• Title/Summary/Keyword: Surface Interval

Search Result 588, Processing Time 0.027 seconds

Effect of mixtures of gibberellic acid and several herbicides on the herbicidal activity against wild oat (Avena fatua L.) (Gibberellic acid와 여러 가지 제초제와의 혼합처리가 메귀리에 대한 제초활성에 미치는 영향)

  • Kim, Jin-Seog;Choi, Jung-Sup;Hong, Kyung-Sik;Cho, Kwang-Yun
    • The Korean Journal of Pesticide Science
    • /
    • v.2 no.3
    • /
    • pp.107-116
    • /
    • 1998
  • Based on the differential growth response to exogenous gibberellic acid ($GA_{3}$) between semi-dwarf wheat(Triticum aestivum) and wild oat(Avena fatua), we examined the possibility of improving the selective performance of several herbicides by $GA_{3}$ application and the physiological background of $GA_{3}$-induced increase in herbicidal activity. Growth of wild oat was 4 to 5 times higher than that of wheat by $GA_{3}$ treatment. Pretreatment of wild oat seed with 300 ppm $GA_{3}$ increased the herbicidal activities of trifluralin and isoproturon by soil-surface application, but not of alachor and metsulfuron-methyl. $GA_{3}$ applied simultaneously with post-emergence herbicides resulted in a significant or moderate improvement of the efficacy of such herbicides as tralkoxydim, fenoxaprop-ethyl, metsulfuron-methyl, metribuzine and isoproturon, but not in the mixtures of oxyfluorfen or paraquat with $GA_{3}$. In the sequencial treatment of tralkoxydim and $GA_{3}$ at interval of one-day, $GA_{3}$ applied prior to tralkoxydim significantly increased a chlorosis and desiccation of leaf without affecting the growth inhibition by tralkoxydim. Tralkoxydim followed by $GA_{3}$ application had lower herbicidal activity than that of $GA_{3}$ followed by tralkoxydim treatment. Electrolyte leakage response of $GA_{3}$-pretreated or $GA_{3}$-untreated wild oat leaf against several compounds inducing membrane. peroxidation was compared. Differencial responses were observed in oxyfluorfen and isoproturon treatments with an increased electrolyte leakage in $GA_{3}$-pretreated tissue, but not in paraquat and rose bengal treatments. These results suggest that $GA_{3}$-induced increase in herbicidal activity is likely to be dependent on a herbicide type and may be due to activation of a metabolic ability related with herbicidal reponse as well as an increase in the herbicide absorbtion and translocation, rather than due to membrane and cell wall extention induced by $GA_{3}$, which in turn makes the herbicides easily enter.

  • PDF

Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer (성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가)

  • Kim, Woo Chul;Min, Chul Kee;Lee, Suk;Choi, Sang Hyoun;Cho, Kwang Hwan;Jung, Jae Hong;Kim, Eun Seog;Yeo, Seung-Gu;Kwon, Soo-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.

Status and Change in Chemical Properties of Polytunnel Soil in Korea from 2000 to 2012

