• Title/Summary/Keyword: Surface Heat Flux

Search Result 757, Processing Time 0.03 seconds

A Study on the Analysis of Surface Heat Flux Using the Transient Heat Flux Method (비정상열유속 기법을 이용한 표면 열유속 해석에 관한 연구)

  • Yi, Jong-Ju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.503-510
    • /
    • 2010
  • The quick variation of the canister wall temperature causes the modification of the shape of canister wall. This paper is the possibility of adoption and the error analysis about the transient heat flux method. The commercial code(Fluent Ver6.2.16) was employed for the calculation of surface temperature in the case of steady and unsteady heat flux condition. Based the surface temperature variation and surface material property, transient heat flux method can calculate the surface heat flux. In the case of steady heat flux condition, the error is about 2%, and in the case of unsteady heat flux condition, the error is about 3.6%. With the unsteady heat flux condition, the time which reach the maximum surface heat flux is almost same between the numerical analysis and transient heat flux method.

Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994 (제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우-)

  • 김해동;양성기
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

A Study on the Spray Cooling Characteristics of hot Flat Plates (고온평판의 분무냉각특성에 관한 연구)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF

Surface Heat Flux and Oceanic Heat Advection in Sendai Bay

  • Yang Chan-Su;Hanawa Kimio
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.1
    • /
    • pp.11-24
    • /
    • 2006
  • Coastal sea surface temperature (CSST) and meteorological data from January through December 1995 are used to estimate the net surface heat flux and heat content for Sendai Bay. The average annual surface heat flux in the area north of the bay is estimated to be $+35Wm^{-2}$, whereas the southwestern area is estimated to be $+56Wm^{-2}$. Therefore, the net surface heat flux shows a net gain of heat over the whole bay. The largest heat gain occurs near Matsukawaura, where the strong Kuroshio/Oyashio interaction produces anomalously cold SST and wind is more moderate than in other regions of Sendai Bay over most of the year. The lowest heat gain occurs around Tashiro Island, where the temperature difference between air and sea surface is lower and wind is stronger. The heat budget shows that both surface forcing and horizontal advection are potentially important contributors to the seasonal evolution of CSST in the bay. From the A VHRR and SeaWiFS data, it is found that offshore conditions between the bay and Eno Island are different due to the presence of the Ojika Peninsula. It is also shown that the temporal behaviors of SSTs in the bay are closely connected with the air-sea heat flux and offshore conditions.

Heat Budget in Incheon Coastal Area in 1994 (1994년 인천 연안역의 열수지)

  • 최용규;윤홍주
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.293-297
    • /
    • 1999
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) in Incheon harbor of National Fisheries Research and Development Institute, heat budget in Incheon coastal area was estimated. The temperature differences between the sea surface and near bottom were nearly within 1$^{\circ}C$. This indicate the mixing from the sea surface and the bottom. The net heat flux through the sea surface and the advection through the inner and outer bay was affected uniformly to the water body in Incheon coastal area. The net heat flux was about 110W/$m^2$ in maximum value on May, about -80W/$m^2$ in minimum on January. The net heat flux through the sea surface from the solar radiation was about 2.35$\times$${10}^5$W during the year. This heat flux flew out the bay through the advection by the same flux.

  • PDF

Heat Transfer Characteristics of Spray Cooling Up to Critical Heat Flux on Thermoexcel-E Enhanced Surface (Thermoexcel-E 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성)

  • Lee, Yohan;Hong, Gwang-Wook;Lee, Jun-Soo;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.373-380
    • /
    • 2016
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) are measured on a smooth square flat copper heater of $9.53{\times}9.53mm$ at $36^{\circ}C$ in a pool, a smooth flat surface and Thermoexcel-E surfaces are used to see the change in HTCs and CHFs according to the surface characteristics and FC-72 is used as the working fluid. FC-72 fluid has a significant influence on heat transfer characteristics of the spray over the cooling surface. HTCs are taken from $10kW/m^2$ to critical heat flux for all surfaces. Test results with Thermoexcel-E showed that CHFs of all enhanced surface is greatly improved. It can be said that surface form affects heat transfer coefficient and critical heat flux.

Heat Transfer Characteristics of Spray Cooling up to Critical Heat Flux on a Low-fin Enhanced Surface (Low-fin 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성)

  • Lee, Yohan;Kang, Dong-Gyu;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.522-528
    • /
    • 2013
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) were measured on a smooth square flat copper heater of $9.53{\times}9.53$ mm at $36^{\circ}C$ in a pool, with a smooth flat surface, and 26 fpi. Low-fin surfaces were used to see the change in HTCs and CHFs according to the surface characteristics, and FC-72 was used as the working fluid. FC-72 fluid had a significant influence on the heat transfer characteristics of the spray over the cooling surface. HTCs were taken from 10 $kW/m^2$ to critical heat flux, for all surfaces. Test results with Low-fin showed that the CHFs of all the enhanced surface were greatly improved. It can be said that the surface form affects the heat transfer coefficient and critical heat flux.

Comparative Analysis of Surface Heat Fluxes in the East Asian Marginal Seas and Its Acquired Combination Data

  • Sim, Jung-Eun;Shin, Hong-Ryeol;Hirose, Naoki
    • Journal of the Korean earth science society
    • /
    • v.39 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Eight different data sets are examined in order to gain insight into the surface heat flux traits of the East Asian marginal seas. In the case of solar radiation of the East Sea (Japan Sea), Coordinated Ocean-ice Reference Experiments ver. 2 (CORE2) and the Objectively Analyzed Air-Sea Fluxes (OAFlux) are similar to the observed data at meteorological stations. A combination is sought by averaging these as well as the Climate Forecast System Reanalysis (CFSR) and the National Centers for Environmental Prediction (NCEP)-1 data to acquire more accurate surface heat flux for the East Asian marginal seas. According to the Combination Data, the annual averages of net heat flux of the East Sea, Yellow Sea, and East China Sea are -61.84, -22.42, and $-97.54Wm^{-2}$, respectively. The Kuroshio area to the south of Japan and the southern East Sea were found to have the largest upward annual mean net heat flux during winter, at -460- -300 and at $-370--300Wm^{-2}$, respectively. The long-term fluctuation (1984-2004) of the net heat flux shows a trend of increasing transport of heat from the ocean into the atmosphere throughout the study area.

A Calculation Method on Heat Flux from Ondol Floor Surface (온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究))

  • Sohn, Jang Yeul;Ahn, Byung Wook;Pang, Seung Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

Turbulence of the Coastal Atmospheric Surface Layer and Structure of the Coastal Atmospheric Boundary Layer (해안 대기 표층의 난류와 해안 대기 경계층의 구조)

  • Kwon, Byung-Hyuk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.3
    • /
    • pp.404-412
    • /
    • 2005
  • The surface energy budget depends on many factors, such as the type of surface, the soil moisture and the vegetation canopy, the geographical location, daily, monthly and seasonal variations, and weather conditions. In the coastal region, the surface is not homogeneous at various scales for instance water, sand, mud, tall grass, and crops. The energy balance over the vegetation canopy was analyzed with the optical energy balance measuring system. The latent heat flux was more intensive than the sensible heat flux. The sensible heat flux was very small in summer due to the canopy effect and higher in spring and autumn. In summer the development of the atmospheric boundary depended on rather the vertical shear of wind than the sensible heat flux.