Free-form Surface Generation from Measuring Points using Laser Scanner

  • Park, Jae-Won;Hur, Sugn-Min;Lee, Seok-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권4호
    • /
    • pp.15-23
    • /
    • 2002
  • With the development of a laser scanner of high precision and increased speed, reverse engineering becomes a key approach to reduce the time for the development of new products. But the modeling process is not so automated enough until now. Modeling in real workshops is usually performed by the experienced operators and it requires a skillful technique to get the resultant surface of high quality and precision. In this paper, a systematic solution is proposed to automate the free-form surface generation from the measured point data. Compatibility is imposed to the measured point data during input curve generation. And the compatibility of cross-sectional curve is also considered for the loft surface generation. The data in each step is produced in IGES file format to make an easy interface to other CAD/CAM software without any further data manipulation.

시스틴으로 화학흡착된 금 코팅 니티놀 표면에 앙쪽성 이온 폴리에틸렌글리콜의 그래프트 및 특성 평가 (Grafting and Characterization of Zwitter Ionic Poly(ethylene glycol) on Gold-Coated Nitinol Surface Chemisorbed with L-Cysteine)

  • 신홍섭;박귀덕;김재진;김지흥;한동근
    • 폴리머
    • /
    • 제33권1호
    • /
    • pp.84-90
    • /
    • 2009
  • 니티놀(Nitinol) 합금(TiNi)은 혈관 스텐트로서 널리 사용되고 있다. 본 연구에서는 니티놀 합금의 혈액적 합성을 개선시키기 위해서 화학적인 표면개질을 행하였다. 먼저 니티놀의 표면을 금으로 코팅한 다음 시스턴(L-cysteine, C/N)을 화학흡착한 후 신규 합성한 양쪽성 이온 폴리에틸렌글리콜(PEG) (PEG-$N^+-SO_3{^-}$)을 그래프트 시켜서 TiNi-C/N-PEG-N-S를 제조하였다. 양쪽성 이온 PEG가 그래프트된 니티놀의 표면은 ATR-FTIR, ESCA 및 SEM을 통해서 확인하였고 친수성 표면은 물 접촉각의 감소를 통해서 입증하였다. 또한, 단백질 흡착 및 혈소판 점착과 혈액응고시간 측정과 같은 혈액적합성 평가 결과로부터 미처리 니티놀 합금에 비해서 표면개질된 니티놀 합금이 상대적으로 훨씬 우수한 혈액적합성을 나타내었다. 이는 그래프트된 친수성 PEG와 항응혈성 양쪽성 이온의 상승효과에 의해서 혈액적합성을 대폭 개선시킨 것으로 사료된다.

접촉면에서 모든 적합조건을 만족시키는 동적인 접촉현상의 해법 (Dynamic Contact Analysis Satisfying All the Compatibility Conditions on the Contact Surface)

  • 이기수
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1243-1250
    • /
    • 1995
  • For the numerical solution of frictional dynamic contact problems, correct contact points and displacements are determined by iteratively reducing the displacement error vector monotonically toward zero And spurious oscillations are prevented from the solution by enforcing the velocity and acceleration compatibilities of the contact points with the corresponding error vectors. Numerical simulations are conducted to demonstrate the accuracy of the solution and the necessity of the velocity and acceleration compatibilities on the contact surface.

Energy Based Multiple Refitting for Skinning

  • Jha, Kailash
    • International Journal of CAD/CAM
    • /
    • 제5권1호
    • /
    • pp.11-18
    • /
    • 2005
  • The traditional method of manipulation of knots and degrees gives poor quality of surface, if compatibility of input curves is not good enough. In this work, a new algorithm of multiple refitting of curves has been developed using minimum energy based formulation to get compatible curves for skinning. The present technique first reduces the number of control points and gives smoother surface for given accuracy and the surface obtained is then skinned by compatible curves. This technique is very useful to reduce data size when a large number of data have to be handled. Energy based technique is suitable for approximating the missing data. The volumetric information can also be obtained from the surface data for analysis.

원심 임펠러의 설계기술 개발 (Development of a Design Technique for Centrifugal Impellers)

  • 윤의수;최범석;최태민
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.5-19
    • /
    • 1992
  • An aerodynamic design technique of a centrifugal impeller is developed. The design procedure consists of a preliminary design, a three-dimensional blade surface generation, a flow analysis of impeller passage and a compatibility analysis for the designed impeller. To get a higher efficiency, the backswept impeller which has a lean angle and a parabolic blade surface is designed. In the present analysis of flow in an impeller, an inviscid quasi-three-dimensional method and a viscous three-dimensional method are used. Compatibility of the designed impeller is decided with the results of the analyses. The quasi-three-dimensional method is easy to use, but limited to a few conditions in real application for the prediction of the actual flow in the impeller. Since the viscous three-dimensional method proved to predict the real flow in the impeller relatively well, it can be used as a means for the decision of compatibility of the designed impeller.

