• Title/Summary/Keyword: Supervisory control system

Search Result 262, Processing Time 0.024 seconds

A Development of Cipher Device based on Embedded Linux for Serial Communication in SCADA (임베디드 리눅스 기반의 SCADA 직렬통신 구간 암호화 장치 개발)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.25-32
    • /
    • 2010
  • The Supervisory Control and Data Acquisition Systems (SCADA) system provides monitoring, data gathering, analysis, and control of the equipment used to manage most infrastructure. The SCADA Network is implemented in a various manner for larger utilities, and multiple types of protocol and communication interfaces are used to network the control center to remote sites. The existing SCADA equipment and protocols were designed and implemented with availability and efficiency, and as a result security was not a consideration. So, performance, reliability, flexibility and safety of SCADA systems are robust, while the security of these systems is often weak. This makes some SCADA networks potentially vulnerable to disruption of service, process redirection, or manipulation of operational data that could result in public safety concerns and/or serious disruptions to the infrastructure. To reduce the risks, therefore, there is a need to have a security device such as cipher devices or cryptographic modules for security solutions. In this paper we develop an embedded cipher device for the SCADA equipment. This paper presents a cipher device designed to improve the security of its networks, especially in the serial communication.

Korean Style System Model of Financial ADR (한국형 금융ADR의 제도모델)

  • Seo, Hee-Sok
    • Journal of Legislation Research
    • /
    • no.44
    • /
    • pp.343-386
    • /
    • 2013
  • "Financial ADR" system in South Korea can be represented by so-called "Financial Dispute Resolution System", in which Financial Supervisory Service (FSS) and Financial Dispute Resolution Committee are the principal actors in operation of the system, and this is discussed as an "Administrative Financial ADR System". The system has over 10-year history since it was introduced in around 1999. Nonetheless, it was not until when financial consumer protection began to be highlighted after the 2008 financial crisis that Financial ADR system actually started to draw attention in Korea. This was because interest has been rising in "Alternative Dispute Resolution (ADR)" as an institutional measure to protect financial consumers damaged via financial transactions. However, the current discussion on the domestic Financial ADR system shows an aspect that it is confined to who is to be a principal actor for the operation of Financial ADR institution with main regards to reorganization of supervisory system. This article aims to embody these facts in an institutional model by recognizing them as a problem and analyzing the features of the Financial ADR system, thereby clarifying problems of the system and presenting the direction of improvement. The Korean Financial ADR system can be judged as "administrative model integrated model consensual model quasi-judicial model non-prepositive Internal Dispute Resolution (IDR) model". However, at the same time, it is confronted with a task to overcome the two problems; the system is not equipped with institutional basis for securing its validity in spite of the adopted quasi-judicial effect model; and a burden of operating an integrated ADR system is considerable. From this perspective, the article suggests improvement plans for security of validity in the current system and for expansion of industry-control ADR system, in particular, a system of prepositive IDR model. Amongst them, it suggests further plans for securing the validity of the system as follows; promotion to expand the number of internal persons and to differentiate mediation procedures and effect; a plan to keep a financial institution from filing a lawsuit before an agreement recommendation or a mediation proposal is advised; and a plan to grant suspension of extinctive prescription as well as that of procedures of the lawsuit.

Protocol converting method for the Real-time Safety Supervision System in Railway (실시간 철도안전 관제를 위한 프로토콜 변환 방안 연구)

  • Ahn, Jin;Kim, Sung-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1335-1341
    • /
    • 2016
  • For the safety of train operation, monitoring & supervisory systems for train, signal, power, communication and facilities is operating independently in another place, so, its sensors are interdependently connected from each other to transfer gathering datas of sensing to control center. A Goal of Real-time railway safety supervision system is to improve the safety oversight efficiency and to prevent accidents by means of hazard prediction based on big data by integrating all of safety sensing data in wayside of railway, and the System is requested acquisition of all of sensing data of safety. So, we need special method of protocol converting for the purpose of integrating all of detecting data concerning safety without any changing application. In this paper we investigate the existing converting method in communication field, and propose a new progress to converting protocol adding function of transfer using XML file, and implemented this algorithm, and tested with example packets, finally.

Condition Assessment for Wind Turbines with Doubly Fed Induction Generators Based on SCADA Data

  • Sun, Peng;Li, Jian;Wang, Caisheng;Yan, Yonglong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.689-700
    • /
    • 2017
  • This paper presents an effective approach for wind turbine (WT) condition assessment based on the data collected from wind farm supervisory control and data acquisition (SCADA) system. Three types of assessment indices are determined based on the monitoring parameters obtained from the SCADA system. Neural Networks (NNs) are used to establish prediction models for the assessment indices that are dependent on environmental conditions such as ambient temperature and wind speed. An abnormal level index (ALI) is defined to quantify the abnormal level of the proposed indices. Prediction errors of the prediction models follow a normal distribution. Thus, the ALIs can be calculated based on the probability density function of normal distribution. For other assessment indices, the ALIs are calculated by the nonparametric estimation based cumulative probability density function. A Back-Propagation NN (BPNN) algorithm is used for the overall WT condition assessment. The inputs to the BPNN are the ALIs of the proposed indices. The network structure and the number of nodes in the hidden layer are carefully chosen when the BPNN model is being trained. The condition assessment method has been used for real 1.5 MW WTs with doubly fed induction generators. Results show that the proposed assessment method could effectively predict the change of operating conditions prior to fault occurrences and provide early alarming of the developing faults of WTs.

