• Title/Summary/Keyword: Superior line

Search Result 531, Processing Time 0.027 seconds

Physiological Evaluation of Transgenic Rice Developed for Drought Tolerance

  • Ghimiren Sita Ram;Park Sang-Kyu;Kang Dong-Jin;Lee In-Jung;Shin Dong-Hyun;Kim Sung-Uk;Kim Kil-Ung
    • Journal of Plant Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.133-137
    • /
    • 2006
  • Evaluation of physiological performance of trehalose-producing transgenic rice line was conducted to investigate drought tolerance at early growth stage. Under artificially induced drought condition of 8% polyethylene glycol 6000, this transgenic rice line had leaf photosynthetic rate of 11.08 uml CO$_2$ $m^{-2}s^{-1}$, leaf transpiration rate of 8.38 mmol $H_2O$ $m^{-2}s^{-1}$ and leaf water potential of -1.12 MPa after 96 hours of treatment. Nakdongbyeo, the parent of this tyansgenic rice line, had photosynthetic rate of 15.42 $\mu$mol CO$_2$ $m^{-2}s^{-1}$, leaf transpiration rate of 8,04 mmol $H_2O$ $m^{-2}s^{-1}$ and leaf water potential of -0.88 MPa. The other variety used in this experiment for comparison, IR 72, showed higher values than both tyansgenic rice line and variety Nakdonbyeo on all three parameters; leaf photosynthetic rate of 20.61 $\mu$mol CO$_2$ $m^{-2}s^{-1}$, leaf transpiration rate of 12.88 mmol $H_2O$ $m^{-2}s^{-1}$, and leaf water potential of -0.82 MPa. So this transgenic rice line did not show superior performance in leaf transpiration rate, leaf photosynthetic rate and leaf water potential compared to variety Nakdongbyeo. This result along with visual observation on leaf rolling and drying during the experimental period indicated poor physiological performance of this transgenic rice line. Further studies on metabolic status of stress-induced trehalose, along with study on physiological response of this transgenic rice line during drought stress would shed more light on overall physiological performance of this transgenic rice line.

Evaluation of Propolis Productivity among Honey Bee Lines to Select Superior Lines (프로폴리스 생산성 우수 꿀벌 계통 선발을 위한 꿀벌 계통별 프로폴리스 생산성 평가)

  • Oh, Hyun-Rim;Kim, Hye-Kyung;Lee, Myeong-Lyeol;Lee, Man-young;Kim, Dong Won;Woo, Soon-Ok;Kang, Ah Rang;Choi, Yong-Soo
    • Journal of Apiculture
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Honey bees use propolis to defend against invaders and pathogens. Propolis, a resinous mixture, has been widely used for its antibacterial, antifungal and anti-inflammatory properties. This research was carried out to evaluate the propolis productivity in Apis mellifera lines to select superior honeybee lines. For the study, which were collected from three regions in Korea were evaluated for the productivity of propolis. The results showed that, the average propolis per colony was highest in the line P2 (10.1 g/hive), which was inbed line derived from isolated region, compared to other lines. We also measured brood development one the basis of population size of eggs, brood, and adult bees to further probe for relation between population size and propolis yield, in that larger population generally have more foragers. Also, adult population expended more greatly in the line P2 compared to that in the control.

Safely Evaluation on Common Grounding System for Electric Railway (전기철도의 공용접지 시스템에 대한 안정성 평가에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.298-306
    • /
    • 2002
  • We performed an safety evaluation on constructing of a common grounding system for electrical railway in view of its efficacy and technical fit. In order to compare the conventional grounding method, which has been individually conducted, with the common grounding with all ground wires connected in common to the counterpoise buried below the surface of the earth in parallel with rail, we set up scenarios with several cases of fault and load conditions in Chungbuk railway sections with the common grounding system. Based on models for railway conductors including the grounded system, line Parameters of railway power system are computed. The circuit model for power system with up and down lines, auto-transformers and railway substations is used to compute impedances of counterpoise and substation ground net. For each scenario with faults and operation conditions of railway, the induced potentials on signal and communication lines are also computed. It is shown that the common grounding for Chungbuk railway is superior experimentally to the conventional method in three respects: (1) the lower rail potentials during operation of railway in line, (2) the lower rail potentials for short-circuit faults between catenary and rail, and (3) the lower stress voltages on signal and communication lines for short-circuit or ground faults. The analysis results confirm that the grounding system for electric railway is required to be built by the common grounding and be evaluated on its safety in design.

