• 제목/요약/키워드: Superheat control

검색결과 63건 처리시간 0.032초

멀티형 히트펌프 전자팽창밸브의 디더 신호를 적용한 과열도 제어 (EEV Superheat Control of a Multi-type Heat Pump by Using Dither Signal)

  • 한도영;표수환
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electronic expansion valve (EEV) may be used to control the refrigerant flow rate for the multi-type heat pump. Stepping motor driven EEV may precisely control the refrigerant flow rate to meet each internal load requirement. To control the EEV, PI algorithm may be used. But the hysteresis of EEV deteriorates the performance of superheat control. To reduce the performance degradation, the PI algorithm along with the dither signal may be used. The dither signal, with about 10 times higher frequency than the system crossover frequency and about 10 times larger magnitude than the deadband of hysteresis, was selected for the superheat control of EEV. Experimental results showed the improvement of EEV control by adding the dither signal to the PI algorithm.

가변속 열펌프의 과열도 제어특성에 관한 실험적 연구 (Experimental Study on Superheat Control of a Variable Speed Heat Pump)

  • 최종민;김용찬;하진호
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.233-241
    • /
    • 2001
  • In the present study, various experiments were performed to investigate the capacity modulation and transient response control using a variable speed compressor and electronic expansion valve(EEV). Based on the experimental results, the operation control algorithm and real time digital control system were constructed to adjust the superheat at the inlet of the compressor. Superheat control was fulfilled using both the PI feedback controller and PI controller combined with a feedforward concept. As a result, the tracking performance of the latter was better than that of former.

  • PDF

냉동사이클의 최적 제어를 위한 증발기 동특성 해석 (Dynamic Analysis of Evaporator for Optimum Control in Refrigeration System)

  • 정석권;;최광환;윤정인;김은필
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.82-88
    • /
    • 2005
  • This paper presents numerical study on dynamic characteristics of evaporator to control evaporator superheat and compressor capacity with optimum condition in refrigeration system. It is very important to reduce energy consumption and to keep room temperature within a very restricted range with minimum oscillation in some special applications of the refrigeration system. Heat exchange is mainly happened in the evaporator. So, making mathematical model of evaporator and analyzing evaporator characteristics are necessary in order to control the superheat and the capacity of the system. A mathematical model based on the one dimensional partial differential equations representing mass and energy conservation and a tube-wall energy is described. A set of ordinary differential equation is formulated by integrating separately over the two regions(two-phase and vapor) generally presented in a heat exchanger.

  • PDF

High Efficient Control Design for Refrigeration System of a Ship

  • Hua, Li
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.241-244
    • /
    • 2006
  • In this paper, we suggest the high efficient control method based on general PI control law to control the refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering at first. Next, we design PI controller to control capacity and superheat independently. Finally the control performance was investigated through some experiments. The experiments results show that the PI control design can obtain good control performance deal with the varied control reference and thermal load.

  • PDF

전자팽창밸브 제어성능 모사용 증발기 동특성 모델링 (A Dynamic Simulation Model of Electronic-Expansion-Valve-Controlled Evaporators)

  • 신영기;조수;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.183-190
    • /
    • 2007
  • Controlling superheat of indoor units associated with a multi-type heat pump is one of difficult tasks to be addressed. This study suggests a dynamic model of an evaporator based on heat and mass balance. Thermodynamic properties are calculated by a commercial software, Refprop. The model is programmed in MFC Visual C++ for controller interface in real-time mode. The simulation results shows that PI control works for a narrow range of superheat. Beyond the range, the temperature behavior of the refrigerant is quite nonlinear mainly due to phase change. Thus, it is concluded that PI control of superheat has to be supplemented by nonlinear control ideas to avoid saturation and excessive superheat.

공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성 (Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems)

  • 김재돌;장재은;윤정인
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

과열도 변화에 의한 $NH_3$ 냉동장치의 성능특성 연구 (The Study on Performance Characteristics due to the Superheat Temperature of $NH_3$ Refrigeration System)

  • 전상신;권일욱;하옥남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1334-1339
    • /
    • 2004
  • Nowadays CFCs and HCFCs refrigerants are restricted because it cause depletion of ozone layer. Accordingly, this experiment apply the $NH_3$ gas and not CFCs and HCFCs for refrigerant to study the performance characteristic from the superheat control and improve the energy efficiency from the high performance. The condensing pressure of refrigeration system is increased from 14.5bar to 16bar by 0.5bar and superheat temperature is increased from $0^{\circ}C$ to $10^{\circ}C$ by $1^{\circ}C$ at each condensing pressure. As the result of experiment, when the superheat temperature is $1^{\circ}C$ at each condensing pressure, the refrigeration system has the high performance.

  • PDF

멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어 (Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF

PI Control with the Smith Predictive Controller for a Variable Speed Refrigeration System

  • Hua, Li;Choi, Jeong-Pil;Jeong, Seok-Kwon;Yang, Joo-Ho;Kim, Dong-Gyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.129-136
    • /
    • 2007
  • In this paper, we suggest PI control with the Smith predictive controller to improve transient response of a variable speed refrigeration system (VSRS). As the refrigeration system has long dead time inherently, it is difficult to get fast responses of super-heat and reference temperature. We incorporated the Smith predictive controller into PI to compensate the effect of the long dead time of the system. At first, we introduced the decoupling model of the system to control capacity and superheat simultaneously and independently. Next, we designed the predictive controller of the superheat based on PI control law. Finally, the control performance by the proposed method was investigated through some numerical simulations and experiments. The results of the simulations and experiments showed that the proposed PI control with the predictive controller could obtain acceptable transient behaviour for the system.

Design of digital nuclear power small reactor once-through steam generator control system

  • Qian, Hong;Zou, Mingyao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2435-2443
    • /
    • 2022
  • The once-through steam generator used in the small modular reactor needs to consider the stability of the outlet steam pressure and steam superheat of the secondary circuit to achieve better operating efficiency. For this reason, this paper designs a controllable operation scheme for the steam pressure and superheat of the small reactor once-through steam generator. On this basis, designs a variable universe fuzzy controller, first, design the fuzzy control rules to make the controller adjust the PI controller parameters according to the change of the error; secondly, use the domain adjustment factor to further subdivide the input and output domain of the fuzzy controller according to the change of the error, to improve the system control performance. The simulation results show that the operation scheme proposed in this paper have better system performance than the original scheme of the small reactor system, and controller proposed in this paper have better control performance than traditional PI controller and fuzzy PI controller, what's more, the designed control system also showed better anti-disturbance performance in lifting experiment between 100% and 80% working conditions. Finally, the experimental platform formed by connecting the digital small reactor with Matlab/Simulink through OPC(OLE for Process Control) communication technology also verified the feasibility of the proposed scheme.