• Title/Summary/Keyword: Surface Solar Radiation

Search Result 384, Processing Time 0.024 seconds

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

The Prediction of Temperature in Composite Box Girder Bridges (합성 박스형 교량의 온도 예측)

  • Chang, Sung Pil;Im, Chang Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.431-440
    • /
    • 1997
  • The paper describes a theoretical model for the prediction of bridge temperatures from meteorological data measured at bridge site and local meteorological center together with existing finite element heat transfer theory and solar radiation transfer theory to determine the time dependent temperature distribution of bridge. In this analytical model, the most adequate equation for the calculation of solar radiation on the bridge surface, which is dominant in day time is described based on the results of several experimental studies for the solar energy. The validity of this model is tested against field data obtained from long term experimental program on Sadang Viaduct in Seoul. Also, this paper describes the linear correlation between design variables and meteorological data to establish analytical criteria for the prediction of the average temperature, which are responsible for the longitudinal deformation of the bridges and of the vertical differential temperature profiles. which are responsible for the bending deformations from the long term experimental results.

  • PDF

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector (태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구)

  • Woo, Jong-Soo;Choi, Kwang-Hwan;Yoon, Jeong-In
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

Study on the Variation Characteristic of the Photo-Volatic Power Generation due to Regional Meteorological Elements (국지 기상 요소에 의한 태양광 발전량 변동특성에 관한 연구)

  • Lee, Soon-Hwan;Kim, Hae-Dong;Cho, Chang-Bum
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1943-1951
    • /
    • 2014
  • In order to clarify the characteristics of Photo-Volatic(PV) power generation over the Korean peninsula with complex terrain, special meteorological observation campaign was carried out for one year from 25 May 2011. Analysis is based on the comparison between observed meteorological elements and PV values generated at rated capacity 200 kW power plants. Solar radiation observed at $15^{\circ}$ inclined surface is 11 % larger than that observed at horizontal surface due to low elevation angel of the sun during winter season. The PV power generation tend to be more similar the variation of inclined surface irradiance than horizontal surface irradiance. Increasing air temperature often induce disturbance of the PV power generation. However, the higher the air temperature in winter season, the higher PV power generation because the PV module may be more activated at higher air temperature. PV generating efficiency tends to be conversed the value of 15%.

Combined Radiation and Natural Convection Heat Transfer in an Enclosure with a Constant Heat Flux at the Bottom (밑면에 균일 열유속이 존재하는 밀폐공간에서의 복사 - 자연대류열전달)

  • Kwon, Sun-Sok;Kwon, Yong-Il
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.28-42
    • /
    • 1992
  • This investigation is carried out numerically for the two dimensional natural convection and surface radiation heat transfer in a square enclosure. The bottom wall is a constant heat flux at hot temperature and also top wall is isothermal at cold temperature whereas the left and right side walls are adiabatic except a transparent window on the right side partially. The exchange of radiant energy is obtained by the net radiation method and the shape factor by the crossed string method. The change in temperature and Nusselt number distributions of the walls due to the effect of the wall emissivity for various emissivities and for various dimensionless insolation energies are investigated. The dimensionless local convective heat flux and local radiative heat flux distributions in the wall except an adiabatic wall are also compared.

  • PDF

Estimation of Surface Solar Radiation using Ground-based Remote Sensing Data on the Seoul Metropolitan Area (수도권지역의 지상기반 원격탐사자료를 이용한 지표면 태양에너지 산출)

  • Jee, Joon-Bum;Min, Jae-Sik;Lee, Hankyung;Chae, Jung-Hoon;Kim, Sangil
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.228-240
    • /
    • 2018
  • Solar energy is calculated using meteorological (14 station), ceilometer (2 station) and microwave radiometer (MWR, 7 station)) data observed from the Weather Information Service Engine (WISE) on the Seoul metropolitan area. The cloud optical thickness and the cloud fraction are calculated using the back-scattering coefficient (BSC) of the ceilometer and liquid water path of the MWR. The solar energy on the surface is calculated using solar radiation model with cloud fraction from the ceilometer and the MWR. The estimated solar energy is underestimated compared to observations both at Jungnang and Gwanghwamun stations. In linear regression analysis, the slope is less than 0.8 and the bias is negative which is less than $-20W/m^2$. The estimated solar energy using MWR is more improved (i.e., deterministic coefficient (average $R^2=0.8$) and Root Mean Square Error (average $RMSE=110W/m^2$)) than when using ceilometer. The monthly cloud fraction and solar energy calculated by ceilometer is greater than 0.09 and lower than $50W/m^2$ compared to MWR. While there is a difference depending on the locations, RMSE of estimated solar radiation is large over $50W/m^2$ in July and September compared to other months. As a result, the estimation of a daily accumulated solar radiation shows the highest correlation at Gwanghwamun ($R^2=0.80$, RMSE=2.87 MJ/day) station and the lowest correlation at Gooro ($R^2=0.63$, RMSE=4.77 MJ/day) station.

