• Title/Summary/Keyword: Support Device

Search Result 1,021, Processing Time 0.021 seconds

A Study on the Accuracy and Convenience of Imaging Method Using Support Device in Knee Joint Lateral Radiography (슬관절의 측면 방사선 촬영에서 보조기구를 이용한 검사방법의 정확성과 편의성에 대한 연구)

  • Uhm, Soyeong;Cho, Yongkeun;Kang, Sungjin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.253-262
    • /
    • 2017
  • In lateral projection imaging method of knee joint, a method that adjusts the incidence angle of central X-ray toward the head side to $5{\sim}7^{\circ}$ in true lateral position which is existing recommended is called imaging method A, Method of imaging the central X-ray perpendicular to the horizontal plane of the examination table toward the knee is called imaging method B, and a method in which the central X-ray is perpendicularly applied to the joints while the lateral side of the distal tibia is compensated by radiolucent materials is called as method C. After tests each imaging method to classified study subject respectively, the joint space distance and the distance between lateral and medial condyle of femur were measured and compared as the quantitative index from the three imaging methods. In addition, the convenience of each imaging method was confirmed through questionnaires to practician. According to the result of the quantitative index, there is no statistically significant difference in imaging method A and C(p>0.05). However, imaging method B showed a significant difference in both A and C(p<0.05). As a result of evaluating the convenience of the imaging method, imaging method A was relatively assessed lower in all items than imaging methods B and C, and as a small difference, imaging method B is assessed higher than C. In this study suggested new knee joint lateral projection imaging method, by using a simple support device, could describe joint space as not much different as existing recommended method without some complex process, and could increase convenience of the practician in the process of the imaging.

Fast Handover Mechanism for Efficient Mobility Support in ZigBee Networks (지그비 네트워크에서 효율적인 이동성 지원을 위한 빠른 핸드오버 방안)

  • Jeong, Woo-Jin;Kim, Ki-Beom;Choi, Chang-Soon;Yoon, Dong-Weon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.78-84
    • /
    • 2006
  • This paper proposes a method to endow the mobility to the Zigbee protocol which is a short distance wireless communication technology among the standards of wireless sensor networks. The Zigbee has a low price, long life battery, simple structure and connectivity. So it is a suitable standard for the short distance wireless communication of $10m{\sim}70m$. As the Zigbee does not support the mobility, additional factors should be studied to deal adeptly with the diverse change in the real field. By solving the problem that the previous connection and binding table of the Zigbee end device should be reset due to the Zigbee end device address variation when the Zigbee end device moves from the present router to another router, this paper presents the method to communicate without data loss or disconnection.

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.

The Device Configuration Protocol with Real-Time Processing for QoS Support over IPv6 (IPv6 상에서 QoS 지원을 위한 실시간 처리용 DCP 프로토콜)

  • Joe, In-Whee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10B
    • /
    • pp.660-668
    • /
    • 2005
  • Recently, the Internet-based communication method has been adopted as an open networking solution in the field of remote control and data acquisition. In the current Internet, most networking applications are developed according to the client-server approach. In this paper, we propose an innovative Device Configuration Protocol (DCP) that exchanges the traditional role between client and server to provide a uniform device interface over the Internet for various field devices. The proposed protocol is implemented as an application-level protocol running on top of the standard TCP/IP protocols. Also, the DCP protocol is extended with real-time processing to work with the FlowLabel of IPv6 for QoS (Quality of Service) support. The simulation results show that the real-time packets can be processed prior to the given deadline regardless of throughput, as compared to the normal packets.

Optimal Design of a Novel Knee Orthosis using a Genetic Algorism (유전자 알고리즘을 이용한 새로운 무릎 보장구의 최적 설계)

  • Pyo, Sang-Hun;Yoon, Jung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.10
    • /
    • pp.1021-1028
    • /
    • 2011
  • The objective of this paper is to optimize the design parameters of a novel mechanism for a robotic knee orthosis. The feature of the proposed knee othosis is to drive a knee joint with independent actuation during swing and stance phases, which can allow an actuator with fast rotation to control swing motions and an actuator with high torque to control stance motions, respectively. The quadriceps device operates in five-bar links with 2-DOF motions during swing phase and is changed to six-bar links during stance phase by the contact motion to the patella device. The hamstring device operates in a slider-crank mechanism for entire gait cycle. The suggested kinematic model will allow a robotic knee orthosis to use compact and light actuators with full support during walking. However, the proposed orthosis must use additional linkages than a simple four-bar mechanism. To maximize the benefit of reducing the actuators power by using the developed kinematic design, it is necessary to minimize total weight of the device, while keeping necessary actuator performances of torques and angular velocities for support. In this paper, we use a SGA (Simple Genetic Algorithm) to minimize sum of total link lengths and motor power by reducing the weight of the novel knee orthosis. To find feasible parameters, kinematic constraints of the hamstring and quadriceps mechanisms have been applied to the algorithm. The proposed optimization scheme could reduce sum of total link lengths to half of the initial value. The proposed optimization scheme can be applied to reduce total weight of general multi-linkages while keeping necessary actuator specifications.

