• 제목/요약/키워드: Supply Air Temperature

검색결과 475건 처리시간 0.028초

외기온도와 환수온도를 이용한 보일러의 공급수온도설정 (Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature)

  • 한도영;유병강
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF

핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger)

  • 최권삼
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

FUZZY PID 방법을 이용한 개별 공조시스템의 급기온도 제어 (A FUZZY PID Control of Supply Duct Outlet Air Temperature for PEM)

  • 장영준;박영철;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.278-284
    • /
    • 2002
  • The work presented here provides a control of the supply duct outlet air temperature in PEM (personal environment module) using fuzzy PID controller. In previous work, PID control systems were used, but the result shows that the outlet air temperature and electric heater regulating voltage were oscillated. Fuzzy PID control systems are designed to improve the system response obtained using PID control and implemented experimentally Also, PID controller and fuzzy controller without PID logic are provided to compare the result with that of the fuzzy PID controller. Data obtained shows that the fuzzy PID control system satisfies the design criteria and works proper1y in controlling the supply air temperature. Also it has bettor performance than the previous result obtained using PID control.

개별공조시스템을 위한 전기히터의 PID 제어 (A PID Control of Electric Heater for PEM)

  • 장영준;박영칠;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF

멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구 (A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

돔경기장의 급배기방식에 따른 기류분포 및 실내온도 특성 (The Characteristics of Indoor Temperature and Airflow Distribution for Air Supply and Return System in Dome Stadium)

  • 채문병;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.434-439
    • /
    • 2008
  • Dome stadiums give thermal unpleasant feeling to occupants because of the radiant heat and the indoor and outdoor haet exchange from roogs or lightweight building envelopes of sidewalls. This study analyzed the indoor temperature and velocity distribution according to various air supply and return sustems in dome stadiums in summer.

  • PDF

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

상업용 주방후드의 배기성능 개선방안에 관한 연구 (A Study on the Improvement Strategies for Exhaust Performance in Commercial Kitchen Hoods)

  • 박진철
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.439-445
    • /
    • 2003
  • The purpose of this study is to suggest the improvement strategies for exhaust performance in composite kitchen hoods. The Exhaust only hood, the 2-way compensating hood and the 3-way compensating hood were selected, and the laboratory experiments were performed to compare the local exhaust efficiency and the indoor temperature distributions according to the variations of the hood type and supply/exhaust air velocity. The results of this study can be summarized as follows. The compensating hood has better performance than exhaust only hood in the aspect of local exhaust efficiency and temperature distribution. The 3-way compensating hood shows the best performance when the supply air velocity is about 2.7 m/s, and the 2-way compensating hood at the supply air velocity of 3.5 w/s. In the same exhaust rate condition, if the exhaust area of the hood is increased and therefore the exhaust velocity is lowered, the supply air velocity is also lowered to get the optimum performance. The optimum exhaust velocity range of the commercial kitchen hood which derived from this study is 0.48 ∼ 0.55 m/s.

초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정 (Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF