• 제목/요약/키워드: Surface Contamination Level

검색결과 161건 처리시간 0.027초

미생물 간이 검사법 실시에 따른 학교급식소의 위생 및 건강관리 개선 효과 (Effects of Microbe Inspections in School Food Service Systems)

  • 한명숙;윤성태;임준;임정수
    • 보건교육건강증진학회지
    • /
    • 제23권3호
    • /
    • pp.53-63
    • /
    • 2006
  • Objectives: The purpose of this study was to analyze the effects of microbe inspections on the hygienic improvement of school food service systems. Methods: Thirty-three school food service systems in Incheon metropolitan city participated in the study from Sep. 2004 to Apr. 2005. Major items of microbe inspections were cutting boards, knives, kitchen towels, and kitchen staff's hands. The Rodac plate and hand plate were used to measure the surface contamination level of germs such as Staphylococcus aureus, Vibrio species, Salmonella species and E. coli. Results: This study compared the results of the inspections in Sep. 2004 and Apr. 2005. The surface contamination level of Staphylococcus aureus and Vibrio species on the knives and kitchen towels had significantly improved. However, the surface contamination level of E. coli on the hands of the kitchen staff had worsened. Conclusions: This study showed that microbe inspections could control the hygienic level of the school food service systems. In the future, microbe inspections should be actively used to improve sanitary conditions in the school lunch system.

ESS 안전성 개선을 위한 결로 운전 조건 고려 고체절연물 연면 절연파괴특성 분석 (Analysis on Solid Insulator Flashover Characteristics on Moisture Contamination for Electrical Insulation Improvement of ESS)

  • 김진태;이승용;김지영;석복렬
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.317-321
    • /
    • 2021
  • As the large-scale renewable energy power plant increases, the high-capacity and compact Energy Storage System (ESS) is required. However, this trend could reduce the insulation reliability of ESS. In this study, the surface flashover characteristics for four types of solid insulators are investigated in the uniform electric field with AC and Lightning Impulse (LI) voltage waveforms under various contamination levels. In addtion, insulator surfaces are compared based on the contact angle before and after surface flashover. The experimental results show that AC flashover voltage is dependent on the materials and the contamination level, but LI flashover voltage is only associated with the contamination level. Especially, AC flashover voltage of PC (PolyCarbonate) is higher than that of other insulators, which is associated with the unique and sequential creepage discharge propagation pattern of PC. The localized discharges on the surface of PC form corresponding tracking points. Then, the interconnected trackings result in the complete flashover. This flashover patterns degrade the surface of PC much more than that of epoxy and Bulk Molding Compoud (BMC). Thus, the contact angle of PC is significantly reduced compared to that of other insulators. The increased hydrophilicity in the surface of PC enhances the insulator surface conductivity.

치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사 (Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics)

  • 김설희
    • 치위생과학회지
    • /
    • 제17권6호
    • /
    • pp.472-480
    • /
    • 2017
  • 치과의료기관 의료장비 표면 및 치과위생사 손의 S. epidermidis 오염도 조사를 위해 2017년 7월부터 8월까지 일부지역 20개 치과의원에서 치과위생사 20인의 손 오염, 치과별 7부위 표면 140부위의 S. epidermidis 오염도를 조사하였다. S. epidermidis 오염도는 핸드플레이트와 로닥플레이트를 사용하였으며, $35^{\circ}C$ 24시간 배양하였다. 손 오염도는 핸드플레이트 기준에 근거하여 저, 중, 고 그룹으로 분류한 후 그룹별 손 부위별 오염도를 ANOVA 분석하였다. 의료장비 표면 오염수준은 집락을 계수하여 기술통계 하였다. 치과위생사 55%는 중등도 이상의 손 오염이 있었고, 부위별로는 손바닥이 29.45 CFU로 가장 높게 나타났으며, 그 다음으로는 중지 7.8 CFU, 약지 6.4 CFU, 엄지 6 CFU 순서였다. 의료장비 표면 오염도 조사결과 3-way 손잡이 4.45 CFU, 컴퓨터 마우스 3.37 CFU, 거울 손잡이 1.60 CFU로 다른 영역보다 높게 조사되었다. 손 오염도가 높은 집단일수록 손의 S. epidermidis 오염도가 높은 양적 상관관계를 나타내었다. S. epidermidis 오염도는 의료장비 표면 오염보다 손에서 높게 나타났다. 그러므로 의료진들은 손 위생의 중요성을 인식하고 WHO에서 제시한 방법으로 손 위생을 실천하는 것이 요구되었다. 의료진들이 감염관리 업무수행에 책임감을 갖고 안전한 의료 환경을 조성할 수 있도록 감염관리 지침과 체계적인 감염관리 업무 수행에 관한 교육이 요구되었다.

병원 화장실의 방사성 오염에 관한 연구 (A Study of Radioactive Contamination in Hospital Toilet)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

간호대학생의 실습 전후 실습복 오염도 및 비강내 황색포도알균 집락정도 비교 (A Comparison between the Contamination Level of Uniforms and the Nasal Staphylococcus aureus Colonization before and after the Clinical Practice of Nursing Students)

  • 박진희;신기수;김지영
    • Journal of Korean Biological Nursing Science
    • /
    • 제16권2호
    • /
    • pp.90-97
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the contamination level of uniforms with nasal colonization of Staphylococcus aureus before and after the clinical practice of nursing students. Methods: This study was a survey research, conducting microbial culture by smearing the front surface and the pockets of uniforms, and the nasal cavity both before and after clinical practice on 70 nursing students. For the analysis, descriptive statistics, chi-square test, paired t-test were used for statistical analysis using SPSS 19.0. Results: The contamination level of uniforms increased more significantly after clinical practice on the front surface (p=.008) and pockets (p=.031) than before clinical practice, and Staphylococcus aureus, and Enterobacter aerogenes were detected. Conclusion: Through the results above, it is believed that it is reasonable to do the laundering of clinical uniforms of nursing students once a week. Because it is possible to disseminate disease germs with the contamination of clinical practice uniforms in a hospital environment, it is necessary to offer education for the laundering of uniforms with appropriate management.

