• Title/Summary/Keyword: Superconducting Quantum Interference Device

Search Result 88, Processing Time 0.03 seconds

Construction and Operation of a 40-channel SQUID System for Neuromagnetic Measurements (40-채널 SQUID 시스템의 제작 및 뇌자도 측정)

  • Lee, Yong-Ho;Kim, Jin-Mok;Kwon, Hyuk-Chan;Lee, Sang-Kil;Lim, Cheong-Moo;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.27-32
    • /
    • 1999
  • We developed a 40-channel superconducting quantum interference device (SQUID) system for neuromagnetic measurements. The main features of the system are use of double relaxation oscillation SQUID (DROS), and planar gradiometer for measuring tangential field components. The DROSS with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature electronics and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. The average noise of the 40 channels is around 1.2 fT/cm/${\sqrt{Hz}}$ at 100 Hz, corresponding to the field noise of 5 fT/${\sqrt{Hz}}$ at 100 Hz, operated inside a magnetically shielded room. The 40-Channel system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

The Bonding Nature and Low-Dimensional Magnetic Properties of Layered Mixed Cu(II)-Ni(II) Hydroxy Double Salts

  • Park, Seong-Hun;Huh, Young-Duk
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.768-772
    • /
    • 2013
  • Layered mixed metal hydroxy double salts (HDS) with the formulas $(Cu_{0.75}Ni_{0.25})_2(OH)_3NO_3$ ((Cu, Ni)-HDS) and $Cu_2(OH)_3NO_3$ ((Cu, Cu)-HDS) were prepared via slow hydrolysis reactions of CuO with $Ni(NO_3)_2$ and $Cu(NO_3)_2$, respectively. The crystal structures, morphologies, bonding natures, and magnetic properties of (Cu, Ni)-HDS and (Cu, Cu)-HDS were characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transformation infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), and a superconducting quantum interference device (SQUID). Even though (Cu, Ni)-HDS has a similar layered structure to that of (Cu, Cu)-HDS, the bonding nature of (Cu, Ni)-HDS is slightly different from that of (Cu, Cu)-HDS. Therefore, the magnetic properties of (Cu, Ni)-HDS are significantly different from those of (Cu, Cu)-HDS. The origin of the abnormal magnetic properties of (Cu, Ni)-HDS can be explained in terms of the bonding natures of the interlayer and intralayer structures.

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Development of magnetocardiograph system using YBCO SQUID magnetometers (YBCO SQUID 자력계를 이용한 자기심장검사장치 개발)

  • Kim, I.S.;Oh, S.H.;Lim, H.K.;Lee, Y.H.;Lee, S.G.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF

Stress Effects CoCr2O4 Film on MgO and MgAl2O4 Grown by RF-Sputter Process

  • Ko, Hoon;Choi, Kang-Ryong;Park, Seung-Iel;Shim, In-Bo;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.163-166
    • /
    • 2008
  • Multiferroic $CoCr_2O_4$ film was deposited on MgO and $MgAl_2O_4$ substrates by the rf-sputtering process. The films were prepared at an RF-magnetron sputtering power of 50 W and a pressure of 10 mtorr (20 sccm in Ar), and at substrate temperatures of $550^{\circ}C$. The crystal structure was determined to be a spinel (Fd-3m) structure by means of X-ray diffraction (XRD) with Cu $K{\yen}{\acute{a}}$ radiation. The thickness and morphology of the films were measured by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The magnetic properties were measured using a Superconducting Quantum Interference Device (SQIUD) magnetometer. While the ferrimagnetic transitions were observed at about 93 K, which was determined as the Neel temperature, the magnetic properties all show different behaviors. The differences between the magnetic properties can be explained by the stress effects between $CoCr_2O_4$ and the substrates of MgO and $MgAl_2O_4$.

Planar Hall Effect of GaMnAs Grown via low Temperature Molecular Beam Epitaxy (저온 분자선에피탁시 방법으로 성장시킨 GaMnAs의 planar Hall 효과)

  • Kim, Gyeong-Hyeon;Park, Jong-Hun;Kim, Byeong-Du;Kim, Do-Jin;Kim, Hyo-Jin;Im, Yeong-Eon;Kim, Chang-Su
    • Korean Journal of Materials Research
    • /
    • v.12 no.3
    • /
    • pp.195-199
    • /
    • 2002
  • Planar Hall effect of ferromagnetic GaMnAs thin films was investigated for the first time. The films were grown in an optimized growth condition via molecular beam epitaxy at low temperatures. For the optimization of the growth conditions, we used reflection high-energy electron diffraction, electrical conductivity, double crystal x-ray diffraction, and superconducting quantum interference device measurements techniques. We observed that the difference between the longitudinal resistance and the transverse resistance matches the planar Hall resistance. The ratio of the planar Hall resistance at saturation magnetic field to that at zero reached above 500%.

