• Title/Summary/Keyword: Surface Contamination Level

Search Result 161, Processing Time 0.024 seconds

DISTRIBUTION OF VIRUSES IN WATER ENVIRONMENT

  • Lee Seung-Hoon;Cho Hong Baek;Kim Sang-Jong
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2000.05a
    • /
    • pp.94-101
    • /
    • 2000
  • We investigated the viral contamination of water environment including tap water in Korea. River water used for source water was analyzed about monthly between 1997 and 1999 over a period 26 months. A total of 22 tap water samples were collected in 10 sites in 2 urban areas between 1997 and 1998 over a 11 months. All samples were examined for infectious enteroviruses and adenoviruses by a cell culture technique followed by PCR amplification. To identify the recovered viruses from tap water, sequence analysis of PCR products was performed. Infectious viral particles were detected in river water all year round, ranging from 0.93 to 17.3 Most Probable Number of Infectious Unit (MPNIU) /100L. Tap water samples also contained infectious viral particles. The frequency of enteroviruses and adenoviruses in tap water were $50.0\%$ (11/22) and $36.7\%$ (8/22), respectively. Both enteroviruses and adenoviruses were detected in five tap water samples $(22.7\%)$. The level of viral contamination in tap water was quite high, ranging from 0.2 to 2.9 MPNIU/100L, far above the recommended virus level in drinking water set by the U.S. EPA. Poliovirus type 1 derived from vaccine was frequently detected and the remainder comprised coxsackievirus B type or echovirus type 6, which were causative agents of aseptic meningitis in Korea in 1997 and 1998, respectively. Several types of adenovirus were detected in tap water samples and some water samples were found to contain adenoviruses which were closely related to enteric adenovirus type 40 and 41. This stusy shows that surface water and tap water in Korea may be exposed to the risk of viral contamination, especially from recently recognized viruses and this constitutes a potential public health hazard.

  • PDF

Estimation of Pollution Degree of Surface Sediment from Incheon H Wharf (인천 H항 표층 퇴적물의 오염도 평가)

  • Kim, Jeong-Ho;Nam, Se-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.504-510
    • /
    • 2014
  • In this study, physico-chemical properties and pollution degree of surface sediments collected at 5 stations(S1~S5) of Incheon H wharf in March 2014 were investigated. From particle size, surface area, XRD and XRF analyses, the sediment samples consisted of similar oxides and minerals. Considering total score of COD, AVS and IL, pollution level ranged between 2 and 3 based on domestic standards. In case of heavy metal contamination, Cd, Ni and Pb were classified as moderately polluted by USEPA standards. However, Cu, Zn and Cr were classified as heavily polluted. With geoaccumulation index value($I_{geo}$), Cd contamination was estimated as class 3. In addition, the calculated enrichment factors of Cd, Pb and Zn were exceeded a value of 1. Site S4 was high as 3.1 in total enrichment factor.

Level and Origin of Polycyclic Aromatic Hydrocarbons (PAHs) in Sediments from Ulsan Bay, Korea

  • Moon, Hyo-Bang;Park, Hee-Gu;Kim, Sang-Soo;Lee, Pil-Yong
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.113-119
    • /
    • 2001
  • Surface sediments(0~5 cm) were sampled from 22 stations in Ulsan Bay, one of the most highly industrialized regions in Korea, in November 2000. The sediment samples were analyzed for their polycyclic aromatic hydrocarbon(PAH) content using a gas chromatography coupled to a mass spectrometer detector(GC/MSD). The total PAH concentrations in the sediments varied from 14 to 7108 ng/g dry weight with a mean value of 1052 ng/g dry weight. The level of carcinogenic PAHs ranged from 6 to 2396 ng/g dry weight with a mean value of 433 ng/g dry weight. The highest PAH concentrations in the sediments from Ulsan Bay were found at Station U8, whereas the lowest levels were observed at Stations U2 and U 17. The PAH distribution exhibited a decreasing gradient from the inner basin to the outer bay. The predominant contributors to the aromatic ring groups of the 16 PAHs were four- and five-ring groups, such as fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzor[b]fluoranthene, benzor[k]fluoranthene and benzo[a]pyrene, while two- and three-ring aromatics, like naphthalene, acenapthylene, acenaphthene, fluorene, phenanthrene and anthracene, only exhibited a low concentration. The molecular indices for phenanthrene/anthracene and fluoranthen/pyrene were used to Identify the origin of the PAH contamination in the sediments. The results indicated that the PAH contamination in Ulsan Bay was mostly Pyrolytic in origin with a Petrogenic input adjacent to Ulsan and Jangsuengpo harbor.

  • PDF

Assessment of Pollution Characteristics of Surface Sediments from Andong Lake(I): Studies on Characteristics of Pollution of Sediments from Andong Dam (안동댐 퇴적물의 오염도 평가(I): 안동댐 퇴적물의 오염 특성 연구)

  • Kim, Young Hun;Park, Jae Chung;Shin, Tae Cheon;Kim, Jeong Jin
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.4
    • /
    • pp.377-389
    • /
    • 2020
  • In this study, pollution characteristics were investigated for the Andong Dam sediments in the Nakdong River. Sediment samples were collected from the middle, left, and right points of the lake up to 40km upstream of the Andong Dam at intervals of about 5km by stratification and turnover period. In the case of nutrients and total organics such as loss of ignition, total nitrogen, and phosphorus, the degree of contamination is low, but heavy metals of arsenic and cadmium is very high. The contamination level of sediments in the dam area is higher than that of the branch of river and the control group, and concentration of chromium, copper, and lead are higher in the stratification period, and that of zinc is higher in turnover period. Arsenic, cadmium, manganese, and zinc showed contamination variation between upstream and downstream but chromium, copper, mercury, iron and lead didn't show the variation.