  • Kang, Seong Soo;Roh, Ahn Sung;Choi, Seung Chul;Kim, Young Sang;Kim, Hyun Ju;Choi, Moon Tae;Ahn, Byoung Gu;Kim, Hee Kwon;Park, Sang Jo;Lee, Young Han;Yang, Sang Ho;Ryu, Jong Soo;Sohn, Yeon Gyu;Kim, Myeong Sook;Kong, Myung Suk;Lee, Chang Hoon;Lee, Deog Bae;Kim, Yoo Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.641-646
    • /
    • 2013
  • Chemical properties of agricultural soils in Korea have been investigated at four-year interval in order of paddy, polytunnel, upland, and orchard soils since 1999; polytunnel soils were investigated over the whole country in 2000, 2004, 2008, and 2012. Polytunnel soils were taken from the surface (0-15 cm) and subsurface (15-30 cm) at 2,651, 1,274, 1,374 and 1,374 sites in all provinces of South Korea. One hundred sampling sites located in more than 400 m altitude were additionally investigated in 2008 and 2012. Average of soil chemical properties in 2012 except Jeju province were 6.6 for pH, 3.2 dS $m^{-1}$ for EC, 37 g $kg^{-1}$ for organic matter (OM), 1,049 mg $kg^{-1}$ for available (Avail.) phosphate, 1.58 $cmol_c\;kg^{-1}$ for exchangeable (Exch.) K, 10.6 $cmol_c\;kg^{-1}$ for Exch. Ca, and 3.3 $cmol_c\;kg^{-1}$ for Exch. Mg. Except pH, averages of all chemical properties exceeded the upper limit of optimal range. The median values except pH showed a lower value than the averages. The pH, OM and Exch. Ca had slightly increased from 6.3 to 6.6, from 34 to 37 g $kg^{-1}$, and from 7.7 in 2000 to 10.6 $cmol_c\;kg^{-1}$ in 2012, respectively. The order of sample ratios exceeding the optimal range were Avail. $P_2O_5$ (83%) > Exch. Ca (80%) > Exch. K (70%) > Exch. Mg (65%) > EC (55%) > OM (48%) > pH (29%) in 2012. The order of sample ratios below the optimal range was OM (25%) > Exch. K (25%) > pH (20%), Exch. Mg and Avail. $P_2O_5$ (9%) > Exch. Ca (6%) in 2012. The excessive proportion of pH, Exch. Ca, Exch. Mg and OM slightly increased, while the insufficient proportion of those decreased. Approximately 55% of polytunnel soils exceeding EC 2 dS $m^{-1}$ was evaluated with salt accumulated soils having the risk of growth disorder of crops. Nutrient contents in polytunnel soils in Korea showed high level especially Avail. $P_2O_5$ and Exch. cations. Therefore, recommended fertilization based on soil testing or plant testing is needed for soil nutrient management.

A Study on Soil Characteristics of Poorly Vegetation Space for Landscape Remodeling Planning on Apartment Complex (아파트 조경 식생불량공간 리모델링 설계를 위한 토양특성 연구)

  • Han, Seung-Won;Kim, Kwang Jin;Yun, Ji Hye;Jeong, Na Ra;You, Soo Jin
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.1
    • /
    • pp.85-92
    • /
    • 2020
  • The purpose of this study is to provide base information that can be utilized in surveying the status of landscape management within apartment complexes and grasping the conditions of the soil for planting plants, as a way to improve the quality of green spaces by repairing poorly vegetated spaces within apartment complexes and remodeling them with diverse species of plants. Considering that trees and shrubs of equal sizes are simultaneously planted upon the completion of apartment complexes, they were divided based on their completion year at the interval of 5 years and differences in the growth of trees and the components of soil over time were analyzed. Out of the species of trees planted in all the 9 apartment complexes surveyed in this study, the growth of 4 species of needleleaf trees and 4 species of broadleaf trees were surveyed. Juniperus chinensis 'Kaizuka' and Pinus densiflora Siebold & Zucc. out of the needleleaf trees and Malus floribunda Siebold ex Van Houtte out of the broadleaf trees showed the highest growth rate when over 5 years passed after planting and their growth rate decreased when over 10 years passed. Platycladus orientalis and Acer palmatum Thunb. in the apartment complexes that were built over 10 years ago showed the highest growth rate, which indicates that the species require a relatively long period of time for growth. The hardness of the soil at the areas where trees were planted but their soil surface was bare was analyzed. When over 5 years passed after the completion of apartment complexes, over 20 mm of the soil was found to be stamped. The physicochemical properties of soil were also surveyed and the pH level was found to have been continuously high ever since the completion. The organic content in the surveyed soil was about 1/3 of the content in fertile soil, which means that additional fertilization is required. These results indicate that the stamped soil and the health of soil can be restored, when replanting plants in bare areas, by adding plans to improve soil, such as designing drain ways around the planted areas, transporting soil for the 50 cm depth of the ground and mixing organic matters such as chaff, and simply by planting groundcover plants in the lower part of tress and shrubs.

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.

