• Title/Summary/Keyword: Superconducting Element

Search Result 272, Processing Time 0.028 seconds

Operation characteristics of a fault current limiter by high speed interrupter and a superconducting element

  • Im, I.G.;Jung, I.S.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.3
    • /
    • pp.10-14
    • /
    • 2014
  • Due to continuous increase of electric power consumption, couple of resolutions for improving accuracy in power system like line separation are being studied. The increase of the power demand can cause problems such as supply difficulties of the electricity and broadband outages, failure, etc. When a fault occurs in the power system, a fault current also increases. Fault current creates problems like reduction of lifespan and failure on the power system. In order to resolve these problems, the reduction of initial fault current using the characteristics of superconducting element was applied to fault current limiter. We applied the system to high speed fault current limiter. We found that the superconducting element effectively reduced initial fault current and the fault current was limited by changing operation of high speed interrupter.

Improvement of Quench Properties of a Flux-Lock Type Superconducting Fault Current Limiter by the Connection Method of YBCO Elements (YBCO소자의 연결방법에 의한 자속구속형 초전도 한류기의 퀜치특성의 향상)

  • Chung, Soo-Bok;Park, Hyoung-Min;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.323-327
    • /
    • 2008
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the methods of the serial and parallel connections between the superconducting elements. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series and parallel. In this paper, the analyses of voltage, current, and resistance of the superconducting elements connected in serial and parallel were performed to increase the power capacity of the flux-lock type SFCL. A part of the superconducting elements was not quenched in $2{\times}2$ serial connection between the elements and then the power burden of the quenched elements was increased. However the elements with $2{\times}2$ parallel connection was all quenched. This means that the power burden of each superconducting element can be reduced under the same conditions. We found that $2{\times}2$ parallel connection was more profitable for the current limiting effects and the increase of the power capacity.

Current Limiting Characteristics of a Flux-lock type SFCL with Secondary Windings Connected to the Superconducting elements in parallel (초전도 소자 병렬 연결에 따른 자속구속형 한류기의 전류제한 특성)

  • Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Jung, Soo-Bok;Lim, Sung-Hun;Choi, Myong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.229-230
    • /
    • 2007
  • We investigated the quench characteristics of a superconducting element, two superconducting elements in order to increase the current capacity of flux lock type SFCL. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series. The applied voltage at that time was 160 ${\sqrt{3}}$. We found that the parallel connection between the superconducting elements increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

Properties of a Hybrid Type Superconducting Fault Current Limiter using YBa2Cu3O7 Films (YBa2Cu3O7 박막을 이용한 하이브리드형 초전도 사고전류제한기의 특성)

  • Choi, Hyo-Sang;Cho, Yong-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.391-397
    • /
    • 2006
  • We present investigations of a hybrid type superconducting fault current limiter (SFCL), which consists of transformers and resistive superconducting elements. The secondary windings of the transformer were separated into several electrically isolated circuits and linked inductively with each other by mutual flux, each of which has a superconducting current limiting element of $YBa_2Cu_3O_7$ (YBCO) stripes as a current limiting element. Simple connection in series of the SFCL elements tends to produce ill-timed quenching because of power dissipation unbalance between SFCL elements. Both electrical isolation and mutual flux linkage of the elements provides a solution to power dissipation unbalance, inducing simultaneous quench and current redistribution of the YBCO films. This design enables to increase the voltage rating of SFCL with given YBCO stripes.

Influence of a Neutral Line on the Quench Behaviors of a Transformer Type SFCL (변압기형 초전도 한류기의 퀜치특성에 대한 중성선의 영향)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Koo, Kyung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2212-2213
    • /
    • 2008
  • In this paper, we studied the method for simultaneous quenching of a transformer type superconducting fault current limiter (SFCL) with two superconducting elements connected in series. Only an element between two elements of the transformer type SFCL was quenched like the case of the resistive type SFCL. By this quenching characteristics, the power burden of the superconducting element was increased. In order to solve this problem, we connected the neutral line between two superconducting elements and the center of secondary coils. The two elements were all quenched in the transformer type SFCL with a neutral line. As a result, the power burden of superconducting elements was decreased, so it was efficient for the increase of power capacity of the transformer type SFCL.

