• Title/Summary/Keyword: Supine

Search Result 466, Processing Time 0.029 seconds

A Comparative Study and Measurement of R.O.M. in the Hip joint of Korean's (한국인의 고관절 회전 가동 범위의 측정 및 비교 고찰)

  • Park, Hung-Ki;Kim, Keun-Jo;Ju, Mu-Yeol
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.39-52
    • /
    • 2003
  • The test for internal and external rotation of hip joint, was donet from September 2 to 9, 2002, with the participation of 50 male/female university students who are in a normal health condition. Results are : 1. When applying the external rotation of 45 degrees angle ; 1) In a sitting position, for male it results in an increase of 5 degrees on right and left sides each. 2) In a sitting position, for female there is no change on both right and left sides. 3) In a supine position, for both male and female it results in an increase of 5 to 10 degrees on right and left sides each. 4) In a prone position, for male it results in an increase of 5 degrees on the left side only. 5) In a prone position, for female it results in an increase of 5 to 10 degrees on right and left sides each. 2. When applying the internal rotation of 45 degrees angle ; 1) In a sitting position, for male it results in a decrease of 5 degrees on right and left sides each. 2) In a sitting position, for female there is no change on both right and left sides. 3) In a supine and prone position, there is no change for male. 4) In a supine position, for female it results in an increase of 5 to 10 degrees on right and left sides each. 5) In a prone position, for female it results in an increase of 5 degrees on right and left sides each.

  • PDF

Physiological and Psychological Effects of Vibroacoustic Stimulation to Scapular and Sacrum of Supine Position

  • Lim, Seung Yeop;Heo, Hyun;Kim, Sang Ho;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.345-353
    • /
    • 2013
  • Objective: This research measured physiological and psychological effects of Vibroacoustic stimulation(VA) to scapular and sacrum of supine position on the mattress. Background: When vibroacoustic stimulation applies to human body, it has a positive influence on physiological and psychological effects by stimulating the organs, tissues and cells of whole body. Method: This experiment was conducted to 10 normal males in two conditions: no stimulation and vibroacoustic stimulation. No stimulation experiment was executed as a supine position for 30 minutes without any vibrational stimulus, while vibroacoustic stimulation was transmitted by the vibrational speaker, which uses 40Hz frequency. Subjects had a laser Doppler flowmeter probe in scapular, sacrum, and also had 8 channel electroencephalogram(EEG) measurement sensor in the scalp. Blood pressure and skin temperature were measured in two conditions with an underlying posture for 30 minutes. Additionally, blood flow rate and EEG were measured before and after for two minutes on two conditions. Results: According to the vibroacoustic stimulation, blood flow rate and skin temperature were increased, while blood pressure was decreased. When using vibroacoustic stimulation compared to no stimulation, blood flow rate went approximately two times higher, and skin temperature also higher 3~4 times. Furthermore, the relative alpha power of brain wave was significantly increased when we applied to vibroacoustic stimulation. Conclusion: This experiment tested the VAT embedded in mattress in two conditions. According to this experiment, VAT decreases blood pressure, improves not only a physiological effect on blood flow rate as well as skin temperature, but also psychological functions by increasing relative alpha power. Application: The results of the publishing trend analysis might help physiological and psychological effects of vibroacoustic stimulation.

An Experimental Study on the Effects of Nursing Care According to Change of Position During Labor (분만과정중 산모 체위변경에 따른 간호효과의 실질적 연구)

  • 조원분
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.139-151
    • /
    • 1978
  • This study is to observe the effects of nursing care according to change of position for comfort during labor and safe delivery of newborn infants and perturbment women. Fifty antepartal primipara with labor pain who were admitted to the delivery room of H University Medical Center from September 1, 1976 to November 15, 1976 (Estimate Delivery Confinement) were selected for this investigation. Among the 50 parturiencys, the experimental group (28 primipara) were placed in 30 degree upright sitting position and the control group (22 primipara) were placed in the supine position. following placement, both groups were observed. The summarized findings of the study were as follows; 1. There was a noticeably significant difference in the duration of the first stage of labor (defined as 4 cm. dilatation of the cervical os with the fetal presenting part engaged to full or 10 cm. dilatation) , between the two groups. For women in the 30 degree upright sitting position, the first stage of labor was close to 33.66 minutes shorter. than for the women in the supine position. (t : 32.79, D.F : 48, p<0.0,i) 2. Although slight differences were observed between the Apgar Scores of the newborn infants of primipara in the two groups, these were not significant. The mean Apgar Score among the newborn infants of primipara in the 30 degree upright sitting position was 9.64 compared with 9.04 for the newborn infants of primipara in the supine position, a difference of 0.6. (x$^2$= 2.44, D.F : 2, p〉0.05) 3. There was a significant difference in the conformability of the perturbment women between the two groups because the shortened duration of the first stage and the high level of comfort score calculated for six factors (body activity, serving bed pan, serving kidney basin, pushing, deep breathing and perturbment women's feelings), that affect nursing care.

