• Title/Summary/Keyword: Supply rate

Search Result 2,631, Processing Time 0.026 seconds

Application of ANFIS for Prediction of Daily Water Supply (상수도 1일 급수량 예측을 위한 ANFIS적용)

  • Rhee, Kyoung-Hoon;Kang, Il-Hwan;Moon, Byoung-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.281-290
    • /
    • 2000
  • This study investigates the prediction of daily water supply, which is a necessary for the efficient management of water distribution system. ANFIS, namely artificial intelligence, is a neural network into which fuzzy information is inputted and then processed. In this study, daily water supply was predicted through an application of network-based fuzzy inference system(ANFIS) for daily water supply prediction. This study was investigated methods for predicting water supply based on data about the amount of water which supplied in Kwangju city. For variables choice, four analyses of input data were conducted: correlation analysis, autocorrelation analysis, partial autocorrelation analysis, and cross-correlation analysis. Input variables were (a) the amount of water supply, (b) the mean temperature, and (c) the population of the area supplied with water. Variables were combined in an integrated model. Data of the amount of daily water supply only was modelled and its validity was verified in the case that the meteorological office of weather forecast is not always reliable. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 18.46% and the average error was lower than 2.36%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

  • PDF

Application of Consignment to Three Stage Supply Chain

  • Ryu, Chungsuk;Hwang, Gyuyoung
    • Journal of Distribution Science
    • /
    • v.16 no.7
    • /
    • pp.35-45
    • /
    • 2018
  • Purpose - The study investigates the impact of consignment on the economic performance in the supply chain with three stages. Through the analysis on distinct forms of consignment application, this study intends to answer to the question of how the consignment should be used in the multi-stage supply chain. Research design, data, and methodology - The proposed mathematical model represents the supply chain system with a manufacturer, a wholesaler, and a retailer. Three different forms of consignment application are considered depending on which stages adapt the consignment, and their system profits are compared with the traditional non-consignment system in numerical examples. Results - The numerical examples show that the serial consignment application performs better than any other forms of consignment as well as the non-consignment system. The additional analysis indicates that the system profit is significantly sensitive to the consignment rate. Conclusions - The outcome of this study implies the potential of consignment to improve the system performance even in the multi-stage supply chain system. Meanwhile, each supply chain member's preference to the specific form of consignment application could be different depending on which stage he has. All the supply chain members should jointly determine the appropriate consignment rates to obtain the best system performance.

Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System (자연순환형 태양열 온수기 축열조의 압력식 설계 개조)

  • Boo, Joon-Hong;Jung, Eui-Guk
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

Thermal Performance of Solar Cooling & Hot-water System According to Control Condition (태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능)

  • Lee, Ho;Joo, Hong-Jin;Kim, Sang-Jin;Kwak, Hee-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

Application of Micro Cross-Flow Turbine to Water Supply System (마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구)

  • Choi Young-Do;Kurokawa Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

Current status of certified board members of the Korean thoracoc and cardiovascular society; a survey for specialist supply/demand and resident training program (대한민국 흉부외과 전문의 활동 현황)

  • Sun, Kyung;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.26 no.1
    • /
    • pp.4-11
    • /
    • 1993
  • The Korean Thoracic and Cardiovascular Surgical Society was founded in 1968. After the first Board Certified Examination in 1972, the Society consists of 592 members including 392 specialists [certified board members] now in 1992. Many of the great advances in cardiothoracic surgery were made by pioneering efforts of these members. The annual increment rate of certified board members in KTCSS [KTCSS Boardmen] was 11.9% which was slight greater than that of doctors [6.6%] and overall specialists [9.9%] in Korea. Their working territories were mainly urban areas [91.9%]. Some states showed regional discrepancy in supply/demand of KTCSS Boardmen. 56.1% of all [73.5% of active members] was working at a larger institute than general hospital. There were 99 institutes [41university hospitals and 58 general hospitals] and 76 private clinics where KTCSS Boardmen were employed, and more than three quarters of those institutes have less than 3 in number of KTCSS Boardmen. The rate of practicing private clinics was declined from over than 50% of the beginning to less than 30% now. We propose this survey for a basic data for specialist supply/demand and resident training program.

