• 제목/요약/키워드: Supply Air Temperature

검색결과 475건 처리시간 0.023초

MATLAB/Simulink를 이용한 자동차용 상압형 PEM 연료전지 시스템의 성능 및 효율 분석 연구 (A Study on the Analysis of the Performance and Efficiency of a Low-pressure Operating PEMFC System for Vehicle Applications Using MATLAB/Simulink)

  • 박래혁;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.393-400
    • /
    • 2013
  • The air supply system has a significant effect on the efficiency of polymer electrolyte membrane fuel cell (PEMFC) systems. The performance and efficiency of automotive PEMFC systems are greatly influenced by their air supply system configurations. This study deals with the system simulation of automotive PEMFC systems using MATLAB/Simulink framework. In this study, a low-pressure operating PEMFC system adopting blower sub-module (turbo-blower) is modeled to investigate the effects of stack operating temperature and air stoichiometry on the parasitic power and efficiency of automotive PEMFC systems. In addition, the PEMFC net system efficiency and parasitic power of air supply system are mainly compared for the two types (low-pressure operating and high-pressure operating) of automotive PEMFC systems under the same net power conditions. It is suggested that the obtained results from this system approach can be applied for establishing the novel operating strategies for FC vehicles.

미분탄 보일러의 연소용 공기공급 변화에 따른 노내 연소상태 해석 (Combustion Characteristics of Coal-Fired Boiler Depending on the Variations in Combustion Air Supply Method)

  • 서상일;박호영;강동수;정동해
    • 에너지공학
    • /
    • 제19권3호
    • /
    • pp.156-162
    • /
    • 2010
  • 국내 미분탄 보일러의 로내 공기량 공급에 따른 연소특성 분석을 위한 3차원 전산해석 연구를 수행하였다. 보일러 연소해석 해석 결과의 건전성 검증을 위하여 보일러 출구, 즉 절탄기 후단에서의 가스 온도,$O_2$, NO, SOx 농도를 발전소의 실제 운전데이터와 비교하였다. 검증된 해석 결과를 기준조건으로 SOFA(Separated Over Fire Air)와 CCOFA(Closed Coupled Over Fire Air)에서의 연소 공기량을 변화시킨 경우 보일러내 NOx와 가스 온도 분포를 중심으로 각각의 경우를 비교하였다. 본 연구를 통하여 CCOFA보다는 SOFA 공기량의 변화에 따라 NOx 농도의 민감도가 더 큰 것을 알 수 있었으며 대류 전열부의 전열관군에서의 온도 분포가 다르게 나타나고 있어 가스온도 편차 방지를 위한 연소조정이 필요함을 알 수 있었다.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

공기실이 설치된 건축물 급수관로의 과도압력 특성 (Characteristics of the Transient Pressure in a Building Water Supply System with an Air Chamber)

  • 황희성;임기원;이광복;조병선;차동진
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.782-790
    • /
    • 2000
  • A numerical study has been conducted to characterize the transient pressure in a building water supply system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for the purpose of verification in the study agree quite well with the previously reported. Several parameters are then varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the inner diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^P{circ}C $,/TEX> and 0.8 m/s, respectively, Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

코안다 노즐을 이용한 배기가스 재순환 장치의 형상에 따른 재순환 유동 특성에 관한 연구 (A Study on the Recirculation Flow Characteristics with the Change of Shape in a Flue Gas Recirculation Device using Coanda Nozzle)

  • 하지수;심성훈;김대연
    • 한국가스학회지
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 2019
  • 본 연구는 폐기물 소각로에서 질소산화물 저감을 위해 고온의 배기가스를 연소로에서 재순환하여 연소용 공기와 혼합하여 배기가스 재순환을 이용한 방법에서 고온의 배기가스를 별도의 동력 팬이 없이 코안다 노즐을 이용한 배기가스 재순환 장치에 관한 연구이다. 코안다 노즐에서 공기 공급 노즐 간극의 변화와 공기 공급 노즐의 위치에 따른 배기가스 재순환 유량 특성과 혼합 가스의 출구에서 평균온도 변화를 살펴보았다. 공기 공급 노즐의 간극이 3.22, 4.03, 4.84 mm로 변할 때 가장 좁은 3.22 mm일 때가 배기가스 재순환 유량과 공기 공급 유량의 비인 배기가스 재순환 유량비가 2.227로 가장 재순환 유량이 크게 나타났고 혼합가스 평균 온도는 $594.8^{\circ}C$로 나타났다. 공기 공급 노즐의 위치가 코안다 노즐 목의 전방 위치, 목 위치, 확관 위치로 변할 때를 살펴보았으며 전방 위치와 목 위치일 때는 재순환 유량비가 1.843으로 거의 같은 값이고 확관 위치에서는 1.696으로 나타났으며 평균 온도는 $559.8^{\circ}C$$544.3^{\circ}C$로 나타났다.

