
    • /
    • 제9권1호
    • /
    • pp.107-115
    • /
    • 1993
  • This study was carried out to find the characteristics of surface ozone concentration data obtained during 1988-1991 by the Korea Ministry of Environment. Seasonal data (spring, summer, autumn and winter) wre obtained in May, August, November and February respectively at Kwanghwamun in Seoul. The pollutants analyzed in this study are $SO_2, TSP, CO, NO, NO_2 and NO_2/NO$. Atmospheric factors such as solar radiation, wind speed, relative humidity, cloud amount and atmospheric temperature are also analyzed. The influence of pollutants and atmospheric factors that affect ozone concentration were analyzed by statistical method. The results are summarized as follows : 1. The ozone concentration varied seasonally. The maximum values were 23 ppb in spring, 33 ppb in summer, 16 ppb in autumn and 13 ppb in winter. So the seasonal ozone value was highest in Summer. 2. Te diurnal concentration of ozone was highest during 2-4 P. M. and was very low in the morning and evening. 3. The maximal correlation coefficients of each season between ozone concentration and the influencing pollutants or atmospheric factors asr as follows ; a. spring, r = 0.44(solar radiation) b. summer, r = -0.59(relative humidity) c. autumn, r = -0.55(relative humidity) d. winter, r = -0.58($NO_2$) 4. The major factor affecting the ozone concentration in spring was solar radiation, Relative humidity was the first affecting factor in summer, autumn and $NO_2$ concentration was dominant in winter.

  • PDF

경사진 산림지형에서의 자연유동에 대한 수치해석 (Numerical Simulation of the Flow Patterns with Sloping Forest Canopies)

  • 윤현기;;유기수;정명균
    • 대한기계학회논문집B
    • /
    • 제32권3호
    • /
    • pp.173-180
    • /
    • 2008
  • Diurnal variation of the flow over a forest canopy on a mountain slope is simulated numerically. In the daytime, the earth surface is heated by the solar radiation and the flow goes up the mountain due to the buoyancy force, and during the night, the air is drained downward along the slope owing to the cooling of the surface by radiation. In this flow process the forest canopy that consists of leaf region and the trunk region plays a dominant role as a momentum sink to the flow, thus the modeling of the leaf area region and trunk region is critical to the successful flow simulation. In the present study, a field measurement in an experimental forest in the State of Oregon in the United States is numerically analyzed. The resistance to the flow in the leaf region is directly related to the leaf area density (LAD), and the trunk is modeled as a cylinder.

2004년 7월 봇돌바다의 썰물, 전류 및 밀물시 수온과 염분 분포 (Distributions of temperature and salinity in relation to ebb, turn of tide and flood of the Bottol Bada in July, 2004)

  • 최용규;조은섭;이용화;이영식
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.167-175
    • /
    • 2005
  • Based on the observation on 20, 23 and 26 July 2004, the distributions of temperature, salinity and stratification was investigated in relation to ebb, turn of tide and flood. The results are as follows: I) The high temperature and low saline water with $23.5\~24.0^{\circ}C\;and\;32.4\~33.0psu$ existed at Naro Island. 2) The cold surface water below $21.0^{\circ}C\;and\;33.0\~33.4psu$ appeared in the area near Gae Island and Geumo Island. 3) The cold and saline water, below $24.0^{\circ}C$ at the surface and $17.0^{\circ}C$ near the bottom, $32.8\~33.8psu$ at the surface and $33.8\~34.0psu$ near the bottom, existed in Sori Island. These waters were more saline compared to the South Sea Coastal Water with about 31.8psu. This suggests that the oceanic saline water intruded into the Bottol Bada through the area near Sori Island. The stratification appeared during all the observation periods due to a high solar radiation of $22MJ/m^2$, and a weak wind speed of 2.9m/s on the average while the mean speed of wind in July is around 3.9 m/s. It qualitatively suggested that the stratification was maintained during the observation periods because of a high solar radiation, a weak wind speed and intrusion of saline oceanic water.

경기북부지역 정밀 수치기후도 제작 및 활용 - I. 수치기후도 제작 (Development and Use of Digital Climate Models in Northern Gyunggi Province - I. Derivation of DCMs from Historical Climate Data and Local Land Surface Features)

  • 김성기;박중수;이은섭;장정희;정유란;윤진일
    • 한국농림기상학회지
    • /
    • 제6권1호
    • /
    • pp.49-60
    • /
    • 2004
  • Northern Gyeonggi Province(NGP), consisting of 3 counties, is the northernmost region in South Korea adjacent to the de-militarized zone with North Korea. To supplement insufficient spatial coverage of official climate data and climate atlases based on those data, high-resolution digital climate models(DCM) were prepared to support weather- related activities of residents in NGP Monthly climate data from 51 synoptic stations across both North and South Korea were collected for 1981-2000. A digital elevation model(DEM) for this region with 30m cell spacing was used with the climate data for spatially interpolating daily maximum and minimum temperatures, solar irradiance, and precipitation based on relevant topoclimatological models. For daily minimum temperature, a spatial interpolation scheme accommodating the potential influences of cold air accumulation and the temperature inversion was used. For daily maximum temperature estimation, a spatial interpolation model loaded with the overheating index was used. Daily solar irradiances over sloping surfaces were estimated from nearby synoptic station data weighted by potential relative radiation, which is the hourly sum of relative solar intensity. Precipitation was assumed to increase with the difference between virtual terrain elevation and the DEM multiplied by an observed rate. Validations were carried out by installing an observation network specifically for making comparisons with the spatially estimated temperature pattern. Freezing risk in January was estimated for major fruit tree species based on the DCMs under the recurrence intervals of 10, 30, and 100 years, respectively. Frost risks at bud-burst and blossom of tree flowers were also estimated for the same resolution as the DCMs.

지붕형 태양광 발전량 산정을 위한 서울지역 그림자 효과 분석 (Analysis of Shadows Effect in Seoul Area for the Estimation of Roof-type PV Power Calculation)

  • 윤창열;정보린;김신영;김창기;김진영;김현구;강용혁;김용일
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.45-53
    • /
    • 2018
  • For the preliminary step for estimating the performance of roof-type photovoltaic system in urban areas, we analyzed the solar radiation reduction ratio by shadow effect by buildings using DSM (Digital Surface Model) and GIS (Geographical Information System) tools. An average loss by the shadow is about 19% in Seoul. The result was related to the building density and distribution. Monthly results show that the winter season (December and January) was more affected by the shading than during the summer season (June and July). It is expected that useful empirical formulas can be made if more detailed correlation studies are performed.

1994년 인천 연안역의 열수지 (Heat Budget in Incheon Coastal Area in 1994)

  • 최용규;윤홍주
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.293-297
    • /
    • 1999
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) in Incheon harbor of National Fisheries Research and Development Institute, heat budget in Incheon coastal area was estimated. The temperature differences between the sea surface and near bottom were nearly within 1$^{\circ}C$. This indicate the mixing from the sea surface and the bottom. The net heat flux through the sea surface and the advection through the inner and outer bay was affected uniformly to the water body in Incheon coastal area. The net heat flux was about 110W/$m^2$ in maximum value on May, about -80W/$m^2$ in minimum on January. The net heat flux through the sea surface from the solar radiation was about 2.35$\times$${10}^5$W during the year. This heat flux flew out the bay through the advection by the same flux.

  • PDF