• Title/Summary/Keyword: Supervisory Control and Data Acquisition (SCADA)

Search Result 109, Processing Time 0.042 seconds

Application of Data Processing Technology on Large Clusters to Distribution Automation System (대용량 데이터 처리기술을 배전자동화 시스템에 적용)

  • Lee, Sung-Woo;Ha, Bok-Nam;Seo, In-Yong;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.245-251
    • /
    • 2011
  • Quantities of data in the DMS (Distribution management system) or SCADA (Supervisory control and data acquisition) system is enormously large as illustrated by the usage of term flooding of data. This enormous quantity of data is transmitted to the status data or event data of the on-site apparatus in real-time. In addition, if GIS (Geographic information system) and AMR (Automatic meter reading), etc are integrated, the quantity of data to be processed in real-time increases unimaginably. Increase in the quantity of data due to addition of system or increase in the on-site facilities cannot be handled through the currently used Single Thread format of data processing technology. However, if Multi Thread technology that utilizes LF-POOL (Leader Follower -POOL) is applied in processing large quantity of data, large quantity of data can be processed in short period of time and the load on the server can be minimized. In this Study, the actual materialization and functions of LF POOL technology are examined.

DLMS SCADA System based on TETRA (TETRA 기반 DLMS 원방감시 시스템)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. DLMS(Device Language Message Specification) is used in order to meter an electric measuring instrument value. In this paper, DLMS Server and Client simulator are used based on Window operating system. The multi-functional gateway, which transforms the communications based on RS-232C between DLMS Server Simulator and Client Simulator to the one based on TETRA PEI(Peripheral Equipment Interface), is developed such that DLMS SCADA(Supervisory Control And Data Acquisition) system is constructed based on TETRA.

  • PDF

Fuzzy Petri-net Approach to Fault Diagnosis in Power Systems Using the Time Sequence Information of Protection System

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1727-1731
    • /
    • 2003
  • In this paper we proposed backward fuzzy Petri-net to diagnoses faults in power systems by using the time sequence information of protection system. As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. The fuzzy Petri-net models of protection system are composed of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model, which makes use of the nature of fuzzy Petri-net, is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA (Supervisory Control and Data Acquisition)

  • PDF

A Study on Introducing Security Certification for Control Systems (제어시스템 보안인증 도입 방안 연구)

  • Choi, Hoyeol;Kim, Daeyeong;Shin, Hyungjune;Hahn, Changhee;Hur, Junbeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.3
    • /
    • pp.725-734
    • /
    • 2016
  • SCADA(Supervisory Control and Data Acquisition) system is widely used for remote monitoring and control throughout the domestic industry. Due to a recent breach of security on SCADA systems, such as Stuxnet, the need of correctly established secure certification of a control system is growing. Currently, EDSA-CRT (Embedded Device Security Assurance-Communication Robustness Test), which tests the ability to provide core services properly in a normal/abnormal network protocol, is only focused on the testing of IP-based protocols such as IP, ARP, TCP, etc. Thus, in this paper, we propose test requirements for DNP3 protocol based on EDSA-CRT. Our analysis show that the specific test cases provide plentiful evidences that DNP3 should follow based on its functional requirements. As a result, we propose 33 specific test case for DNP3 protocol.

Calculation of Network Analysis and Fault Decision using Equality Constraint Condition with MATLAB (등호제약조건을 이용한 계통 해석 및 고장판단 계산 구현)

  • Yang, Min-Uk;Kim, Kern-Joong;Hwang, In-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2101-2106
    • /
    • 2009
  • The power system state estimation and prediction are very important for operation. Because that accidents of the Power system are the cause that many devices and etc are damaged. Currently, almost every power systems have 2nd,3rd back-upsystem for prevention of accident. But prevention of accident by miss-operation, due to operator or miss data, has not acounter plan. Because, we need to estimate the power system for correcting miss data and preventing miss operation by operator. We suggest algorithm for integrity of power system network data.

