• Title/Summary/Keyword: Supervisory control

Search Result 351, Processing Time 0.03 seconds

Deterministic rule-based control classification for HEV (하이브리드 차량의 SOC 유지전략 방법)

  • Byun, Sang-Min;Kim, Beom-Soo;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.357-360
    • /
    • 2008
  • There are many control strategies for HEV in today. Expanding motor-driving and operating at good-efficient point in engine is the key of the HEV control to increase fuel economy. There are two types of HEV supervisory control. One is rule-based control and the other is optimization control. MAX-SOC control, thermostat control, baseline status control and state-machine control are in deterministic RBC. It is simple, but powerful and easy to apply in real-time circumstance. In this study, we analysis these four control strategies in RBC (Rule-based control) and identify the each advantage and disadvantage.

  • PDF

A study on the error recovery method of the practical supervisory control using computer graphic simulation (컴퓨터 그래픽 시뮬레이션을 이용한 감시제어작업에서의 에러회복방법에 관한 연구)

  • ;長町三生;伊藤宏司
    • Journal of the Ergonomics Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.3-9
    • /
    • 1986
  • The present paper deals with obtaining the proper application criteria for the control mode, by using computer graphic simulation, in order to recover the error effectively occurring in the practical supervisory contol work of hyman-robot system. In these experiments the opteations by human and by control program are performed as control modes for recovering the error. And then we compare and analyze tow control modes taking task error and task time as performance measures and task difficulty as a variable factor. Consequently as the task difficulty increases, the task error in the operation by hyman tends to be less than in the operation by control program and the task time is superior in the operation by control program. Therefore, we suggest that two control modes should be used jointly for recovering the error and the operation by control program should be applied in major fraction of control and the operation by human in minor fraction of control.

  • PDF

A Study on Predictive Fuzzy Control Algorithm for Elevator Group Supervisory System (엘리버이터 군관리 시스템을 위한 예견퍼지 제어 알고리즘에 관한 연구)

  • Choi, Don;Park, Hee-Chul;Woo, Kang-Bang
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.627-637
    • /
    • 1994
  • In this study, a predictive fuzzy control algorithm to supervise the elevator system with plural cars is developed and its performance is evaluated. The proposed algorithm is based on fuzzy in-ference system to cope with multiple control objects and uncertainty of system state. The control objects are represented as linguistic predictive fuzzy rules and simplified reasoning method is utilized as a fuzzy inference method. Real-time simulation is performed with respect o all possible modes of control, and the resultant controls ard predicted. The predicted rusults are then utilized as the control in-puts of the fuzzy rules. The feasibility of the proposed control algorithm is evaluated by graphic simulator on computer. Finallu, the results of graphic simulation is compared with those of a conventional group control algorighm.

  • PDF

Optimal Control for Central Cooling Systems (중앙냉방시스템의 최적제어에 관한 연구)

  • 안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.354-362
    • /
    • 2000
  • Optimal supervisory control strategy for the set points of controlled variables in the central cooling system has been studied by computer simulation. A quadratic linear regression equation for predicting the total cooling system power in terms of the controlled and uncontrolled variables was developed using simulated data collected under different values of controlled and uncontrolled variables. The optimal set temperatures such as supply air temperature, chilled water temperature, and condenser water temperature, are determined such that energy consumption is minimized as uncontrolled variables, load, ambient wet bulb temperature, and sensible heat ratio, are changed. The chilled water loop pump and cooling tower fan speeds are controlled by the PID controller such that the supply air and condenser water set temperatures reach the set points designated by the optimal supervisory controller. The influences of the controlled variables on the total system and component power consumption was determined. It is possible to minimize total energy consumption by selecting the optimal set temperatures through the trade-off among the component powers. The total system power is minimized at lower supply, higher chilled water, and lower condenser water set temperature conditions.

  • PDF

Sensors Network and Security and Multimedia Enhancement

  • Woo, Seon-mi;Lee, Malrey
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.1
    • /
    • pp.64-68
    • /
    • 2016
  • These fields are integrated to visualize and finalize the proposed development, in simulation environment. SCADA (supervisory control and data acquisition) systems and distributed control systems (DCSs) are widely deployed in all over the world, which are designed to control the industrial infrastructures, in real ways. To supervise and control the various parts of designed systems; trends to require a deep knowledge to understand the overall functional needs of industries, which could be a big challenge. Industrial field devices (or network sensors) are usually distributed in many locations and are controlled from centralized site (or main control center); the communication provides various signs of security issues. To handle these issues, the research contribution will twofold: a method using cryptography is deployed in critical systems for security purposes and overall transmission is controlled from main controller site. At controller site, multimedia components are employed to control the overall transmission graphically, such as system communication, bytes flows, security embedded parameters and others, by the means of multimedia technology.