  • PDF

Surface Structure of Blend Films of Styrene/Acrylonitrile Copolymer and Poly(methyl methacrylate)(PMMA) or Hydrolyzed PMMA

  • 이원기;K. Tanaka;A. Takahara;T. Kajiyama;하창식
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권9호
    • /
    • pp.958-961
    • /
    • 1997
  • The compatibility and the surface structure of blends of poly(styrene-co-acrylonitrile) (SAN) with either poly(methyl methacrylate) (PMMA) or hydrolyzed PMMA (H-PMMA) were studied in terms of film thickness, interaction, and surface free energy difference on the basis of X-ray photoelectron spectroscopy (XPS), attenuated total reflection Fourier transform IR spectroscopy and atomic force microscopy. The XPS measurement showed that the surface enrichment of (PMMA/SAN) blends with different AN contents of SAN and with different carboxyl acid contents of PMMA was dependent on the molecular interaction, the surface free energy difference between components and the sample preparation history. It was found that the compatibility of H-PMMA and SAN was reduced with increasing carboxyl acid content of PMMA.

보철용 지르코니아 어버트먼트의 표면적합도와 전기화학적 거동 (Surface Compatibility and Electrochemical Behaviors of Zirconia Abutment for Prosthodontics)

  • 박근형;정용훈;김원기;최한철;김명수
    • 한국표면공학회지
    • /
    • 제42권1호
    • /
    • pp.41-46
    • /
    • 2009
  • The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at $1500^{\circ}F$ for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was $5{\sim}12{\mu}m$ for small gap, and $40{\sim}60{\mu}m$ for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/fixture was .290 mV and metal abutment/fixture was .280 mV, whereas $|E_{pit}-E_{corr}|$ of zirconia abutment/fixture (172 mV) was higher than that of metal abutment/fixture (150 mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

세포적합성 고분자 표면에 관한 연구 II. 표면 개질된 고분자에의 세포 배양 (Polymer Surfaces for Cell Adhesion II. Cell Culture on Surface-modified Polymers)

  • 이진호;강길선
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.195-202
    • /
    • 1989
  • Chinese Hamster Ovary( CHO) cells were cultured on the surface-modified polymers described in the previous study( "Polymer Surfaces for Cell Adhesion. 1. Surface Modification of Polymers and ESCA Analysis, " J. of KOSOMBE, Vol. 10, No. 1, 43-51, 1989). Among the physicochemical treatment methods. the chloric acid treatment was found to be the best method of rendering the polymer surfaces adhesive for CHO cells probably due to the high density of hydroxyl groups on the surface. Among the biological methods, the fibronectin treatment was best for CHO cell-compatibility probably due to specific active sites existed on the tell-binding domains of the fibronectin structure. When we compare the cell-compatibility of the chloric acid - and the fibronectin -treated PET surfaces, the number of cells attached on the surfaces were increased by 460.5 % and 559.0 % and, respectively, after 32 hr CHO cell culture, compared to that of untreated PET.eated PET.

  • PDF

Enhancement of Compatibility between Ultrahigh-Molecular-Weight Polyethylene Particles and Butadiene-Nitrile Rubber Matrix with Nanoscale Ceramic Particles and Characterization of Evolving Layer

  • Shadrinov, Nikolay V.;Sokolova, Marina D.;Okhlopkova, A.A.;Lee, Jungkeun;Jeong, Dae-Yong;Shim, Ee Le;Cho, Jin-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3762-3766
    • /
    • 2013
  • This article examines the modification of surface properties of ultrahigh-molecular-weight polyethylene (UHMWPE) with nanoscale ceramic particles to fabricate an improved composite with butadiene-nitrile rubber (BNR). Adhesion force data showed that ceramic zeolite particles on the surface of UHMWPE modulated the surface state of the polymer and increased its compatibility with BNR. Atomic force microscopy phase images showed that UHMWPE made up the microphase around the zeolite particles and formed the evolving layer with a complex interface. The complex interface resulted in improvements in the mechanical properties of the composite, especially its low-temperature resistance coefficients, thereby improving its performance in low-temperature applications.