• 제목/요약/키워드: Surface Properties Test

검색결과 1,822건 처리시간 0.032초

작업복 소재 직물의 액상 수분 전달 특성 및 표면특성 연구 (Liquid Moisture Management and Surface Properties of the Fabric in Transient Condition)

  • 유신정
    • 한국의류학회지
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2001
  • As important factors determining human sensorial comfort, liquid moisture management and surface properties of heat resistant workwear materials were examined. To figure out liquid moisture management properties of the test materials, absorption capacity, rate of absorption, and evaporation properties were assessed. A modified GATS(Gravimetric Absorbency Testing System) was used to measure the liquid moisture accumulation associated with the wicking of liquid moisture from sweating skin. The GATS procedure measures demand wettability of materials to take up liquid in a direction perpendicular to the fabric surface and it was modified to incorporate a special test cell and cover to assess absorption behavior in the presence of evaporation. Fabric stiffness, smoothness, number and the length of surface fibers, and an estimate of the contact area between the skin and fabric surface were measured to characterize the mechanical and surface properties of the test materials. Also an estimate of the force with which a fabric clings to moist skin was made using as wet-cling index.

  • PDF

녹차잎분말을 사용한 마루판의 특성 (Characteristics of Fancy Veneer Plywood Floor using Green Tea Leaves Powder)

  • 강석구;이화형
    • 한국가구학회지
    • /
    • 제21권4호
    • /
    • pp.284-292
    • /
    • 2010
  • This research was carried out to examine the properties of fancy cherry veneer overlaid on the PF resin bonded Meranti plywood floor, which 2.5% green tea leaf powder was applied in the UV varnishes and the adhesives for scavenging the volatile organic compounds. The results were as follows: 1. The various properties of the treated samples, such as density, moisture content, thickness swelling, bending strength(MOR), adhesion shear strength, surface abrasion, curling, cyclic delamination test with boiling water, boiling property, cold-resistance and heat resistance, acid resistance and alkali resistance, and anti-contamination property showed no significant difference between the properties of the control samples. 2.5% green tea leaf powder treated floor gave a little better results than the control for surface scratch test. 2. In case of QUV and weathering test, no difference between the treated sample and control was found. 3. The floor was discolored by adding 10% green tea leaf powder to UV coating, and the floor was also discolored to light green during by the soaking test. The color of floor was not changed up to 5% addition level.

  • PDF

Silicon rubber 애자의 salt-fog 표면열화 특성 (Surface Aging Properties of Silicon Rubber Insulator by salt-fog)

  • 이종찬;이운용;조한구;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF

Investigation on Adhesion Properties of Sandwich Composite Structures Considering on Surface Treatments

  • Park, Gwanglim;Oh, Kyungwon;Kong, Changduk;Park, Hyunbum
    • International Journal of Aerospace System Engineering
    • /
    • 제1권1호
    • /
    • pp.16-20
    • /
    • 2014
  • Recently, various kinds of study on light weight structure are performing in the world. The Al honeycomb sandwich structural type adopt for improvement of lightness and structural stability to major part structure of aircraft or spacecraft. Adhesion badness properties of adhesive and adhesion properties of fillet mainly studied about al honeycomb structure. But study for adhesive properties of sandwich construction with surface treatment of Aluminum alloy barely performed. In this study, adhesive film was used between Al and honeycomb core of honeycomb panel[1]. The study for adhesive properties of sandwich construction with surface treatment of AA 5052 skin was performed.

액상확산접합한 Ni기 단결정 초내열합금의 크리프 파단 및 피로특성 (Creep-Rupture and Fatigue Properties of Transient Liquid Phase Bonded Joints of Ni-Base Single Crystal Superalloy)

  • 김대업
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.82-87
    • /
    • 2001
  • The creep-rupture and low cycle fatigue properties of transient liquid phase bonded joints of Ni-base single crystal superalloy, CMSX-2 was investigated using MBF-80 insert metal. The (100) orientation of bonded specimen was aligned perpendicular to the joint interface. CMSX-2 was bonded at 1523K for 1.8ks in vacuum, optimum bonding condition. The creep rupture strength and rupture lives of the joints were the almost identical to ones of the base metal. SEM observation of the fracture surfaces of joints after creep rupture test revealed that the fracture surfaces classified three types of region, ductile fracture surface, cleavage fracture surface and interfacial fracture surface. The low cycle fatigue properties of the joints were also the same level as those of base metal. The elongation and reduction of area values of joints were comparable to those of base metal while fell down on creep rupture condition of high temperature.