Conceptual Development of the Plant Operations Regulator for Nuclear Power Plant Operating Flexibility (원전 운전 유연성 향상을 위한 운전 조정기 개념의 개발)

  • Park, Jung-In;Lee, Myeong-Hoon;Song, In-Ho;Oh, Soo-Youl;Hah, Yung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.285-296
    • /
    • 1992
  • The conceptual design of the Plant Operations Regulator (POR) is presented for the pressurized water reactor plants. The POR is a digital supervisory limitation control system The POR assures that the plant does not exceed the operating limits by regulating the plant operations through monitoring the operating margins of the critical parameters. The POR is aimed at increasing the operating flexibility which allows the nuclear plant to meet the grid demand in very efficient manner. It responds to the grid demand without penalizing plant availability by limiting the load demand or by modifying the plant control schemes when the operating limits are approached or violated. The POR design concepts were tested using simulation responses of the 1000 MWe pressurized water reactors, Yonggwang Units 3 & 4. The simulation results illustrate that the POR can be used to improve operating flexibility.

  • PDF

A Study on the Interface between DAS and SCADA by using Direct Method (직접연계방법에 의한 DAS-SCADA 연계 연구)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1154-1163
    • /
    • 2008
  • DAS and SCADA system are main systems, which operate and manage the power system by using computer and communication technology. But DAS and SCADA have been operated independently in Korea, so there was some time delay in the fault handling and live-line work. To improve that problems, studies on the interface between DAS and SCADA have been needed. From November 2005 to December 2007, the pilot project has been performed in KEPCO's branch offices, as a result, direct method will be applied widely all over the country until 2010 because the operation information of substation users want can be transmitted fast and it is possible to control 43RC directly although the expense for direct method is about 1.3 times larger than that for web method. To improve problems revealed during the pilot project, substation object to object communication method is proposed and interface database automatic generation and interface system diagnosis and logging functions are developed. Interface data point and communication data type are defined, substation single line diagram automatic generation or manual editing function, SCADA monitoring and controlling function, log data managing function are developed in SCADA HMI program. It is expecting to reduce the average time for each outage about 33% and to improve the reliability, efficiency of operation, execution of DAS from automatic load transfer under a fault, and to contribute to export project.

A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language (언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교)

  • Noh, Bokyung;Ban, Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • This research is about alternative measure of main components for sprinkler system like automatic wet pipe sprinkler system, dry pipe sprinkler system, pre-action sprinkler system, vacuum sprinkler system, deluge sprinkler system, and so on. By replacing the alarm check valve, dry valve, pre-operated valve, and deluge open valve with a solenoid valve, it be can be simplifed the various processes of the manufacturing process into one process, it creates an environment in which one standardized product can be produced simultaneously on a single machine. Therefore, it could improve the price competitiveness of products, reduce the maintenance cost, and help the adaptability of new sprinkler systems in the future. There is a benefit when it comes to apply to sprinkler system. Only replace the valve which is used to control primary and secondary valve such as wet, dry, pre operated, vacuum, deluge system valve. Other components such as retarding chambers, automatic air compressors, accelerators or adjusters, supervisory panels, vacuum pumps, and manual starters can be used as they are, so they can be easily applied to existing sprinkler system. It is needed to legal and institutional study for solenoid valve applied sprinkler system to commercialize.

Comparison of the effectiveness of various neural network models applied to wind turbine condition diagnosis (풍력터빈 상태진단에 적용된 다양한 신경망 모델의 유효성 비교)

  • Manh-Tuan Ngo;Changhyun Kim;Minh-Chau Dinh;Minwon Park
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.5
    • /
    • pp.77-87
    • /
    • 2023
  • Wind turbines playing a critical role in renewable energy generation, accurately assessing their operational status is crucial for maximizing energy production and minimizing downtime. This study conducts a comparative analysis of different neural network models for wind turbine condition diagnosis, evaluating their effectiveness using a dataset containing sensor measurements and historical turbine data. The study utilized supervisory control and data acquisition data, collected from 2 MW doubly-fed induction generator-based wind turbine system (Model HQ2000), for the analysis. Various neural network models such as artificial neural network, long short-term memory, and recurrent neural network were built, considering factors like activation function and hidden layers. Symmetric mean absolute percentage error were used to evaluate the performance of the models. Based on the evaluation, conclusions were drawn regarding the relative effectiveness of the neural network models for wind turbine condition diagnosis. The research results guide model selection for wind turbine condition diagnosis, contributing to improved reliability and efficiency through advanced neural network-based techniques and identifying future research directions for further advancements.

Prioritizing for Failure Modes of Dynamic Positioning System Using Fuzzy-FMEA (Fuzzy-FMEA를 이용한 동적위치제어 시스템의 고장유형 우선순위 도출)

  • Baek, Gyeongdong;Kim, Sungshin;Cheon, Seongpyo;Suh, Heungwon;Lee, Daehyung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.174-179
    • /
    • 2015
  • Failure Mode and Effects Analysis (FMEA) has been used by Dynamic Positioning (DP) system for risk and reliability analysis. However, there are limitations associated with its implementation in offshore project. 1) since the failure data measured from the SCADA system is missing or unreliable, assessments of Severity, Occurrence, Detection are based on expert's knowledge; 2) it is not easy for experts to precisely evaluate the three risk factors. The risk factors are often expressed in a linguistic way. 3) the relative importance among three risk factors are rarely even considered. To solve these problems and improve the effectiveness of the traditional FMEA, we suggest a Fuzzy-FMEA method for risk and failure mode analysis in Dynamic Positioning System of offshore. The information gathered from DP FMEA report and DP FMEA Proving Trials is expressed using fuzzy linguistic terms. The proposed method is applied to an offshore Dynamic Positioning system, and the results are compared with traditional FMEA.

Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps (소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.