The Application of the Lee's Menu Engineering Method for Italian Pizzas (Lee's 메뉴엔지니어링 분석법(LME)의 적용 - 이탈리아 피자류를 중심으로 -)

  • Lee, Sung-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.33 no.1
    • /
    • pp.111-115
    • /
    • 2020
  • The purpose of this study is an application of Lee's Menu Engineering (LME) method for menu analysis on the eight kinds of pizza selected from 17 kinds of pizza served by an Italian restaurant near by the Keimyung College University campus. The eliminated nine items were in the third quadrant or below the trend line. The LME method is more efficient than generally used methods such as the Miller, Kasavana & Smith, Uman, Pavesic and Merricks & Jones method. The LME method comprises reference lines and four quadrants created by x, y axes and its average values. The x and y axes comprise the sales ratio (MM%, percentage of the Menu Mix) and the weighted contribution margin (WCM%, percentage of the Weighted Contribution Margin) respectively. The obtained results are such that total sales increased by 1.59% from 58,747,200 won to 59,684,000 won, despite the decrease in sales volume. Total contribution margin also increased from 35,248,320 won to 35,810,400 won. The trend line also shows from y=0.9147x (R2=0.703) to y=0.9944x (R2=0.9893). These results indicate that the LME method is superior in practical applications.

On the TFT-LCD Cell Defect Inspection Algorithm using Morphology (모폴로지(Morphology)를 이용한 TFT-LCD 셀 검사 알고리즘 연구)

  • Kim, Yong-Kwan;Yu, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • In this paper, we develope and implement a TFT-LCD cell defects detection algorithm using morphology. To detect the bright line or dark line defects and the bright pixel or dark pixel defects of the TFT-LCD cells, we determine the shape of the morphology operators considering the shape characteristics of the TFT-LCD sub pixels. Using dilation, erosion, and the subtraction operators, we extract gray level defects information. Then, we apply the optimal threshold method which shows the best results in terms of several criteria. Finally, we determine the defects using labelling method. From various experiments using TFT-LCD panels, the proposed algorithm shows superior results.

Reliability Assessment of Forest Fire on EHV Polymer Insulator Strings (송전용 폴리머애자의 산불 영향 신뢰성 평가)

  • Min, Byeong-Wook;Shin, Tai-Woo;Choi, In-Hyuk;Choi, Han-Yeol;Park, Jae-Ung;Yu, Kun-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.436-437
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea but polymer insulators which are superior in that they are light weight, explosion proof, impact proof, economical with construction characteristics, have been in use for the 154kV transmission line since 1999 following a worldwide trend towards the reduced weight, simplification and compact usage of new material insulators. However there have been approximately 500 cases of forest fires in Korea, so the transmission lines that for the most part pass through mountainous areas have been highly effected and the highly polymerized compound polymer insulator has raised concern about reliability in cases of exposure to forest fires. Therefore for the reliability assessment of the effect of forest fires on polymer insulators, mechanical and electrical characteristics are analyzed by an artificial flare test device and transmission facility surrounding conditions along with forest fire characteristics are surveyed. In addition to this, actual 90kV energized transmission line was tested with an artificial forest fire and the expanded usage of polymer insulators is presented through the analysis of mechanical and electrical characteristics and physical properties, and a study on the influence of forest fires on polymer insulators.