Disinfection Effect of Film Cassettes by Ultraviolet Irradiation (자외선을 이용한 Film Cassette의 소독 효과)

  • Kweon, Dae-Cheol;Park, Peom
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.425-432
    • /
    • 2001
  • A bacteria infection on film cassette contact surface was examined at the diagnostic radiology department. Studies have demonstrated a bactericidal effect of ultraviolet irradiation, and to assess the contamination level on film cassette contact surface as a predictor of patient prevent from nosocomial infection. The study showed that the laboratory result was identified non-pathologic and pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection practices suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In conclusion, ultraviolet irradiate on film cassette over the surface more than 2 minutes. Ultraviolet dose of $1565 {\mu}W{\codt}s/cm^2$ Win in 30 second relative to ultraviolet dose in time.

  • PDF

The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants (수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구)

  • Kim, Sun-bong;Yim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF

Cation Exchange Capacity and Zeta Potential Characteristics of Kaolinite Contaminated with Lead (납으로 오염된 카올리나이트의 양이온교환능력 및 계면동전위 특성)

  • 장경수;강병희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.38-43
    • /
    • 2002
  • A series of tests were performed to investigate the effects of pH and contamination level on cation exchange capacity and zeta potential in kaolinite loaded with lead. Test results show that cation exchange capacity of kaolinite is found to be in the range from 4 to 20meq/100g and it increased with increasing pH up to the converged number about 20meq/100g over pH 8. And then CEC has a tendency to reduce and converge to zero with increasing the concentration of Pb in the kaolinite surface. Moreover, zeta potential of kaolinite contaminated with lead is found to be in the range from -10 to 5mV, and zero point of charge is measured at about pH 3.5. Zeta potential of kaolinite contaminated with lead decreases with increasing pH values and decreasing Pb concentration of kaolinite.

  • PDF

Distribution of Heavy Metals in the Soils of Hanam City. (경기도 하남시 토양의 중금속 함량 분포 조사)

  • Kim, Kye-Hoon;Kim, Kwon-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.345-350
    • /
    • 2000
  • The objectives of this study were to find out distribution of heavy metal contents in the soils of Hanam city and to provide base-line data towards development of an eco-city Hanam. One hundred surface soil (0-20 cm) samples were collected from rice paddy field, cultivated upland, forest, riverside and other areas. The samples were air-dried, sieved to pass through 2 mm sieves, followed by analyses for As, Cd, Cu, Pb and Zn by the standard method set by the ministry of environment. All the average heavy metal contents were close to background level and were much lower than concern level of the Soil Environment Conservation Act of Korea. However, some individual heavy metal contents were higher than the action level. Since natural environment including soil environment of Hanam city is being destroyed rapidly and the number of the sampling points allocated to Hanam city based on the soil contamination monitoring network of the ministry of environment is only 6, an in-depth soil survey for contamination of Hanam city is highly recommended.

  • PDF

Characteristics of Fancy Veneer Plywood Floor using Green Tea Leaves Powder (녹차잎분말을 사용한 마루판의 특성)

  • Kang, Seog-Goo;Lee, Hwa-Hyoung
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.4
    • /
    • pp.284-292
    • /
    • 2010
  • This research was carried out to examine the properties of fancy cherry veneer overlaid on the PF resin bonded Meranti plywood floor, which 2.5% green tea leaf powder was applied in the UV varnishes and the adhesives for scavenging the volatile organic compounds. The results were as follows: 1. The various properties of the treated samples, such as density, moisture content, thickness swelling, bending strength(MOR), adhesion shear strength, surface abrasion, curling, cyclic delamination test with boiling water, boiling property, cold-resistance and heat resistance, acid resistance and alkali resistance, and anti-contamination property showed no significant difference between the properties of the control samples. 2.5% green tea leaf powder treated floor gave a little better results than the control for surface scratch test. 2. In case of QUV and weathering test, no difference between the treated sample and control was found. 3. The floor was discolored by adding 10% green tea leaf powder to UV coating, and the floor was also discolored to light green during by the soaking test. The color of floor was not changed up to 5% addition level.

  • PDF

Hydrogeochemical Environmental Research in Nitrate Contamination in Alluvial Fan Area Groundwater in Tsukui, Central Japan (일본 츠꾸이 선상지 지하수의 질산성 질소 오염에 대한 수문지구화학적 연구)

  • Okazaki, Masanori;Ham, Young-Sik
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.4 s.109
    • /
    • pp.431-435
    • /
    • 2004
  • A nitrate-contaminated groundwater was hydrogeochemically investigated to estimate the factors controlling groundwater quality in an alluvial fan area. Even though monthly groundwater levels increased with monthly rainfalls, the monthly $NO_3^--N$ concentrations in groundwater showed a small variation, mostly exceeding a maximum contaminant level of 10 mg $L^{-1}$ in environmental quality standards for groundwater during 2003. The 2003 annual groundwater recharge was 1,730 mm =20,056 mm-18,326 mm. Where 20,056 mm and 18,326 mm are annual sum of daily increase and decrease in ground water level. However, the annual sum of increase in ground water level (20,056 mm) was approximately 10 times higher than annual rainfall. Moreover, the annual sum of daily ground water level decrease (-18,326mm) showed that a large amount of groundwater was discharged with $NO_3^-$-contamination. Hydrogeochemically, a large amount of groundwater input and output through the alluvial fan area were observed after rainfall with a considerably high concentration of $NO_3^-$. Consequently, this alluvial fan area including forest area reflects on the evidence under the condition of 'nitrogen excess' or 'nitrogen saturation'. In addition, such a large amount of groundwater outflow can cause environmental damage in surface water, associated with $NO_3^-$- contamination. This study also expects that this hydrogeochemical data will be useful for water management.