Spatial Distribution of Rice Root under Long-term Chemical and Manure Fertilization in Paddy (화학비료 및 희비 장기시용에 따른 벼 뿌리 분포 특성)

  • 전원태;박창영;조영손;박기도;윤을수;강위금;박성태;최진용
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.6
    • /
    • pp.484-489
    • /
    • 2003
  • It is well known that root distribution of rice is a crucial factor for nutrient absorbtion and affect by soil fertility management. However, the findings on root distribution are limited due to laborious and tedious work. The characteristics of root distribution were investigated in long-term fertilizer experiment plots that were established in paddy soil, a fine silty family of typic Hal-paqueps (Pyeongtaeg series) in 1967. fertilizer experiment plots of no fertilizer, compost, NPK and NPK+compost plot have been maintained consistently for the past thirty six year and Npk+silicate plot for the past twenty two years. In NPK plot, 150kg N (urea), 100kg -$\textrm{P}_2\textrm{O}_5$ (fused phosphate) and 100kg $\textrm{K}_2\textrm{O}$(potassium chloride) per hectare have been applied. For NPK+silicate plot, 500kg $\textrm{Si}\textrm{O}_2$ (silicate) was applied in addition to fertilizer in NPK plot. For the compost plot, 10,000kg rice straw compost per hectare were applied. Root samples were taken from the positions of hill-center (below hill) and mid-point of four adjacent rice hills at heading stage by cylinder monolith (CM) method. The soil cores were sampled 20cm depth from the soil surface and partitioned four into layers at an interval of 5cm. The soil particles surrounding roots were washed out with tap water, Length and weight of the roots in each soil layer were measured and root length density (RLD), root weight density (RWD), specific root length(SRL) and rooting depth index (RDI) were calculated. Total root length was measured by intersection method. Plant height, tiller and shoot dry weight were the highest in NPK+compost plot. But RLD of hill-center soil cores was the highest in no-fertilizer plots. In the soil cores from mid-point position of four adjacent hills, RLD at 15-20cm soil depth was higher in compost plot than NPK plot. RLD in compost plots showed even distribution compared to those in chemical- fertilizer plots. RWD was the highest in the NPK+compost plot. SRL was the lowest in the NPK+silicate plot. RDI was the highest in the compost plot. Also, in this experiment it was found that the distribution of roots was closely related to the physical properties of the soil as affected by fertilization management.

Lung Preservation Study for Above 20 Hours of LPDG Solution in Canine Lung Allotransplactation (폐이식 실험견에서 LPDG용액을 이용한 20시간 이상 폐보존효과 관찰)

  • Park, Chang-Gwon;Gwon, Geon-Yeong;Yu, Yeong-Seon
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.949-960
    • /
    • 1997
  • Background. Limited ischemic tolerance of the lung has remained one of the factors that limits the expansion of pulmonary transplantation as a treatment for end-stage pulmonary disease. Numerous studies on safe long term preservation for lung transplantation has been performed for the purpose of developing ideal preservation solution with extracellular type or intracellular type solutions. In this. study, we examined the efficacy of L DG solution in lung preservation longer than 20 hours by comparison with modified Euro-Collins solution. Iwethods. Thirty-(our adult mongrel dogs were divided into two groups. Donor lungs were flushed with LPDG solution(n=9) or modified Euro-Collins(MEC) solution(n=8) and stored for 24 hours at 1$0^{\circ}C$. All donor lungs were perfused through the pulmonary arteries with solutions containing prostaglandin El and verapamil. Left canine lung allotransplantations wereperformed. Assessment(hemodynamic indices and arterial blood gas analysis) of left implanted lung was made by occluding the right pulmonary artery for ten minutes using pulmonary artery Cuff. Assessment was repeated at the interval of 30 minutes, one hour, and two hours later after reperfusion and then chest X-ray, computed tomogram and lung perfusion scan were obtained. In survival dogs follow-up studies were done with assessment with chest X-ray, computed tomogram of the chest and lung perfusion scan on 7th day postoperatively. After preservation above 20 hours, pathological examinations for ultrastructural findings on right lung were performed in each group. Results. With respect to arterial oxygen tension, LPDG group was superior to MEC but there was no statistical significance for 2 hours after reperfusion. Mean pulmonary artery pressure was less increased(p < 0.05) and cardiac output higher(p <0.05) than MEC group until 2 hours after reperfusion. After 2 hours of reperfusion, both groups showed transplanted lung function deteriorated gradually. Perfusion scan of the transplanted lung in LPDG group showed better perfusion rate in immediate post-reperfusion, 3 days and 7 days later respectively but there was no statistical significance and corelation with PaO2 and computed tomoRravhic views. In scanning electron microscopy of pulmonary artery after preservation, LPDG group relatively shows less irregular protrusion of the inner surface of endothelial cell of poulmonary artery than MEC group. Conclusions, e concluded that LPDG solution can offer safe lung preservation above 20 hours with adequate immunosuppressive therapy and prevention of the infection.

  • PDF

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.