Condition Assessment for Wind Turbines with Doubly Fed Induction Generators Based on SCADA Data

  • Sun, Peng;Li, Jian;Wang, Caisheng;Yan, Yonglong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.689-700
    • /
    • 2017
  • This paper presents an effective approach for wind turbine (WT) condition assessment based on the data collected from wind farm supervisory control and data acquisition (SCADA) system. Three types of assessment indices are determined based on the monitoring parameters obtained from the SCADA system. Neural Networks (NNs) are used to establish prediction models for the assessment indices that are dependent on environmental conditions such as ambient temperature and wind speed. An abnormal level index (ALI) is defined to quantify the abnormal level of the proposed indices. Prediction errors of the prediction models follow a normal distribution. Thus, the ALIs can be calculated based on the probability density function of normal distribution. For other assessment indices, the ALIs are calculated by the nonparametric estimation based cumulative probability density function. A Back-Propagation NN (BPNN) algorithm is used for the overall WT condition assessment. The inputs to the BPNN are the ALIs of the proposed indices. The network structure and the number of nodes in the hidden layer are carefully chosen when the BPNN model is being trained. The condition assessment method has been used for real 1.5 MW WTs with doubly fed induction generators. Results show that the proposed assessment method could effectively predict the change of operating conditions prior to fault occurrences and provide early alarming of the developing faults of WTs.

A Study on the Container for OPC-based OLE Controls (OPC 기반의 OLE 컨트롤들을 위한 컨테이너의 연구)

  • 박성규;심민석;유대승;김종환;이명재
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.736-738
    • /
    • 2004
  • 현재 수많은 OPC(OLE Process Control)관련 제품들이 나와 있다. 특히, 클라이언트 제품군 가운데 가장 많이 눈에 띄는 것은 OPC 서버와 통신하여 사용자에게 장비의 정보를 전달하거나 장비를 제어 할 수 있는 OLE(Object Linking and Embedding) 컨트롤(ActiveX 컨트롤)들이다. 하지만. 이러한 OLE 컨트롤을 시스템에 적용하기 위해서는 이를 지원하는 개발 언어와 컴파일러에 대한 프로그래밍적 지식이 필요하다. 이에 본 논문에서는 프로그래밍에 대한 전문적 지식이 없이도 HMI(Human Machine Interface) / SCADA(Supervisory Control and Data Acquisition)와 같은 시스템을 구축할 수 있도록 OLE 컨트롤 컨테이너를 제공함으로써 사용자가 쉽게 디자인할 수 있는 방법을 제시한다. 본 논문에서 제안하고자 하는 OLE 컨트롤 컨테이너는 OLE/COM 기술을 기반으로 하는 OLE 컨트롤을 지원하고 웹으로의 빠른 확장을 위해 설계되었다.

  • PDF

Information and Communication Technologies for Smart Water Grid Applications

  • Ballhysa, Nobel;Choi, Gyewoon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.218-226
    • /
    • 2019
  • The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.

A Study on Fault Diagnosis of Power System Using Fuzzy Petri Nets (퍼지 페트리네트를 이용한 전력계통 고장진단에 관한 연구)

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.122-124
    • /
    • 2000
  • As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. Therefore this paper proposes a method of the modeling of protection systems and fault diagnosis in power systems using Fuzzy Petri Nets (FPN). The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method can cover online processing of real-time data from SCADA (Supervisory Control and Data Acquisition).

  • PDF

A Framework on secure remote control in plant system (안전한 공장 원격제어 시스템 프레임 워크)

  • Lee, Jaemin;Mun, Jiman;Jung, Souhwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.989-992
    • /
    • 2012
  • 본 논문에서는 안전한 공장 원격제어를 위한 시스템 프레임 워크를 제안한다. 공장기계와 IT의 융합으로 기술 발전함에 따라 공장 제어 시스템을 공장내부에서는 무선 제어시스템, 공장 외부에서는 원격 시스템의 필요성이 대두되어 많은 연구들이 진행되고 있다. 기존의 공장 자동화 시스템 SCADA(Supervisory Control And Data Acquisition)는 생산 공정 및 플랜트의 상태를 감시하고 제어하기 위한 목적으로 개발되었지만 원격제어 관련 내용이 부족하다. 공장 내부 보안을 위한 표준으로 ISA99 Security Standards에서도 통합 공정 제어 Zone & Conduits 방식 제시 공장의 각 영역을 Zone으로 나누고 허가된 사용자만 Conduit를 통해 다른 Zone의 노드와 통신을 하는 방식을 제안하였다. 하지만, 전체적인 프레임워크는 정의를 하고 있으나 외부 원격 제어 내용 부족하다. 따라서 본 논문에서는 스마트폰을 활용한 공장 외부에서의 안전한 원격 제어를 제공하는 통합관제시스템 프레임워크 구조를 제시하여 향후 관련 기술에 대한 기준점을 제시한다.