Discovery of Proximate Devices with Partial Information for Device-to-Device Communication Systems (디바이스 간 직접통신 시스템을 위한 부분 정보를 이용한 근거리 디바이스 발견)

  • Yeo, Gyu-Hak;Chae, Seung-Yeob;Rim, Min-Joong;Kang, Chung G.;Yeh, Choong-Il;Ahn, Jae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.5
    • /
    • pp.328-336
    • /
    • 2013
  • One of the important processes in device-to-device communication is the discovery of proximate devices. In order to perform precise discovery of devices, the distance information among all the device pairs should be gathered by each device sending a discovery signal in turn and the other devices receiving the signal. However, periodic discovery signal transmission by every device might require too long discovery period or too large resource for discovery. Above all, some discovery information might be lost due to several practical reasons and it may take substantial amount of time to obtain all the necessary information. In this paper, we propose a proximate-device-discovery method using partial discovery information in order to reduce the resource for discovery and support the cases in which some discovery information can be lost. We also discuss discovery probabilities with partial discovery information.

Development of an intelligent edge computing device equipped with on-device AI vision model (온디바이스 AI 비전 모델이 탑재된 지능형 엣지 컴퓨팅 기기 개발)

  • Kang, Namhi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.17-22
    • /
    • 2022
  • In this paper, we design a lightweight embedded device that can support intelligent edge computing, and show that the device quickly detects an object in an image input from a camera device in real time. The proposed system can be applied to environments without pre-installed infrastructure, such as an intelligent video control system for industrial sites or military areas, or video security systems mounted on autonomous vehicles such as drones. The On-Device AI(Artificial intelligence) technology is increasingly required for the widespread application of intelligent vision recognition systems. Computing offloading from an image data acquisition device to a nearby edge device enables fast service with less network and system resources than AI services performed in the cloud. In addition, it is expected to be safely applied to various industries as it can reduce the attack surface vulnerable to various hacking attacks and minimize the disclosure of sensitive data.

Frequency Resource Obtaining Method Based on D2D Device Discovery in Public Safety Communication Networks (재난 무선통신을 위한 D2D 단말탐색 기반 주파수 자원 확보 기술)

  • Wu, Shanai;Shin, Oh-Soon;Shin, Yoan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1440-1442
    • /
    • 2016
  • As long term evolution (LTE) is the most widely deployed broadband communication technology so far, efforts are being made to develop LTE-based mission critical public safety (PS) communication systems. In this paper, we propose a device-to-device (D2D) discovery-based radio resource acquisition scheme to support the LTE D2D communication to PS systems and the realization of resource forwarding for user equipments in emergency area.

Development of portable game device with uncompressed HD video and high quality sound output (비압축 HD급 영상 및 고음질 음성 출력을 지원하는 휴대용 게임기 구현)

  • Lee, Chung-Hee;Lee, Jong-Hun;Jung, Woo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.391-393
    • /
    • 2006
  • In this paper, we develop a portable game device with uncompressed HD video and high quality sound output. Portable game devices support not only game function but also various complex functions recently. It especially supports TV-Out port to play realistic game, connecting a large screen display device. But the video and audio output signals of conventional TV-out port have the low performance and these signals are analog output. So, it is difficult that the users enjoy realistic game with benefit of high resolution digital TV. We propose the game device output with uncompressed digital signal, which has no delay of video/audio signal, also has strong immunity to external noise. Since it supports a high resolution video and high quality sound, users can playa realistic game. First, we implement the HDMI to the game device and we test reliability with the various resolutions video inputs and audio inputs. The proposed method can be applied multimedia devices requiring high performance output function as well as portable devices.

  • PDF

State and subject of health and sports medical devices industry at oversea

  • Seo, Jung-Hwa;Kim, Se-Jin
    • Journal of Sport and Applied Science
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • Most of people do not remind of 'Who is domestic medical device business?' A lot of people that Johnson and Johnson, GE and Philips and other foreign companies belong to medical device company. In fact, local enterprises small place based on world market. Local medical device industry's production has grown up rapidly last 10 years. Sales increased nearly 3 times from trillion and 500 billion KRW in 2004 to 4 trillion and 600 billion KRW in 2014. The production record constantly increased owing to safety and good quality of domestic medical devices. As many as 59% of medical devices made in Korea is exported to 198 countries in the world. Currently, medical device industry in the world has been given considerable attention. Cognition and awareness are very much low. Medical device industry, high income creating industry, is said to next generation industry to increase scale, and Korea does not follow world flow. The industry is given support from the government that is not enough. Korean enterprises have small scale among a lot of global enterprises. Being interested in development of medical devices, the author selected department of IT at college.