  • PDF

Electromyographic Activation of Lumbar Multifidus Muscle Induced by Horizontal Shoulder Extension Exercise: Comparison of Four Intensity Levels of the Exercise (등척성 견관절 수평 신전 운동의 강도에 따른 다열근의 활성도 비교)

  • Bang, Yun-Kyung;Yoon, Dong-Joon;Yoon, Hee-Yeon;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.9-19
    • /
    • 2010
  • Purpose : To identify whether isometric shoulder horizontal extension (ISHE) exercise could sufficiently activate the lumbar multifidus muscle, and to determine appropriate exercise intensity to increase muscle strength. Methods : Twenty healthy volunteers (10 males and 10 females) participated in this study. ISHE exercises on the dominant side were performed with $90^{\circ}$ shoulder abduction held in $90^{\circ}$ elbow flexion so that their arms were in the horizontal plane. Electromyographic (EMG) measurements of multifidus activation were performed in standing and supine positions, and were taken under four strength conditions: 75%, 50% and 25% of maximum shoulder horizontal extension strength, and maximum strength. Results : The EMG activations of both lumbar multifidus increased significantly with ISHE exercises of larger % strength (p<.05). In their multifidus EMG data measured in standing and supine positions, men differed significantly in their 75%, 50% and 25% strength for both sides (p<.05), and women differed significantly in their 75%, 50% and 25% strength on their 5th lumbar vertebrae's left side, but 75% only for their 5th lumbar vertebrae's right side (p<.05). The EMG data of 5th lumbar vertebrae's left and 5th lumbar vertebrae's right sides appeared to differ significantly at all strength levels for men while standing, but only at the 25% level for women in the supine position (p<.05). These findings indicate that ISHE exercises can be considered a beneficial method to enhance the multifidus strength. Conclusion : This study provides useful information for further study in this field.

  • PDF

Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs

  • Kim, Seong Hwan;Park, Yong-Beom;Song, Min-Ku;Lim, Jung-Won;Lee, Han-Jun
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: To evaluate the reliability and validity of the femorotibial mechanical axis angle from radiographs in the weight bearing (WB) and supine positions compared with navigation-measured values. Materials and Methods: Sixty-eight cases of navigation-assisted total knee arthroplasty (TKA) were included. The pre- and postoperative whole leg radiographs (WLRs) in WB and supine positions were compared with the initial and final navigation values. Results: The mean mechanical axis angle from the preoperative WBWLR and navigation were not statistically different (p=0.079) and were correlated strongly with each other (intraclass correlation [ICC], 0.818). However, on postoperative measurements, although the WBWLR and navigation values were not different (p=0.098), they were not correlated with each other (ICC, 0.093). The standard error of measurement was $1.8^{\circ}{\pm}3.6^{\circ}$ for the preoperative WBWLR and $2.5^{\circ}{\pm}4.8^{\circ}$ for the postoperative WBWLR. The validity that was determined by the Bland-Altman plot was not acceptable for both pre- and postoperative measurements. Conclusions: The preoperative WBWLR could provide accurate but not precise measurement value of the femorotibial mechanical axis angle for navigation-assisted TKA, and postoperative measurements in navigation were not comparable with radiographic measurements. The lack of agreement was found between the radiographic and navigation measurements of the coronal alignment regardless of pre- or postoperative evaluation although the accuracy was found acceptable. Level of Evidence : Level 4.

