• Title/Summary/Keyword: Supply Temperature

Search Result 1,811, Processing Time 0.033 seconds

A temperature and supply insensitive CMOS current reference using a square root circuit (제곱근 회로를 이용한 온도와 공급 전압에 둔감한 CMOS 정전류원)

  • 이철희;손영수;박홍준
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.12
    • /
    • pp.37-42
    • /
    • 1997
  • A new temperature and supply-insensitive CMOS current reference circuit was designed and tested. Te temperature insensuitivity was achieved by eliminating the mobility dependence term through the multiplication of two current components, one which is proportional to mobility and the other which is inversely proportional to mobility, by using a newly designed CMOS square root circuit. The CMOS sqare root circuit was derived from its bipolar counterpart by operating the MOS transistors in the subthreshold region. The supply insensitivity was achieved by using an internal voltage generator. Te test chip was designed ans sent out for fabrication by using a 2.mu.m double-poly double-metal n-well CMOS technology. When an external voltage source was used for the square root circuit, the maximum variation and the average temperature sensitivity were measured to be 3% and 21.4ppm/.deg.C, respectively, for the temperature range of -15~130.deg.C. The maximum current variation with supply voltage was measured to be 3% within the commerical supply voltage range of 4.5~5.5V at 30.deg. C.

  • PDF

The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature (외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Cho, Young-Don;Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Characteristics of Fluid Supply in Discontinuous Wheel Grinding (단속연삭의 유제공급 특성)

  • Kwak, Yong-Gil;Hong, Sun-Ik;Song, Ji-Bok;Koo, Yang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.857-861
    • /
    • 1997
  • In discontinuous wheel grinding, temperature is different form conventional grinding. The characteristics of discontinuous grinding with respect to various slotted wheel were compared with those of general grinding. Thermal conditions vary with intermittent ratio, direction of fluid supply for discontinous wheel. According to three direction of grinding fluid supply and intermittent ratio,temperature and surface roughness were analyzed.

  • PDF

The Seasonal Variation of Free Chlorine Residuals by Water Supply Distance in Daegu (대구 지역의 계절 변화에 따른 급수관내 잔류염소 농도 거동)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2005
  • This paper presents the integrated technique of water quality analysis and Geographic Information System(GIS) for assessing the variation of free chlorine residuals by water temperature and supply distance in Sangri water supply system in Daegu. GIS was utilized for mapping projectmap, extraction of a pipeline route, and supply distance. Free chlorine residual is analyzed every month for appraising the seasonal variation. As a result, free chlorine residuals are affected both water temperature and water supply distance, and it becomes worse as water temperature and water supply distance is increased. To maintain 0.4mg/l of free chlorine residual, initial dose concentration should be over 1.85mg/l in summer.

The Changes of Temperature for Embedded Duct Ventilation System in Ondol (바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰)

  • Kim, Ok;Park, Jin-Chul;Kim, Nam-Gyu;Oh, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

The Effect of Oil-Starvation on the Lubrication Characteristics of High-Speed Bearing: Part II-Roller Bearing (가스터어빈용 고속 베어링의 Oil-Starvation 윤활특성: Part II-Roller Bearing)

  • Kim, Ki-Tae
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.76-81
    • /
    • 1997
  • The lubrication characteristics of high-speed roller bearings at oil-starvation have been investigated empirically using the bearings employed in small industrial gas turbine engines. Testing was done by simulating the oil-starvation conditions in engines, such as stopping the oil-supply to the bearing during normal operating, starting without oil-supply at atmospheric temperature, and accelerating with oil-supply at atmospheric temperature. During testing, the temperature of bearing, the power consumption, and the rotating resistance of the bearing were measured. From this study, on the contrary to the ball bearing, it was found that the resistance of the bearing was higher at the regime of without oil-supply than that at the regime of with oil-supply, despite less power consumption.

Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter (인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교)

  • Cho, Sung-Hwan;Hong, Seong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.