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

The Characteristics of Pulverized Coal Combustion in the Two Stage Cyclone Combustor

  • Joo, Nahm-Roh;Kim, Ho-Young;Chung, Jin-Taek;Park, Sang-Il
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1112-1120
    • /
    • 2002
  • Numerical investigations on air staging and fuel staging were carried out with a newly designed coaxial cyclone combustor, which uses the method of two stage coal combustion composed of pre-combustor and main combustor. The pre-combustor with a high air/fuel ratio is designed to supply gas at high temperature to the main combustor. To avoid local high temperature region in this process, secondary air is injected in the downstream. Together with the burned gas supplied from the pre-combustor and the preheated air directly injected into main combustor, coals supplied through the main burner react rapidly at a low air/fuel ratio. Strong swirling motion of cyclone combustor keeps the wall temperature high, which makes slagging combustion possible. Alaska, US coal is used for calculations. Predictions were made for various coal flow rates in the main combustor for fuel staging and for the various flow rate of secondary air in the pre-combustor for air staging. In-scattering angles are also chosen as a variable to increase residence times of coal particles. Temperature fields and particle trajectories for various conditions are described. Predicted temperature variations at the wall of the combustor are compared with corresponding experimental data and show a similar trend. The in-scattering angle of 20° is recommended to increase the combustion efficiency in the main chamber.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

성주지역 참외전용 온실의 모델개발 및 환경분석(1) -성주 시설 참외단지 단동하우스의 온도 분포 특성- (Modelling Development and Environmental Analysis of Oriental Melon Greenhouse in SUNGJU(1) -Characteristics on distribution of air temperature for cultivating oriental melon in tunnel type greenhouse in Sungiu-)

  • 송재관;박규식;구건효
    • 생물환경조절학회지
    • /
    • 제7권4호
    • /
    • pp.311-323
    • /
    • 1998
  • 현재 경북지방의 수박 및 참외재배에 가장 많이 이용되고 있는 대형터널 하우스의 온도 변화를 분석한 결과, 터널하우스 내 기온은 일몰과 함께 강하하여 외기온과 비슷한 온도를 유지하는 시간은 일몰 후 약 2시간 30분 전후로 나타났으며, 자연환기장치인 환기공 및 수동식 측창이 설치되어 재배기간중 하우스내 최고기온은 4$0^{\circ}C$ 이상 유지되지는 않았다. 하우스야간온도는 높이별 위치에 관계없이 거의 같은 온도로 유지되었으며, 재배기간중 야간온도는 외기온보다 2~3$^{\circ}C$정도 높게 유지할 수 있었지만, 외기온이 적온 이하일 때는 보온의 필요성이 있었다. 또 재배기간중 20cm 깊이의 지온은 2$0^{\circ}C$ 이상을 유지할 수 있어서 적정지온 확보에는 문제가 없었으며, 일변동폭은 3~5$^{\circ}C$ 정도이고 관수로 인한 지온저하는 5~6$^{\circ}C$ 정도였다

  • PDF

산란계에 적용 가능한 공기-물 히트펌프의 음용수 공급시스템 이용기술에 관한 연구 (Study on the Utilization of Drinking Water Supply System of Air-water Heat Pumps Applicable to Laying Hen)

  • 백이;강석원;장재경;권진경
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.917-923
    • /
    • 2018
  • The drinking water supply system applicable to the laying hen consists of air-water heat pumps, drinking water tanks, heat stroage tank, circulation pumps, PE pipes, nipples, and control panels. When the heat pump system has power of 7.7 to 8.7 kW per hour, the performance coefficient is between 3.1 and 3.5. The supply temperature from the heat pump to the heat stroage tank was stabilized at about $12{\pm}1^{\circ}C$, but the return temperature showed a variation of from 8 to $14^{\circ}C$. Stratified temperature in the storage tank appeared at $12.^{\circ}C$, $13.5^{\circ}C$ and $14.4^{\circ}C$, respectively. The drinking water supply temperature remained set at $15^{\circ}C$ and $25^{\circ}C$, and the conventional tap water showed a variation for $23^{\circ}C$ to $30^{\circ}C$. As chickens grow older, the amount of food intake and drinking water increased. $y=-0.0563x^2+4.7383x+8.743$, $R^2=0.98$ and the feed intake showed $y=-0.1013x^2+8.5611x$. In the future, further studies will need to figure out the cooling effect on heat stress of livestock.