• 제목/요약/키워드: Suppression current

검색결과 361건 처리시간 0.026초

V/F 제어 고속 유도전동기의 전류 진동 억제 방법 (Suppression method for current oscillation of V/F controlled high speed induction motor)

  • 이진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.150-151
    • /
    • 2017
  • This paper deals with the suppression of subharmonic current oscillation of V/F controlled high speed induction motor drive in turbo blower applications. High speed induction motor has a relatively low stator impedance for high speed operation and therefore the dc link voltage ripple may result in subharmonic current oscillation at the steady state in high speed operation. This paper shows that the subharmonic oscillation is caused by the dc link voltage ripple and also proposes the suppression method, which generates the compensation voltage through the proportional current controller to reduce the subharmonic current oscillation. The simulation and experimental results show that the proposed suppression method reduces the subharmonic current oscillation to the acceptable low level in turbo blower applications.

  • PDF

자석과 코일을 이용한 빔의 진동 억제 (Vibration Suppression of Beam Using Magnet and Coil)

  • 성태홍;정정환;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.727-730
    • /
    • 2007
  • Coil inductor has been used widely as an electromagnet, because of the high magnetic filed resulting from the voltage applied to the coil. In this study the coils were used in vibration suppression as an actuator. The control system consists of a coil attached in aluminum beam and a permanent magnet set at its bottom. This actuation method is easy to be incorporated into the system and allows significant forces to be applied without contacting with the structure. Three types of coils (cylindrical type, square type, Circular sheet type) were employed in vibration suppression of cantilever beam. The positive position feedback (PPF) controller was applied to the magnet-coil actuator to suppress the first mode of vibration. Experimental results showed that the cylindrical type and square type coil made good vibration suppression efficiency under PPF controller than their eddy current damper. However, there was minimal difference for the circular sheet type coil if compared with its eddy current damper.

  • PDF

단전원 듀얼 인버터의 데드타임으로 인한 영상전류 억제 방법 (Suppression of Zero Sequence Current Caused by Dead-time for Dual Inverter With Single Source)

  • 윤범렬;김태형;이준희;이준석
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.126-133
    • /
    • 2022
  • This study proposes a suppression of zero sequence current (ZSC), which is caused by zero sequence voltage (ZSV) for a dual two-level inverter with single DC bus. Large output voltages enable the dual inverter with single DC bus to improve a system efficiency compared with single inverter. However, the structure of dual inverter with single DC bus inevitably generates ZSC, which reduces the system efficiency and causes a current ripple. ZSV is also produced by dead time, and its magnitude is determined by the DC bus and current direction. This study presents a novel space vector modulation method that allows the instantaneous suppression of ZSC. Based on a condition where a switching period is twice a sampling (control) period, the proposed control method is implemented by injecting the offset voltage at the primary inverter. This offset voltage is injected in half of the switching period to suppress the ZSC. Simulation and experiments are used to compare the proposed and conventional methods to determine the ZSC suppression performance.

고조파 유출 억제기술의 동향 (The Trend of suppression technology of harmonics for distribution system)

  • 고희석;이현무;이충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.330-332
    • /
    • 2004
  • Reliance on electric power has increased together with customer's demand for delightful and convenient linging. Recently, as appeared in the rapid growth of the technology of power electronics, the installation and apparatus using semiconductor applicotion is widly supplied and used from a household goods to industrial goods. However, these machine generate harmonics current and voltage for electric power system. The harmonics current is increased voltage distortion and generate a lot of interference in the electric power system. In this paper, the trend of the trend of suppression technology of harmonics outflow and the fundamental theory about the suppression of harmonics current in the distribution system are investigated and evaluated Therefore we look forward to supply electric power of good quality to satisfy the harmonics current guide line which is applied to household goods in the world.

  • PDF

스위치의 선형영역을 이용한 무효전력보상기의 돌입전류 억제 방안 (Inrush Current Suppression Method of the Reactive Power Compensator by using a Linear Region of the Switch)

  • 박성미;강성현;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.55-64
    • /
    • 2013
  • In this paper, a new topology which can add a small reactor in series to a condenser-bank type reactive power compensator to limit current is proposed. And also the proposed topology can add or remove a power condenser safely without any addition of inrush-current suppression resistance. The proposed method tests variable resistance of the drain source of a switching device which is controlled by gate voltage in a two-way switch with a diode rectifier and FET switch. In other words, the proposed method is a inrush-current suppression method with the structure of variable resistance. In particular, the proposed method creates smooth current without any resonance in inrush-current as well as is not limited by the time of switch on and off.

