• Title/Summary/Keyword: Super-cooling

Search Result 92, Processing Time 0.017 seconds

Analysis of the Relationship of Water Vapor with Precipitation for the Winter ESSAY (Experiment on Snow Storms At Yeongdong) Period (겨울철 ESSAY (Experiment on Snow Storms At Yeongdong) 기간 동안 수증기량과 강수량의 연관성 분석)

  • Ko, A-Reum;Kim, Byung-Gon;Eun, Seung-Hee;Park, Young-San;Choi, Byoung-Choel
    • Atmosphere
    • /
    • v.26 no.1
    • /
    • pp.19-33
    • /
    • 2016
  • Water vapor in the atmosphere is an important element that generates various meteorological phenomena and modifies a hydrological cycle. In general, the Yeongdong region has a lot of snow compared to the other regions in winter due to the complex topography and an adjacent East Sea. However, the phase change from water vapor to ice cloud and further snowfall has little been examined in detail. Therefore, in this study, we investigated phase change of liquid water in terms of a quantitative budget as well as time lag of water vapor conversion to snowfall in the ESSAY (Experiment on Snow Storms At Yeongdong) campaign that had been carried out from 2012 to 2015. First, we classified 3 distinctive synoptic patterns such as Low Crossing, Low Passing, and Stagnation. In general, the amount of water vapor of Low Crossing is highest, and Low Passing, Stagnation in order. The snowfall intensity of Stagnation is highest, whereas that of Low Crossing is the lowest, when a sharp increase in water vapor and accordingly a following increase in precipitation are shown with the remarkable time lag. Interestingly, the conversion rate of water vapor to snowfall seems to be higher (about 10%) in case of the Stagnation type in comparison with the other types at Bukgangneung, which appears to be attributable to significant cooling caused by cold surge in the lower atmosphere. Although the snowfall is generally preceded by an increase in water vapor, its amount converted into the snowfall is also controlled by the atmosphere condition such as temperature, super-saturation, etc. These results would be a fundamental resource for an improvement of snowfall forecast in the Yeongdong region and the successful experiment of weather modification in the near future.

Evaluation of Hydration Heat of Mass Concrete with Capsulated Slurry PCM and FEM Study for Analyzing Thermal Crack (캡슐형 슬러리 PCM을 혼입한 매스콘크리트의 수화열 평가 및 온도균열 FEM 해석에 관한 연구)

  • Park, ChangGun;Kim, Bo-Hyun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.379-388
    • /
    • 2014
  • The purpose of this study is to investigate the effect of capsulated slurry phase change material (PCM) on the thermal crack in mass concrete by experimental work and FEM analysis. In this study, three conditions of samples were prepared for evaluating the level of hydration heat, i.e., a material condition, a cement paste condition and a concrete condition. Also, a compressive strength test was conducted for FEM inverse analysis. Based on the results of the experiment, exothermic function coefficients of concrete with encapsulated slurry PCM were deducted by the inverse analysis. After that, they applied to FEM analysis of the mass scale concrete structures. From the results of this experiment, $31^{\circ}C$ capsulated slurry PCM had no super cooling phenomenon in the material condition. In the cement condition, hydration heat decreased by 34.61J when PCM of 1g was mixed. In the concrete condition, PCM of 6% was deducted as the best level in hydration heat absorption. In FEM inverse analysis, rate coefficient of reaction gradually decreased when PCM mixing ratio increased. But, temperature-rise coefficient increased when PCM mixing ratio exceeded 6%. For the inversed exothermic function coefficients applying to large scale concrete structures, a thermal cracking index increased by 0.05 when PCM of 1% was mixed.