  • PDF

Influence of coal and air flow rate distribution on gasification characteristics in 200 t/d scale MHI coal gasifier (200 t/d급 MHI 석탄 가스화기의 석탄 및 공기 배분에 따른 가스화 특성 평가)

  • Doh, Yunyoung;Ye, Insoo;Kim, Bongkeun;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.93-96
    • /
    • 2015
  • Commercial coal gasifiers typically use entrained flow type reactors, but have unique features in terms of reactor shape, gasifying agent, coal feeding type, ash/slag discharge, and reaction stages. The MHI gasifier is characterized as air-blow dry-feed entrained reactor, which incorporates a short combustion stage at the bottom and a tall gasification stage above. This study investigates the flow and reaction characteristics inside a MHI gasifier by using computational fluid dynamics (CFD) in order to understand its design and operation features. For its pilot-scale system at 200 ton/day capacity, the distribution of coal and air supply between the two reaction stages was varied. It was found that the syngas composition and carbon conversion rate were not significantly influenced by the changes in the distribution of coal and air supply. However, the temperature, velocity and flow pattern changed sensitively to the changes in the distribution of coal and air supply. The results suggest that one key factor to determine the operational ranges of coal and air supply would be the temperature and flow pattern along the narrower wall between the two reaction stages.

  • PDF

Pressure restricted water supply method during drought using a computer simulation and daily water supply analysis (시뮬레이션과 1일 급수량 분석을 이용한 갈수기 감압에 의한 제한급수 방법)

  • Nam, Youngwook;Kim, Kyungsu;Hyun, Inhwan;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.335-344
    • /
    • 2020
  • Due to global climate change, mega-droughts have occurred frequently. Since long-term droughts make it difficult to secure the water resources, water supply needs to be restricted in a reasonable manner. In the event of limited water supply, the waterworks need to develop a restricted water supply strategy. This study showed that analyzing daily water supply could be used to respond to the first stage of a drought. According to an analysis of Korea's major water authorities, there was about 7~21% of room for daily minimum water supply in case of a drought. Restricting the water supply by lowering pressure is a good strategy for local water authorities with high water leakage rate since leakage is inversely dependent with pressure. For this method, it is necessary to quantify water deficiency and pressure at each node using a simulation. Since DDA-based software is not possible to predict changes in demand at nodes with pressure reduction, WaterGEMS, a PDA software, was used to quantitatively predict water shortages and pressures at each node. Locations where water is deficient need to install booster pumps or to be dispatched with water tank truck and bottled water. Without these support, lowering pressure could not be an option for water works. This paper suggests a method for waterworks to plan a drought by lowering pressure to restrict water supply using daily water supply analysis and PDA based simulation.

Estimation of irrigation return flow from paddy fields based on the reservoir storage rate

  • An, Hyunuk;Kang, Hansol;Nam, Wonho;Lee, Kwangya
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • This study proposed a simple estimation method for irrigation return flow from paddy fields using the water balance model. The merit of this method is applicability to other paddy fields irrigated from agricultural reservoirs due to the simplicity compared with the previous monitoring based estimation method. It was assumed that the unused amount of irrigation water was the return flow which included the quick and delayed return flows. The amount of irrigation supply from a reservoir was estimated from the reservoir water balance with the storage rate and runoff model. It was also assumed that the infiltration was the main source of the delayed return flow and that the other delayed return flow was neglected. In this study, the amount of reservoir inflow and water demand from paddy field are calculated on a daily basis, and irrigation supply was calculated on 10-day basis, taking into account the uncertainty of the model and the reliability of the data. The regression rate was calculated on a yearly basis, and yearly data was computed by accumulating daily and 10-day data, considering that the recirculating water circulation cycle was relatively long. The proposed method was applied to the paddy blocks of the Jamhong and Seosan agricultural reservoirs and the results were acceptable.

Development of a Continuous Type Brown Rice Conditioning Equipment (연속식 현미 조질기 개발)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.503-510
    • /
    • 2000
  • To improve the milling condition of brown rice a continuous type conditioning equipment was developed. To validate the performance of this machine the experimental operation was done at Sa-cheon RPC(Rice Processing Complex) using short grain rough. The initial moisture contents of brown rice were 15.0∼16.5%(w.b) and the flow rate of brown rice passing through the conditioner were 4,370kg per hour. The moisture content differences of brown rice between conditioned and non-conditioned were showed within 0.5%(w.b) This results means that the water injected to brown rice were absorbed to the surface of brown rice evenly. The moisture contents of conditioned treated milled rice were showed slightly higher than that of non-conditioned ones but it was considered that the conditioning process did not affected the weight increasing of milled rice by water supply. For initial moisture contents of 15.0∼16.5%(wb) brown rice it was found that the proper water supply rate was 0.115(cc-water)/(kg·%-brown rice) and the increments of whole rice were 2.2% compared to the non-conditioned ones. it was considered that the conditioning process did not influenced the whiteness of milled rice because the whiteness differences between conditioned and non-conditioned milled rice were negligible. About 18% of electric power which drives the abrasive type rice milling machine was saved at 0.115(cc-water)/(kg·%-brown rice) of water supply rate.

  • PDF