  • PDF

도포공법에 의한 콘크리트 구조물의 내구성 증진에 관한 실험적 연구 (An Experimental study on durability improvement of concrete structures by a concrete coating method)

  • 조병완;문린곤;박승국;김대민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.721-726
    • /
    • 2003
  • The Durability of Concrete Structure is serverely degraded due to mainly carbonation, sulfate attack and chloride ion diffusion in concrete. The ultimate purpose of this study is to obtain how much the durability of Concrete Structure is improved according to the variation of physical properties in concrete or the frequency of surface coating on concrete. Where, variation of physical properties is a water-cement ratio or amount of air. The experiments are the chliride ion diffusion test, the lapid corrosion test, the lapid carbonation test, the test on resistance to freezing and thawing. Finally, this study shows that the effect by the surface coating method is better than the variation of physical properties in concrete.

  • PDF

Silicon rubber 애자의 salt-fog 표면열화 특성 (Surface Aging Properties of Silicon Rubber Insulator by salt-fog)

  • 이종찬;이운용;조한구;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively. Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF

온돌용 목질마루판의 표면물성 (Surface Properties of Wood-Based Floorings for Under Heating Systems (Ondol))

  • 김종인;박종영;이병후;김현중
    • 한국가구학회지
    • /
    • 제13권1호
    • /
    • pp.27-37
    • /
    • 2002
  • This study was investigated with the surface properties such as physical and accelerated tests of wood-based floorings. In physical test, hardness and abrasion resistance values of laminate floorings were higher than those of others. The center line average surface roughness($R_a$) of imported laminate flooring was highest value($1.34{\mu}m$) and that of imported solid wood flooring was lowest value($0.62{\mu}m$). In cold resistance and moist heat resistance, no defects were found on the surface of all flooring (crack, blistering, peeling, and gloss loss etc.) after testing. Wet-cold-dry cycle test showed that plywood flooring appeared some cracks. In accelerated weathering test, color difference increased with increasing Xenon arc light irradiation

  • PDF

Performance of a Surface Densified P/M Gear for a Passenger Car Gear Box

  • Rau, Gunter;Sigl, Lorenz S.;Mork, Gerold;Wattenberg, Frank
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.389-390
    • /
    • 2006
  • Selective surface densification is a tool for improving the mechanical properties of PM steels, such that the requirements for highly loaded gears can be matched. This paper describes the manufacturing and the properties of a helical P/M gear. The gear performance was evaluated on a 3-shaft back to back test rig, on a load bearing test rig and on a sound test bench. The results of these tests are presented and compared to data obtained from solid steel gear with identical geometry and surface quality. This comparison indicates that P/M gears have a load bearing capacity and noise level which are both well comparable to solid steel gears.

  • PDF

Effect of Fiber Hybridization on Durability Related Properties of Ultra-High Performance Concrete

  • Smarzewski, Piotr;Barnat-Hunek, Danuta
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.315-325
    • /
    • 2017
  • The purpose of the paper is to determine the influence of two widely used steel fibers and polypropylene fibers on the sulphate crystallization resistance, freeze-thaw resistance and surface wettability of ultra-high performance concrete (UHPC). Tests were carried out on cubes and cylinders of plain UHPC and fiber reinforced UHPC with varying contents ranging from 0.25 to 1% steel fibers and/or polypropylene fibers. Extensive data from the salt resistance test, frost resistance test, dynamic modulus of elasticity test before and after freezing-thawing, as well as the contact angle test were recorded and analyzed. Fiber hybridization relatively increased the resistance to salt crystallization and freeze-thaw resistance of UHPC in comparison with a single type of fiber in UHPC at the same fiber volume fraction. The experimental results indicate that hybrid fibers can significantly improve the adhesion properties and reduce the wettability of the UHPC surface.