A Mobile Office Support System: Applying Remote Data Synchronization and Device Management Methods (모바일 오피스 지원시스템: 원격 자료동기화와 장비관리 방법 적용)

  • Pak, Ju-Geon;Park, Kee-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.137-148
    • /
    • 2010
  • In this paper, a mobile office support. system which consists of mobile devices and servers is proposed. An efficient mobile office support system is required to study since the existing mobile office support systems may face the serious problems such as an absence of interoperability, difficulties of data synchronization and device management in the near future, especially when a company has a large number of outdoor service employees. In this paper, a mobile office support system requirements for a company with a large number of outdoor service employees is proposed. And then, the methods to satisfy the requirements using a remote data synchronization and a remote device management technologies are proposed. The mobile office support system proposed in this paper synchronizes remotely a large number of various mobile devices of employees with centralized servers located in the company. In addition, it manages the mobile devices remotely for the employees. This paper proposes a mobile office support system based on OMA(Open Mobile Alliance) DS(Data Synchronization) and DM(Device Management) protocols. As OMA DS and DM protocols are de facto international standards, the interoperability between the mobile office support systems can be guaranteed.

Power Support Device (PSD) Based Authentication Protocol for Secure WiBro Services (안전한 WiBro 서비스를 위한 PSD(Power Support Device) 기반 인증 프로토콜)

  • Lee, Gi-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.727-733
    • /
    • 2008
  • An authentication between a user's terminal and a Access Control Router (ACR) is preceded so that a user receives secure WiBro services. Otherwise they can be exposed from many attack risks. So the Telecommunications Technology Association (TTA) constituted a mechanism of the mutual authentication for WiBro service. In mechanism a user executes the mutual authentication between a Portable Equipment (PE) and the ACR by using Portable Internet Subscriber Identity Module (PISIM). But this standard needs many message to authenticate the ACR and the users cann't use wireless Internet service. Therefore in this paper we propose the key agreement protocol between the PSS and the ACR to authenticate the PSS to ACR. At this time Power Support Device (PSD) fer supporting the calculated quantity of the PSS is participated in the key agreement protocol. The ACR sends a generated key to Key Authentication Server (KAS) via secure IPsec tunnel and then it preserves the identity of the PSS and the value of key after it enciphered them. In conclusion we analyze the security and efficiency of the proposed protocol.

Use of Acellular Biologic Matrix Envelope for Cardiac Implantable Electronic Device Placement to Correct Migration into Submuscular Breast Implant Pocket

  • Peyton Terry;Kenneth Bilchick;Chris A. Campbell
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.156-159
    • /
    • 2023
  • Breast implants whether used for cosmetic or reconstructive purposes can be placed in pockets either above or below the pectoralis major muscle, depending on clinical circumstances such as subcutaneous tissue volume, history of radiation, and patient preference. Likewise, cardiac implantable electronic devices (CIEDs) can be placed above or below the pectoralis major muscle. When a patient has both devices, knowledge of the pocket location is important for procedural planning and for durability of device placement and performance. Here, we report a patient who previously failed subcutaneous CIED placement due to incision manipulation with prior threatened device exposure requiring plane change to subpectoral pocket. Her course was complicated by submuscular migration of the CIED into her breast implant periprosthetic pocket. With subcutaneous plane change being inadvisable due to patient noncompliance, soft tissue support of subpectoral CIED placement with an acellular biologic matrix (ABM) was performed. Similar to soft tissue support used for breast implants, submuscular CIED neo-pocket creation with ABM was performed with durable CIED device positioning confirmed at 9 months postprocedure.

Comparison of On-Device AI Software Tools

  • Song, Hong-Jong
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.246-251
    • /
    • 2022
  • As the number of data and devices explodes, centralized data processing and AI analysis have limitations due to the load on the network and cloud. On-device AI technology can provide intelligent services without overloading the network and cloud because the device itself performs AI models. Accordingly, the need for on-device AI technology is emerging. Many smartphones are equipped with On-Device AI technology to support the use of related functions. In this paper, we compare software tools that implement On-Device AI.

The Low Power Algorithm of ZigBee Router for Non Beacon Enabled PAN (Non Beacon Enabled PAN 환경에서 ZigBee Router의 저전력 알고리즘)

  • Yoon, Sung-Kun;Park, Su-Jin;Lee, Ho-Eung;Park, Hyun-Ju
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.280-285
    • /
    • 2008
  • ZigBee is Low Power and Low Data Rate Wireless Communication protocol. It apply to much Ubiquitous Sensor Network. ZigBee PAN is two type PAN. One is Beacon Enabled PAN, the other is Non Beacon Enabled PAN. To support Low Power in Non Beacon Enabled PAN, End-Device enter Active status at End-Device's wishing time and send a data. So, Router does not know End-Device sends a data time. To solving this problem, Router must always exist to Active status. In this case, Router receive a power supply always in Non Beacon Enabled PAN. But Router does not receive a power supply always, Router can not normal operation, such as Router use a battery. To solve this problem, Router will be support low power. In this paper, we will present Router's Low Power Algorithm. And we suggest 'PAN Time'. Device use 'PAN Time' for PAN synchronous. Router using Low Power Algorithm can be enter to inactive status. So Non Beacon Enabled PAN of Router support the low power mode Therefore Router does not receive a power supply always, Router can normal operation.