  • PDF

Design Optimization of Superconducting Magnet for Maximum Energy Storage (초전도 전자석의 저장에너지 최대화를 위한 최적설계)

  • Kim, Chang-Wook;Lee, Hyang-Beom;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.253-255
    • /
    • 1999
  • In this paper, a shape optimization algorithm of superconducting magnet using finite element method is presented. Since the superconductor loses its superconductivity over the critical magnetic field and critical current density, this material property should be taken into account in the design process. Trial and error approach of repeating the change of the design variables costs much time and it sometimes does not guarantee an optimal design. This paper presents a systematic and efficient design algorithm for the superconducting magnet. We employ the sensitivity analysis based on finite element formulation. As for optimization algorithm, the inequality constraint for the superconducting state is removed by modifying the objective function and the nonlinear equality constraint of constant volume is satisfied by the gradient projection method. This design algorithm is applied to an optimal design problem of a solenoid air-cored superconducting magnet that has a design objective of the maximum energy storage.

  • PDF

Operational Characteristics of SFCL using Magnetic Coupling of Coils (코일의 자기결합을 이용한 초전도 사고전류제한기의 동작특성)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.68-70
    • /
    • 2007
  • The operational characteristics of superconducting fault current limiter (SFCL) using magnetic coupling of coils were investigated. This SFCL consists of a high-Tc superconducting (HTSC) element and two coils with series or parallel connection on the same iron. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the resistance of HTSC element comprising this SFCL increased more than that of HTSC element's independent operation.

  • PDF

Voltage-Current Characteristics According to Fault Period of Flux-Lock SFCL with subtractive polarity winding (감극결선용 자속구속형 전류제한기의 사고주기별 전압전류 특성)

  • Han, Tae-Hee;Hwang, Jong-Sun;Cho, Yong-Sun;Park, Hyoung-Min;Nam, Guong-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Lim, Sung-Hun;Chung, Dong-Chul;Choi, Myoung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.101-102
    • /
    • 2006
  • We investigated the characteristics of flux-lock type superconducting fault current limiter (SFCL) by the fault cycles. Since the recovery characteristics of a superconducting element in the flux-lock type SFCL were dependent on the winding' direction between two coils, the analysis for the recovery characteristics of this type SFCL together with the current limiting characteristic is necessary to apply it to power system. As the fault cycles was increased from 1 cycle to 5 cycles, the initial limiting current ($I_{ini}$) and quench characteristic were mostly same. As the fault period increases, the recovery time of the superconducting element increases. The consumed energy and recovery characteristics in a superconducting element show the same tendency.

  • PDF

Current Limiting Characteristics according to Applied Voltage Increase of Resistive-type SFCL using YBCO Coated Conductor (YBCO Coated Conductor를 이용한 저항형 전류제한기의 인가전압 증가에 따른 전류제한 특성)

  • Du, Ho-Ik;Kim, Min-Ju;Doo, Seung-Gyu;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.854-859
    • /
    • 2009
  • The YBCO coated conductor is an important element that forms the superconducting power equipment. The first advantage of applying YBCO coated conductor to superconducting power equipment is that it can effectively addresses the normal and fault currents using less quantity of wire than when using Bi tape due to its high critical current density. Second, it can limit the fault current fast because its index value is high. so that the resistance can be produced fast when it is applied to the superconducting current limiting element. Third, the type of stabilization layer that surrounds the YBCO superconductor is selectable and the magnitude of the resistance that is produced from quenching can be adjusted. This study researched into the manufacture of current-limiting element of using YBCO coated conductor, into the characteristics of current limiter that considered by combining the manufactured element with the resistive-type superconducting fault current limiter.

Increase of Operational Current in a SFCL using Series or Parallel Coupling of Coils (코일의 직.병렬결합을 이용한 초전도 사고전류제한기의 동작전류 증가)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.46-51
    • /
    • 2007
  • The fault current limiting characteristics of superconducting fault current limiter(SFCL) using magnetic coupling of two coils were investigated. This SFCL consists of a high-TC superconducting(HTSC) element and two coils with series or parallel connection on the same iron. In normal time, the inner magnetic fluxes generated by two coils are canceled in case that the HTSC element keeps superconducting state. However, in case that the resistance of the HTSC element happens by a short-circuit the magnetic fluxes, not cancelled, induce the voltages across two coils and the fault current can be limited by the impedance of this SFCL. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the operating current of this SFCL increased more than that of HTSC element's independent operation.