  • PDF

A Verification Method for Handwritten text in Off-line Environment Using Dynamic Programming (동적 프로그래밍을 이용한 오프라인 환경의 문서에 대한 필적 분석 방법)

  • Kim, Se-Hoon;Kim, Gye-Young;Choi, Hyung-Il
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.12
    • /
    • pp.1009-1015
    • /
    • 2009
  • Handwriting verification is a technique of distinguishing the same person's handwriting specimen from imitations with any two or more texts using one's handwriting individuality. This paper suggests an effective verification method for the handwritten signature or text on the off-line environment using pattern recognition technology. The core processes of the method which has been researched in this paper are extraction of letter area, extraction of features employing structural characteristics of handwritten text, feature analysis employing DTW(Dynamic Time Warping) algorithm and PCA(Principal Component Analysis). The experimental results show a superior performance of the suggested method.

A Study on Measurement Techniques of EM Wave Absorbing Ability of a RAM for RF Stealth (RF 스텔스용 RAM의 전파흡수능 측정기법에 관한 연구)

  • Choi, Chang-Mook;Lim, Bong-Taeck;Ko, Kwang-Soob
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1331-1337
    • /
    • 2010
  • In this paper, measurement techniques of absorbing ability for a RAM were studied for RCS Reduction needed for materializing ADD's RF stealth. As for the measurement techniques of absorbing ability, the theories of the free space method, similar to real radar system, and transmission line method, suitable for lab scale, were established. And we made real RAM samples, measured absorbing ability according to each, and compared the results. After comparison, electromagnetic(EM) wave absorbing ability was measured to be somewhat superior in free space method and overall uniform pattern was observed. Therefore, by applying measurement techniques by stage and by frequency we could develop RAM in a more efficient way.

Experimental study on simplified steel reinforced concrete beam-column joints in construction technology

  • Teraoka, Masaru;Morita, Koji;Sasaki, Satoshi;Katsura, Daisuke
    • Steel and Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.295-312
    • /
    • 2001
  • The purpose of this paper is to propose a new type of steel reinforced concrete (SRC) beam-column joints and to examine the structural performance of the proposed joints, which simplify the construction procedure of steel fabrication, welding works, concrete casting and joint strengthening. In the proposed beam-column joints, the steel element of columns forms continuously built-in crossing of H-sections (${\Box}$), with adjacent flanges of column being connected by horizontal stiffeners in a joint at the level of the beam flanges. In addition, simplified lateral reinforcement (${\Box}$) is adopted in a joint to confine the longitudinal reinforcing bars in columns. Experimental and analytical studies have been carried out to estimate the structural performance of the proposed joints. Twelve cruciform specimens and seven SRC beam-column subassemblage specimens were prepared and tested. The following can be concluded from this study: (1) SRC subassemblages with the proposed beam-column joints show adequate seismic performances which are superior to the demand of the current code; (2) The yield and ultimate strength capacities of the beam-to-column connections can be estimated by analysis based on the yield line theory; (3) The skeleton curves and the ultimate shear capacities of the beam-column joint panel are predicted with a fair degree of accuracy by considering a simple stress transfer mechanism.

Effective technique to analyze transmission line conductors under high intensity winds

  • Aboshosha, Haitham;El Damatty, Ashraf
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.235-252
    • /
    • 2014
  • An effective numerical technique to calculate the reactions of a multi-spanned transmission line conductor system, under arbitrary loads varying along the spans, is developed. Such variable loads are generated by High Intensity Wind (HIW) events in the form of tornadoes and downburst. First, a semi-closed form solution is derived to obtain the displacements and the reactions at the ends of each conductor span. The solution accounts for the nonlinearity of the system and the flexibility of the insulators. Second, a numerical scheme to solve the derived closed-form solution is proposed. Two conductor systems are analyzed under loads resulting from HIW events for validation of the proposed technique. Non-linear Finite Element Analyses (FEA) are also conducted for the same two systems. The responses resulting from the technique are shown to be in a very good agreement with those resulting from the FEA, which confirms the technique accuracy. Meanwhile, the semi-closed form technique shows superior efficiency in terms of the required computational time. The saving in computational time has a great advantage in predicting the response of the conductors under HIW events, since this requires a large number of analyses to cover different potential locations and sizes of those localized events.