저속 2행정 박용 기관에서의 LO 입자 오염도에 따른 베어링 마모 특성 평가 (Evaluation of The Wear Characteristics on The White Metal Bearing in a Low Speed Two-Stroke Marine Diesel Engine)

  • 안용희;김대영;김은철;박득진
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.21-22
    • /
    • 2005
  • A study on the wear characteristics of the white metal(Sn-base alloy) bearing as a function of particle contamination level was conducted in order to establish control criteria of the lubricant in the 2-stroke marine diesel engine. Particle contamination level of the lubricants ranged from NAS 10 to 12 for the experiments. Bar-on-plate type wear test was performed using reciprocating wear tester. Based on this study it was found that there was no noticeable difference in weight loss of the white metal for NAS10 and NAS11(particle contamination level). Surface roughness of the white metal bearing after the wear test of 8hrs for the highly contaminated lubricant(NAS12 level) was up to $6{\mu}m$ in Rmax whilst that of the less contaminated lubricants(NAS10 & 11) was less than $1.5{\mu}m$ in Rmax.

  • PDF

경기도 시흥군 소래면 뱀내하천 유역의 지하수 오염에 관한 연구 (A study of the pollution of ground water in the basin of the river Baem Nae Chun, Sorae-Myun, Shihoong-gon, Kyonggi-Do, Korea)

  • 김윤종;정봉일
    • 물과 미래
    • /
    • 제6권2호
    • /
    • pp.19-29
    • /
    • 1973
  • The progressive contamination of water resulted from man's activity and the use of fertilizers is not restricted only to surface water, but also the shallow groundwater is affected. This type of groundwater contamination is mainly restricted to areas composed of permeable, nonconsolidated sediments forming a shallow aquifer. The chloride and the sulfate resulted from man's activity and the use of fertilizers were measured to study the variations of the groundwater contamination. In general, (1) When water level rises, the rate of groundwater contamination becomes less and when water level declines, the rate of contamination is increased. (2) The highly contaminated season is the early-summer and the less contaminated season is the winter or after rainy season. (3) The groundwater in weathering zone without covering layer. (4) The degree of contamination of wells is increased with the increase of well depth and lowing the water table, because of increasing contaminated water from enlargement of the area of influence of the well.

  • PDF

돼지도축장의 생물학적 위해요소에 대한 중요관리점 설정 (A study on establishment of bio-hazard analysis and critical control point for pork slaughter house)

  • 옥천석;정지영;송은아;이성식
    • 한국동물위생학회지
    • /
    • 제24권2호
    • /
    • pp.117-126
    • /
    • 2001
  • To ensure the safety of domestic livestock products, the government made it obligatory to enforce the hazard analysis critical control point(HACCP) in all domestic slaughterhouses. Under the HACCP, most of the hazards generated in slaughterhouses are bio-hazards, especially pathogenic bacteria. In order to reduce to the pathogenic bacteria, critical control point (CCP) is established and controled in the process of slaughter. A study was carried out to measure the level of bacterial contamination of swine carcass in 6 slaughterhouses selected. As a result, the aerobic plate counts(cfu/$\textrm{cm}^2$) of all samples was $10^2$-10 in average, except slaughterhouse C. The level of the aerobic plate counts on the surface of lower loin in slaughterhouse C was $10^4$ and it was considered that slaughterhouse C should set the process of manual transport of carcass as the CCP. Escherichia coli level was the highest in middle line cut surface. Especially, E coli level of slaughterhouses C and D were about 6.5- and 3.0-fold higher than that of other 4 slaughterhouses. Thus, it was considered that the slaughterhouses C and D should set the process of the entrails treatment as the CCP. The air contamination was measured at two point in a slaughterhouse. The air contamination level was 4-13 times higher than that of the standard Japanese slaughterhouses.

  • PDF

ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석 (Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구 (Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions)

  • 이신우;김다은;문채원;김갑중;김상하;박혜미;유세종
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.171-177
    • /
    • 2024
  • 본 연구에서는 대전지역 종합병원 중 일반촬영장치, CT, MRI 검사 장치 각 2대씩 선정하여 시간대 별 검사 장치의 표면오염도를 측정하여 감염도를 예측하고 감염 예방을 위한 기초자료로 활용하고자 실험을 하였다. 그 결과 일반촬영장치와 MRI 검사장치의 시간대 별 표면 오염도는 13시>8시>16시 순이였으며, CT검사 장치는 13시>16시>8시 순이었으며 이는 검사 건수의 영향으로 나타났다. 또한 검사 장치 부위 별 표면 오염도 결과는 일반촬영장치는 Stand Bucky 손잡이, CT 검사장치는 머리받침대, MRI 검사 장치는 조작 스위치에서 ATP 오염도 수치가 가장 많이 나왔으며, 이는 접촉 건수와 밀접한 관계가 있었다. 소독 전후를 비교한 결과 소독 후 모든 장치에서 유의한 차이로 감소한 결과를 보였다. 실험 결과를 바탕으로 영상의학과 검사실의 오염도를 파악하고 감염질환을 예방할 수 있는 기초자료가 될 수 있을 것이라고 사료된다.