• 제목/요약/키워드: Supply water temperature

검색결과 533건 처리시간 0.028초

뉴로 유전자 결합모형을 이용한 상수도 1일 급수량 예측 (Prediction of Daily Water Supply Using Neuro Genetic Hybrid Model)

  • 이경훈;강일환;문병석;박진금
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.157-164
    • /
    • 2005
  • Existing models that predict of Daily water supply include statistical models and neural network model. The neural network model was more effective than the statistical models. Only neural network model, which predict of Daily water supply, is focused on estimation of the operational control. Neural network model takes long learning time and gets into local minimum. This study proposes Neuro Genetic hybrid model which a combination of genetic algorithm and neural network. Hybrid model makes up for neural network's shortcomings. In this study, the amount of supply, the mean temperature and the population of the area supplied with water are use for neural network's learning patterns for prediction. RMSE(Root Mean Square Error) is used for a MOE(Measure Of Effectiveness). The comparison of the two models showed that the predicting capability of Hybrid model is more effective than that of neural network model. The proposed hybrid model is able to predict of Daily water, thus it can apply real time estimation of operational control of water works and water drain pipes. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 11.81% and the average error was lower than 1.76%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증 (Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater)

  • 안성수;김우현
    • 전자공학회논문지
    • /
    • 제53권11호
    • /
    • pp.151-159
    • /
    • 2016
  • 본 논문에서는 다량의 온수가 필요하지 않는 세면을 목적으로 개발된 세라믹 발열체 기반 비저장식 순간 전기온수기를 제안한다. 입력되는 물을 가열하여 온수로 출수시키는 히팅모듈은 유량센서를 이용하여 입력되는 물을 감지하고 세라믹 히팅 모듈을 동작시킨다. 히팅 모듈 내부는 분당 1.5리터로 입수되는 물의 온도 대비 약 $15^{\circ}C$정도로 가열된 온수로 입수 2초 내에 출수시키기 위해 1 path 유로로 설계하였고 또한 설계의 타당성을 검증하기 위해 히팅모듈 내부 물의 흐름과 온도변화에 대한 열유동해석을 수행하였다. 기본 설계를 기초로 내부에 막대형 세라믹 발열체 1개가 내장된 히팅모듈을 제작하였다. 히팅모듈 제작 후 3단계로 온도 세팅 기능을 가지는 온수기 시제품을 제작하였다. 제작된 시제품을 분당 1.5리터의 물을 공급하는 상수도관에 연결하고 출수되는 물의 온도 및 시간을 측정한 실험에서 물 공급 후 2초 후에 온수기 3단 기준으로 공급되는 물 온도 대비 $18.3^{\circ}C$로 가열된 온수를 출수할 수 있음을 확인하였다. 그리고 대기전력 1w 미만, 순간 전력도 일반가정에서의 허용범위를 넘지 않는다. 성능 측정 결과들을 통해 제안된 비저장식 순간 전기온수기가 겨울철 세면용으로 가정, 고속도로휴게소, 공장 등의 세면대에 적용이 가능함을 확인하였다.

지속가능 온실 냉난방을 위한 강변여과수 취수 및 회수시스템 개발 (Development of Riverbank Filtration Water Supply and Return System for Sustainable Green House Heating and Cooling)

  • 조용;김대근;김형수;문종필
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.20-29
    • /
    • 2012
  • The green house on the waterfront is air-conditioned by a water-source heat pump system with riverbank filtration water. In order to supply riverbank filtration water in alluvium aquifer, the riverbank filtration facility for water intake and recharge, two pumping wells and one recharge well, has been constructed. The research site in Jinju, Korea was chosen as a good site for riverbank filtration water supply by the surface geological survey, electrical resistivity soundings, and borehole surveys. In the results of two boreholes drilling at the site, it was revealed that the groundwater table is about 3 m under the ground, and that the sandy gravel aquifer layer in the thickness of 6.5 m and 3.5 m occurs at 5 m and 7 m in depth below the ground level respectively. To prevent the recharge water from affecting the pumped water which might be used as heat source or sink, the distance between pumping and recharge wells is designed at least 70 m with a quarter of recharged flow rate. It is predicted that the transfer term, the recharge water affects the pumping well, is over 6 months of heating season. Hydrogeological simulation and underground water temperature measurement have been carried out for the pumping and recharge well positions in order to confirm the capability of sustainable green house heating and cooling.

수구동 액체이젝터를 이용한 농산물의 예냉특성에 관한 연구 (A Study on the Precool Characteristics of Agricultural Products Using the Water-driven Ejector)

  • 박영승;이정혜;김호영;김경근
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.45-49
    • /
    • 2001
  • To maintain the freshness of produce, because of stand away between produced and consumer, we need refrigeration system that can supply to consumer at cold chain as soon as gathering. General refrigeration system consist of refrigeration chamber or low temperature store. But the vacuum technology can rapidly refrigeration without refrigerator. This precool system possible to get low precooled temperature, suitable for the fishes, the meat, the vegetables, the fruit etc. Especially get advantage that quality maintain through rapid refrigeration of ferment directly generate heat. Vacuum precool system's principle is that water saturated temperature reduce according to pressure is get to vacuum area, so product temperature reduce as water evaporation at product. In vacuum suction, unit, on early experiment period run the rotary type vacuum pump at purpose pressure, then maintain pressure by water-diven ejector. As the results, cabbage took about 60 minutes to reach from $23.2^{\circ}C$ to $4.5^{\circ}C$at 5mgHg abs.

  • PDF

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

열원 및 공조설비 통합 최적제어기법 구현에 관한 연구 (Real Time Near Optimal Control Application Strategy for Heat Source and HVAC System)

  • 송재엽;안병천;주영덕;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.60-65
    • /
    • 2008
  • The near-optimal control algorithm for central cooling and heating system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled or hot water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling and heating control system.

  • PDF

주거 건물의 복사냉방시스템 적용에 관한 연구 (A Study on the Application of the Radiant Floor Cooling System in Residential Building)

  • 임재한;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구 (An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump)

  • 김지영;백영진;이영수;나호상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF

태양에너지 해수담수화시스템 실증 (Demonstration study on Desalination System using Solar energy)

  • 김정배;주홍진;윤응상;주문창;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.27-33
    • /
    • 2007
  • In this research, to develop the practical application system of fresh water generation system with plate-type fresh water generator using low pressure evaporation method is the main object, and to do that, this study used the evacuated solar collector with operating range of about $50-85^{\circ}C$ as thermal energy source and solar photovoltaic as electric energy source. To achieve that object, this study set up the demo-plant, then estimated and analyzed the usefulness, the safety, and the reliability through pre-tests during short time ahead of the long-time operation. This study showed that the pumps, which are including sea water supply, ejector, hot water supply, and fresh water pumps, were operated one after another. And, the fresh water yield was closely related with the solar irradiance and lower supply temperature of hot water was revealed more reasonable for the solar energy desalination system. That is due to the insufficient area than the solar collector area being required that was estimated through the performance tests of the fresh water generator.