The Effects of Plank Exercises with the Contraction of the Adductor Muscle of the Hip Joint on Core Muscle Thickness (엉덩관절 모음근의 수축을 동반한 플랭크 운동이 중심 근육의 두께에 미치는 영향)

  • Ko, Min-Gyun;Song, Chang-Ho
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.293-302
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of plank exercises involving the contraction of the adductor muscle of the hip joint on core muscle thickness and to propose an effective plank exercise method. Methods: A total of 30 healthy young adults (17 males, 13 females) voluntarily participated in the study. The subjects were randomized to the prone plank exercise with hip adductor contraction (n=10), the prone plank exercise (n=10), and the supine plank exercise (n=10) groups. Muscle thickness measurements were taken prior to starting the exercise program and after completing the program at the end of a 4-week period. The muscle thickness of the rectus abdominis (RA), multifidus (MF), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) muscles were measured using ultrasonography. Each group performed the stipulated plank exercise five times a week as follows: 5 sets of 20 seconds during the first week, 5 sets of 30 seconds in the second week, 5 sets of 40 seconds in the third week, and 5 sets of 40 seconds in the last week. Results: The three different types of plank exercises all showed significantly increased thickness of the RA, MF, EO, IO, and TrA (P<0.05). Furthermore, changes in the thickness of both the MF and TrA were statistically more significant in the groups that did the prone plank exercise with the hip adductor contraction and the supine plank exercise than in the prone plank exercise group (P<0.05). Conclusion: The study results suggest that the prone plank exercise with hip adductor contraction is a more effective method for overall activation of the RA, MF, EO, IO, and TrA than the prone plank exercise and the supine plank exercise.

Correlational Analysis of Supine Position Time and Sleep-related Variables in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡 증후군에서 앙와위 자세시간과 수면관련변인 간 상관관계 분석)

  • Kim, Si Young;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Objectives: A supine sleep position increases sleep apneas compared to non-supine positions in obstructive sleep apnea syndrome (OSAS). However, supine position time (SPT) is not highly associated with apnea-hypopnea index (AHI) in OSAS. We evaluated the correlation among sleep-related variables and SPT in OSAS. Methods: A total of 365 men with OSAS were enrolled in this study. We analyzed how SPT was correlated with demographic data, sleep structure-related variables, OSAS-related variables and heart rate variability (HRV). Multiple linear regression analysis was conducted to investigate the factors that affected SPT. Results: SPT had the most significant correlation with total sleep time (TST ; r = 0.443, p < 0.001), followed by sleep efficiency (SE ; r = 0.300, p < 0.001). Snoring time (r = 0.238, p < 0.001), time at < 90% SpO2 (r = 0.188, p < 0.001), apnea-hypopnea index (AHI ; r = 0.180, p = 0.001) and oxygen desaturation index (ODI ; r = 0.149, p = 0.004) were significantly correlated with SPT. Multiple regression analysis revealed that TST (t = 7.781, p < 0.001), snoring time (t = 3.794, p < 0.001), AHI (t = 3.768, p < 0.001) and NN50 count (t = 1.993, p = 0.047) were associated with SPT. Conclusion: SPT was more highly associated with sleep structure-related parameters than OSAS-related variables. SPT was correlated with TST, SE, AHI, snoring time and NN50 count. This suggests that SPT is likely to be determined by sleep structure, HRV and the severity of OSAS.

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

The Image Distortion Analysis of Levin-tube tip by Patient position and Incidence Angle when taking Mobile Chest AP Projection (Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석)

  • Lee, Jinsoo;Park, Hyonghu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.467-471
    • /
    • 2015
  • This study's purpose is improve image quality to keep accurate tube angle in order to recognize distortion degree conditions by patient's position or tube angle and to provide exact clinical informations when taking chest AP projection for patient which have L-tube in stomach. The experimental equipment was ELMO-T6S by SHIMADZU corporation, then we put L-tube which attached 1 mm gap scales ruler on chest phantom surface. The experiment set by 90 kVp, 4 mAs, 120 cm distance. Each phantom position which changed supine, 30degree, 45degree, 60degree on the table exposured direct, ${\pm}5degree$, ${\pm}10degree$, ${\pm}15degree$ to head and feet directions. As a result, L-tube tip's position was changed by patient's position and tube angle. When patient's position is supine, tip's position change was lower than 30degree, 45degree, 60degree. We have to adjust patient's position or tube angle in order to occur image distortion by fault tube angle when confirming correct position L-tube tip through chest x-ray. Also, Radiological technologist try to make accurate evaluation index for satisfied L-tube insertion.