Light Trapping in Silicon Based Tandem Solar Cell: A Brief Review

  • Iftiquar, Sk Md;Park, Hyeongsik;Dao, Vinh Ai;Pham, Duy Phong;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Among the various types of solar cells, silicon based two terminal tandem solar cell is one of the most popular one. It is designed to split the absorption of incident AM1.5 solar radiation among two of its component cells, thereby widening the wavelength range of external quantum efficiency (EQE) spectra of the device, in comparison to that of a single junction solar cell. In order to improve the EQE spectra further and raise short circuit current density ($J_{sc}$) an optimization of the tradeoff between the top and bottom cell is needed. In an optimized cell structure, the $J_{sc}$ and hence efficiency of the device can further be enhanced with the help of light trapping scheme. This can be achieved by texturing front and back surface as well as a back reflector of the device. In this brief review we highlight the development of light trapping in the silicon based tandem solar cell.

Investigation of Anti-Reflection Coatings for Crystalline Si Solar Cells (결정질 실리콘 태양전지에 적용되는 반사방지막에 관한 연구)

  • Lee, Jae-Doo;Kim, Min-Jeong;Lee, Soo-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.367-370
    • /
    • 2009
  • It is important to reduce a reflection of light as a solar cell is device that directly converts the energy of solar radiation to electrical energy in oder to improve efficiency of solar cells. The antireflection coating has proven effective in providing substantial increase in solar cell efficiency. This paper investigates the formation of thin film PSi(porous silicon) layer on the surface of crystalline silicon substrates without other ARC(antirefiection coating) layers. On the other hand the formation of $SO_{2}/SiN_x$ ARC layers on the surface of crystalline silicon substrates. After that, the structure of PSi and $SO_2/SiN_x$ ARC was investigated by SEM and reflectance. The formation of PSi layer and $SO_{2}/SiN_x$ ARC layers on the textured silicon wafer result about 5% in the wavelength region from 0.4 to $1.0{\mu}m$. It is achieved on the textured crystalline silicon solar cell that each efficiency is 14.43%, 16.01%.

  • PDF

The Character of Distribution of Solar Radiation in Mongolia based on Meteorological Satellite Data (위성자료를 이용한 몽골의 일사량 분포 특성)

  • Jee, Joon-Bum;Jeon, Sang-Hee;Choi, Young-Jean;Lee, Seung-Woo;Park, Young-San;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.139-147
    • /
    • 2012
  • Mongolia's solar-meteorological resources map has been developed using satellite data and reanalysis data. Solar radiation was calculated using solar radiation model, in which the input data were satellite data from SRTM, TERA, AQUA, AURA and MTSAT-1R satellites and the reanalysis data from NCEP/NCAR. The calculated results are validated by the DSWRF (Downward Short-Wave Radiation Flux) from NCEP/NCAR reanalysis. Mongolia is composed of mountainous region in the western area and desert or semi-arid region in middle and southern parts of the country. South-central area comprises inside the continent with a clear day and less rainfall, and irradiation is higher than other regions on the same latitude. The western mountain region is reached a lot of solar energy due to high elevation but the area is covered with snow (high albedo) throughout the year. The snow cover is a cause of false detection from the cloud detection algorithm of satellite data. Eventually clearness index and solar radiation are underestimated. And southern region has high total precipitable water and aerosol optical depth, but high solar radiation reaches the surface as it is located on the relatively lower latitude. When calculated solar radiation is validated by DSWRF from NCEP/NCAR reanalysis, monthly mean solar radiation is 547.59 MJ which is approximately 2.89 MJ higher than DSWRF. The correlation coefficient between calculation and reanalysis data is 0.99 and the RMSE (Root Mean Square Error) is 6.17 MJ. It turned out to be highest correlation (r=0.94) in October, and lowest correlation (r=0.62) in March considering the error of cloud detection with melting and yellow sand.