  • PDF

Design of a Novel Gait Rehabilitation Robot with Upper and Lower Limbs Connections (상하지 연동된 새로운 보행재활 로봇의 설계)

  • Yoon, Jung-Won;Novandy, Bondhan;Christi, Christi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.672-678
    • /
    • 2008
  • This paper proposes a new rehabilitation robot with upper and lower limb connections for gait training. As humans change a walking speed, their nervous systems adapt muscle activation patterns to modify arm swing for the appropriate frequency. By analyzing this property, we can find a relation between arm swinging and lower limb motions. Thus, the lower limb motion can be controlled by the arm swing for walking speed adaptation according to a patent's intension. This paper deals with the design aspects of the suggested gait rehabilitation robot, including a trajectory planning and a control strategy. The suggested robot is mainly composed of upper limb and lower limb devices, a body support system. The lower limb device consists of a slider device and two 2-dof footpads to allow walking training at uneven and various terrains. The upper limb device consists of an arm swing handle and switches to use as a user input device for walking. The body support system will partially support a patient's weight to allow the upper limb motions. Finally, we showed simulation results for the designed trajectory and controller using a dynamic simulation tool.

A Study on the Design Improvement to prevent the stoppage phenomenon of Launch Support Device for Self-Propelled Artillery (자주포용 발사지지대의 멈춤현상 방지를 위한 설계개선 연구)

  • Kim, Sung Hoon;Park, Young Min;Noh, Sang Wan;Park, Dae Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.443-450
    • /
    • 2020
  • This paper reports a design improvement study to solve the stoppage phenomenon caused by the launch-support device applied to K105A1. The K105A1 is a weapon system equipped with an old 105 mm towed howitzer in a wheeled vehicle, which provides superior maneuverability compared to track equipment. The launch support device serves to withstand fire impact and load. In this way, this device is fixed firmly to the ground in preparation for the shooting mission and is responsible for the critical performance, such as fixing the position of the vehicle. On the other hand, during the field test, a temporary stoppage of the launch support occurred, which caused a problem of not being fixed to the ground. To solve this problem, the cause of failure was analyzed by a replay test and parts inspection. In addition, the operating concept, method, and design were analyzed to derive the cause and solve the problem by changing the parts design. Finally, the performance and firing missions were performed normally by applying the changed design to K105A1. The performance stability and reliability of the launch support device were confirmed, which are expected to be of great assistance in the development of military equipment in the future.

Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System (이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조)

  • Lee, Dong-Hyup;Lee, Jang-Hoon;Jung, Tae-Eun
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.512-516
    • /
    • 2007
  • A mechanical circulatory support system is a life-saving option for treating acute severe respiratory failure or cardiac failure. There are currently a few types of assist devices and the Twin-Pulse Life Support (T-PLS) system is a kind of pulsatile pump. We report here on three patients with severe life threatening cardiopulmonary dysfunction who had the T-PLS system used as an assist device. The indications for applying the T-PLS system were continuing respiratory or cardiac failure in spite of maximal ventilatory and inotropic support. There were two patients with acute respiratory failure due to infection and one patient with cardiac failure due to acute myocarditis. One respiratory failure patient and one cardiac failure patient survived after applying the T-PLS system for 3 days and 5 days, respectively. The T-PLS system is useful as an assist device and it should be considered before multi-organ failure occurs.

The Innovative Medical Devices Using Big Data and Artificial Intelligence: Focusing on the cases of Korea, the United States, and Europe (빅데이터 및 인공지능을 이용한 혁신의료기기 발전 방향: 한국, 미국, 유럽의 사례중심)

  • Yun Hee Song;Gyu Ha Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.264-274
    • /
    • 2023
  • Purpose: The objective is to extract insights that can contribute to the formulation of harmonized international policies and support measures for innovative medical devices and management systems. This study aims to propose effective strategies for future medical device innovation and healthcare delivery. Results: It investigates technological advancements, regulatory approval systems, insurance policies, and successful commercialization cases in South Korea, the United States, and the European Union. In 2018, the FDA implemented insurance coverage for Software as a Medical Device (SaMD) and recognized insurance coverage for Digital Therapeutics (DTx). Germany is a country that ensures permanent reimbursement for healthcare applications since 2020, making it the first country to provide legal health insurance coverage for fostering a digital ecosystem. Conclusion: The findings of this research highlight the importance of cultivating a supportive regulatory and environmental framework to facilitate the adoption of innovative medical devices. Continuous support for research and development (R&D) efforts by companies, along with the validation of clinical effectiveness, is crucial.

Development of Brace-type Wearable Robot for Lumbar Stabilization (요부 안정화를 위한 복대형 입는 로봇 개발)

  • Joowan Kim;Jaehoon Sim;Keewon Kim;Sungun Chung;Jaeheung Park
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 2023
  • An abdominal brace is a recommended treatment for patients with lumbar spinal disorders. However, due to the nature of the static brace, it uniformly compresses the lumbar region, which can weaken the lumbar muscles or create a psychological dependence that worsens the condition of the spine when worn for an extended period of time. Due to these issues, doctors limit the wearing time when prescribing it to patients. In this paper, we propose a device that can dynamically provide abdominal pressure and support according to the lumbar motion. The proposed device is a wearable robot in the form of a brace, with actuators and a driving unit mounted on the brace. To enhance wearability and reduce the weight of the device, worm gears actuator and a multi-pulley mechanism were adopted. Based on the spinal motion of the wearer measured by the Inertia measurement unit sensors, the drives wire by driving pulley, which provide tension to the multi-pulley mechanism on both sides, dynamically tightening or loosening the device. Finally, the device can dynamically provide abdominal pressure and support. We describe the hardware and system configuration of the device and demonstrate its potential through basic control experiments.