Synthesis of Composite Particles with Fe3O4 core and Ag Shell for the Development of Fingerprints

  • Zhang, Ling-Yan;Chu, Ting
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.1457-1461
    • /
    • 2013
  • The $Fe_3O_4$-core and Ag-shell ($Fe_3O_4@Ag$ nanoeggs) were prepared through the encapsulation of 3-aminopropyltriethoxysilane-coated magnetite nanoparticle in nano-Ag shell by a simple chemically controlled procedure. The $Fe_3O_4@Ag$ nanoeggs were characterized by scanning electron microscopy, transmission electron microscopy, UV-vis spectrum and superconducting quantum interference device magnetometer, respectively. A detailed analysis is provided of how the hydrolysis and condensation of 3-aminopropyltriethoxysilane and the pH value are vital in fabricating the $Fe_3O_4@Ag$ nanoeggs. The prepared $Fe_3O_4@Ag$ nanoeggs possessed uniform size, improved monodispersity, stability against aggregation and high magnetization, which were utilized for the detection of latent fingerprints deposited onto different surfaces. The experimental results showed that the latent fingerprints developed with the $Fe_3O_4@Ag$ nanoeggs powders exhibited excellent ridge details with minimal background staining.

FABRICATION OF HIGH QUALITY YBa$_2$Cu$_3$O$_{y}$ THIN FILMS USING PULSED LASER DEPOSITION

  • Lee, Eun-Hong;Park, Sang-Jin;Song, I-Hun;Song, In-Sang;Gohng, Jun-Ho;Sok, Jung-Hyun;Lee, Jo-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.437-442
    • /
    • 1996
  • High quality $YBa_2Cu_3O_y$(YBCO) thin films for directly coupled dc superconducting quantum interference device (SQUID) were fabricated by pulsed laser deposition. Several critical parameters have been optimized through systematic studies. Thus, the films showing the $T_c$ of above 91K and $J_c$ of above$2\times10^6A/cm^2$ at 77K were routinely obtained. Extensive AFM and X-ray diffraction studies have been conducted for morphological and structural analyses. The directly coupled DC-SQUIDs were fabricated from the YBCO thin films deposited on $SrTiO_3$ bicrystals under the optimized conditions. The measurement on $2I_c$ and swing voltage give 200$\mu$A and 17$\mu$V at 77K, respectively.

  • PDF

A Study on MCG Imaging (MCG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

Shape anisotropy and magnetic properties of Co/Ni anti-dot arrays

  • Deshpande, N.G.;Seo, M.S.;Kim, J.M.;Lee, S.J.;Lee, Y.P.;Rhee, J.Y.;Kim, K.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.444-444
    • /
    • 2011
  • Recently, patterned magnetic films and elements attract a wide interest due to their technological potentials in ultrahigh-density magnetic recording and spintronic devices. Among those patterned magnetic structures, magnetic anti-dot patterning induces a strong shape anisotropy in the film, which can control the magnetic properties such as coercivity, permeability, magnetization reversal process, and magneto-resistance. While majority of the previous works have been concentrated on anti-dot arrays with a single magnetic layer, there has been little work on multilayered anti-dot arrays. In this work, we report on study of the magnetic properties of bilayered anti-dot system consisting of upper perforated Co layer of 40 nm and lower continuous Ni layer of 5 nm thick, fabricated by photolithography and wet-etching processes. The magnetic hysteresis (M-H) loops were measured with a superconducting-quantum-interference-device (SQUID) magnetometer (Quantum Design: MPMS). For comparison, investigations on continuous Co thin film and single-layer Co anti-dot arrays were also performed. The magnetic-domain configuration has been measured by using a magnetic force microscope (PSIA: XE-100) equipped with magnetic tips (Nanosensors). An external electromagnet was employed while obtaining the MFM images. The MFM images revealed well-defined periodic domain networks which arise owing to the anisotropies such as magnetic uniaxial anisotropy, configurational anisotropy, etc. The inclusion of holes in a uniform magnetic film and the insertion of a uniform thin Ni layer, drastically affected the coercivity as compared with single Co anti-dot array, without severely affecting the saturation magnetization ($M_s$). The observed changes in the magnetic properties are closely related to the patterning that hinders the domain-wall motion as well as to the magneto-anisotropic bilayer structure.

  • PDF