Robust control of PID control system using feedfoward supervisory controller (전향 관리제어기에 의한 PID제어 시스템의 강인제어)

  • Park, Min-Gyu;Kim, Young-Wook;Jeon, Jeong-Chay;Oh, Hun;Park, Wal-Seo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.887-889
    • /
    • 1999
  • Robust control is needed according to the highest precision of industrial automation. However, when a control system with PID controller has an effect of load disturbance, it is difficult to guarantee the robustness of control system, as a method solving this problem, in this paper. Feedfoward supervisory control method for PID control system is presented the effectiveness of the control scheme is verified by simulation results.

  • PDF

A study on the supervisory control of digital instrumentation and control system for power plant (발전소 제어용 디지탈 계장제어 시스템의 관리제어에 관한 연구)

  • 권만준;이재혁;김병국;변증남;배병환;박익수;허성광
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.204-208
    • /
    • 1990
  • The digital instrumentation and control system for the large scale system like the power plant must have the form of the heirachical structure. Because most large scale system have many control and process signals and it is distributed in the vade region, it is necessary to partition them into several subsystems. Therefore, the role of SCS(Supervisory Control System) having the functions of controlling and monitoring for the status of subsystems is very important. In this paper, new SCS for the effective control of the large scale system is proposed.

  • PDF

Supervisory Control of FMS's Using Colored Resource-Oriented Petri Net and Temporal Logic Frameworks (시간논리 구조와 Colored Resource-Oriented Petri Net을 이용한 FMS's의 감시제어)

  • Kim, Jung-Chul;Kim, Jin-Kwon;Hwang, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2045-2047
    • /
    • 2001
  • In this paper, we proposed the representation method of specification and the control rules fork FMS by TPL. To increase productivity and resource utilization, it is desirable to have more active jobs in the system, but the more active jobs there are, the more easily deadlock occur. Therefore, it is very important that the real-time deadlock control to disable deadlock. In this paper, we performed the system modeling by the CROPN(Colored Resource -Oriented Petri Net) and the necessary -sufficient condition check to disable deadlock. We proposed the supervisory control system that can be the real-time monitoring for deadlock free through a necessary-sufficient condition by CROPN modelling, and designed the logic controller of the extended process using TPL.

  • PDF

A Study on Computer Application Program to an Efficient Supervisory Control of the Power Distribution System (효율적인 배전관리를 위한 컴퓨터 응용 프로그램 연구)

  • Lee, B.C.;Seo, Y.R.;Lee, J.H.;Chung, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.96-98
    • /
    • 1993
  • In accordance with increase of electrical power demanded, more efficient supervisory control of distribution system is required. This study contains development of MMI(man-machine-interface) system with GUI(graphic-user-interface), for the automatic power distribution system. The main function of MMI system are to edit network of power distribution, to view network, to warnning a breakdown and to management of data base for network. The GUI function of MMI system enables more efficient management of power distribution system.

  • PDF

A Study on Manufacturing Process Control and Monitoring System for Heat-Shrink-Tube Cutting Machine (열 수축 튜브 자동 절단 장치를 위한 공정제어 및 감시 시스템에 관한 연구)

  • Kim, Hyoung-Seok;Lee, Byung-Ryong;Yun, Ho-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1140-1145
    • /
    • 2008
  • In conventional cutting system of Heat-Shrink-Tube, workers operate cutting system after considering about length and quantity of heat-shrink-tube. So, not only work time and production cost is increased but also material is wasted because the data that workers have to consider is so much. In this paper, an effective cutting system of heat-shrink-tube was developed to reduce production cost, work time and waste of material. The cutting system consists of a supervisory computer installed inside a control room, a on-site computer installed on the work area, and a PLC system. In the developed system, a supervisory computer send work order to the on-site computer using LAN and the on-site computer operates the cutting system of the heatshrink-tube after it makes an array production order. Also, the on-site computer reports information to the supervisory computer when an accident happened.