Control Strategy and Characteristic Analysis of Hybrid Active Power Filters with the Resonant Impedance Principle

  • Fang, Lu;Xu, Xian-Yong;Luo, An;Li, Yan;Tu, Chun-Ming;Fang, Hou-Hui
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.935-946
    • /
    • 2012
  • A new kind of resonant impedance type hybrid active filter (RITHAF) is proposed for dynamic harmonic current suppression and high capacity reactive compensation in medium and high voltage systems. This paper analyzed the different performance of the RITHAF when the active part of the RITHAF is controlled as a current source and as a voltage source, respectively. The harmonic suppression function is defined in this paper. The influences of the changes caused by the grid impedance and the detuning of the passive power filter on the compensating characteristics of the RITHAF are studied by analyzing the suppression function. Simulation and industrial application results show that the RITHAF has excellent performances in harmonic suppression and reactive compensation, which is suitable for medium and high voltage systems.

Novel Method for Circulating Current Suppression in MMCs Based on Multiple Quasi-PR Controller

  • Qiu, Jian;Hang, Lijun;Liu, Dongliang;Geng, Shengbao;Ma, Xiaonan;Li, Zhen
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1659-1669
    • /
    • 2018
  • An improved circulating current suppression control method is proposed in this paper. In the proposed controller, an outer loop of the average capacitor voltage control model is used to balance the sub-module capacitor voltage. Meanwhile, an individual voltage balance controller and an arm voltage balance controller are also used. The DC and harmonic components of the circulating current are separated using a low pass filter. Therefore, a multiple quasi-proportional-resonant (multi-quasi-PR) controller is introduced in the inner loop to eliminate the circulating harmonic current, which mainly contains second-order harmonic but also contains other high-order harmonics. In addition, the parameters of the multi-quasi-PR controller are designed in the discrete domain and an analysis of the stability characteristic is given in this paper. In addition, a simulation model of a three-phase MMC system is built in order to confirm the correctness and superiority of the proposed controller. Finally, experiment results are presented and compared. These results illustrate that the improved control method has good performance in suppressing circulating harmonic current and in balancing the capacitor voltage.

와전류 감쇠기를 이용한 진동 억제 (Vibration Suppression Using Eddy Current Damper)

  • 곽문규;이명일;허석
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.760-766
    • /
    • 2003
  • This paper is concerned with the eddy current damper which can be used to enhance the damping of the host structure. The operating principle of the eddy current damper is first explained in detail. The dynamic interaction between the magnets and the copper plate produces eddy current thus resulting in the damping force. By attaching the eddy current damper to the host structure, the damping of the total structure can be increased so that vibrations can be suppressed. The advantage of the eddy current damper is that it doesn't require any electronic devices and power supply The effect of the eddy current damper on the global dynamic characteristics of the structure is investigated by considering the cantilever with the eddy current damper. Experimental results show that the eddy current damper is an effective device for vibration suppression.

npn MOS 영상소자의 블루밍억제에 관한 연구 (Blooming Suppression of an npn MOS Image Sensor)

  • 갑형철;민홍식;이종덕
    • 대한전자공학회논문지
    • /
    • 제25권4호
    • /
    • pp.417-421
    • /
    • 1988
  • In order to analyze the blooming suppression mechanism of a MOS image sensor, test photodiodes have been fabricated and characterized by attaching a source follower circuit. The blooming suppression ability of npn structure compared to that of np structure is quantitatively analyzed and measured by experiment. The dependency of the blooming current on the substrate voltage, the vertical MOS gate voltage and the video voltage is measured and the optimum condition for blooming suppression is presented.

  • PDF

MTMD를 이용한 보의 진동 억제 (Vibration Suppression of a Cantilever Beam Using MTMD)

  • 배재성;황재혁;김종혁;임재혁
    • 한국소음진동공학회논문집
    • /
    • 제21권12호
    • /
    • pp.1091-1097
    • /
    • 2011
  • In the present study, TMD(tuned mass damper) with eddy current damping is proposed to suppress the vibration of a cantilever beam effectively. The advantages of TMD are that it is simple and its performance are excellent at any particular frequency. However, TMD may have the low performance at other frequency. To solve this problem and improve its performance, this study applies the eddy current damping to TMD. This TMD with ECD is named as MTMD(magnetically tuned mass damper). MTMD is designed for the vibration suppression of a cantilever beam. The mathematical modeling, simulation, and experiments of the cantilever beam with MTMD are performed. From analytic and experimental results, it can be concluded that the vibration suppression performance of MTMD are excellent.