• Title/Summary/Keyword: Super-Resolution

Search Result 445, Processing Time 0.024 seconds

Measurement of Film Thickness by Fringe Intensity Analysis in Point Contact Elastohydrodynamic Lubrication (점접촉 탄성 유체 윤활에서의 띠 무의 강도에 의한 유막 두께 측정)

  • 장시열;최언진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.103-113
    • /
    • 1999
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by the image processing method for the monochromatic incident light. Interference between the reflected lights both on Cr coating of glass disk and on super finished ball makes circular fringes, which are regarded as film thickness together with numbering of fringe order. In this study, we developed technology to measure the film thickness by analyzing dark and bright intensity waves which results from monochrome green light. Two typical fringe patterns only with intensity values 3re examined for the measurement of point contact EHL film thickness. We expect that this technology will give valuable clue to improve color image processing analysis for high resolution of EHL film thickness with white incident light.

  • PDF

Super-Resolution Algorithm by Motion Estimation with Sub-pixel Accuracy using 6-Tap FIR Filter (6-Tap FIR 필터를 이용한 부화소 단위 움직임 추정을 통한 초해상도 기법)

  • Kwon, Soon Chan;Yoo, Jisang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.106-109
    • /
    • 2011
  • 본 논문에서는 연속된 프레임을 갖는 영상의 프레임간 움직임 추정 기법을 응용하여 고해상도 영상을 획득하는 초고 해상도 기법을 제안한다. 기존의 단일 영상을 이용한 초고해상도 기법의 경우 영상에서의 고주파 대역을 찾기 위해 확률 기반의 다양한 방법이 제시되었으나 연산에 사용할 수 있는 정보가 제한적이라는 문제가 존재한다. 이러한 문제를 해결하기 위해 연속된 프레임을 이용한 다양한 초고해상도 기법이 제안되었다. 본 논문에서는 주어진 영상의 전, 후의 다수 프레임을 정하여 6-tap FIR(finite impulse response) 필터를 이용하여 프레임들의 부화소(sub-pixel)를 구한 뒤에, 부화소 정밀도의 움직임 추정을 통하여 보다 정확한 고주파성분을 복원하고자 한다. 실험을 통하여 제안하는 기법이 기존의 고등차수(bi-cubic)보간법 보다 선명한 영상을 획득할 수 있었다.

  • PDF

Super-resolution Based on Discrete Wavelet Transform (이산 웨이블릿 변환 기반 초고해상도 기법)

  • Lim, Jong Myeong;Yoo, Jisang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.139-142
    • /
    • 2011
  • 본 논문에서는 이산 웨이블릿 변환(Discrete Wavelet Transform : DWT)을 이용한 새로운 초고해상도 기법을 제안한다. 제안된 기법에서는 DWT 수행 시 수반되는 다운 샘플링 과정을 수행하지 않음으로써 입력 받은 영상과 동일한 크기의 고주파 부대역(sub-band)들을 생성하고, 이 부대역들과 입력 받은 영상을 조합하여 이산 웨이블릿 역변환(Inverse Discrete Wavelet Transform : Inverse DWT)을 수행함으로써 고해상도의 영상을 획득한다. 실험을 통하여 제안된 기법이 이중 선형 보간법(bilinear interpolation)에 비해 향상된 효율을 보이며, 확률 기반의 기법들에 비해 처리시간도 줄어드는 것을 확인하였다.

  • PDF

On the route towards Si-based full color LED microdisplays for NTE applications

  • Smirnov, A.;Labunov, V.;Lazarouk, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.727-731
    • /
    • 2005
  • Design and manufacturing process of a full color LED microdislay fabricated by standard CMOS technology and containing an array of aluminum / nanostructured porous silicon reverse biased light emitting Schottky diodes will be discussed. Being of a solid state construction, this microdisplays are cost-effective, thin and light in weight due to very simple device architecture. Its benefits include also super high resolution, wide viewing angles, fast response time and wide operating temperature range. The advantages of full integration of an LED-array and driving circuitry onto a Si-chip will be also discussed.

  • PDF

Measurements of Evanescent Wave using a Mano-size Optical Probe (나노 사이즈 광프로브에 의한 에버네슨트파의 측정)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.

Host galaxy of tidal disruption object, Swift J1644+57

  • Yoon, Yongmin;Im, Myungshin;Lee, Seong-Kook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.48.2-48.2
    • /
    • 2014
  • We present long-term optical to NIR data of the tidal disruption object, Swift J1644+57. The data were obtained with CQUEAN, UKIRT WFCAM observations. We analyze the morphology of the host galaxy of this object and decompose the bulge component using high resolution HST WFC3 images. We conclude that the host galaxy is bulge dominant. We also estimate the multi-band fluxes of the host galaxy through the light curves based on the long-term observational data. We fit the SED models to the multi-band fluxes of the host galaxy and determine its stellar mass. Finally, we estimate the mass of the central super massive black hole which is responsible for the tidal disruption event. The estimated stellar mass and black hole mass are ${\sim}10^{9.1}M_{\odot}$, ${\sim}10^{6.8}M_{\odot}$, respectively. We compare our results to other previous estimates.

  • PDF

Super-Resolution Image Processing Algorithm Using Hybrid Up-sampling (하이브리드 업샘플링을 이용한 베이시안 초해상도 영상처리)

  • Park, Jong-Hyun;Kang, Moon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.109-110
    • /
    • 2007
  • 본 논문에서는 베이시안 초해상도 영상처리시 저해상도 영상들을 고해상도 격자에 맞게 정합해서 업샘플링(upsampling)을 하는 새로운 방식에 대해 제안한다. 제안하는 업샘플링 방식은 각 장을 따로 보간하는 방식과 달리 여러 저해상도 영상의 고주파 정보가 고해상도 영상 격자의 모든 위치에 적절히 영향을 미칠 수 있도록 여러 장의 저해상도 영상의 고주파 정보를 함께 사용하여 보간한다. 보간하는 방법은 B-스플라인 (B-Spline) 기반 비정규 리샘플링(non-uniform resampling)을 기반으로 초해상도 영상처리에 맞도록 적용한다. 실험결과를 통해 일반적으로 적용되는 0-삽입(zero-padding) 업샘플링 방식과 쌍일차 보간법(bilinear interpolation) 등을 적용할 때의 효과를 살펴보고, 제안하는 방식이 일반적인 방식을 사용하는 것에 비해 정량적, 정성적으로 고해상도 정보를 더 정확히 생성해내는 것을 확인한다.

  • PDF

A study on the implementation of Imaging System for Magnetic Resonance Imaging (자기공명전단을 위한 영상화 시스템 구현에 관한 연구)

  • Jin, S.O.;Won, J.I.;Park, Y.H.;Huh, Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.597-599
    • /
    • 1998
  • The clinical acceptance of magnetic resonance imaging(MRI) system has been more rapid than that of the other medical image diagnosis system(X-ray, CT, etc) with the advantage of nonhazardous nature, high resolution capability, potential for chemically specified imaging. MRI system is composed of super conducting magnet, gradient fields, rf transceiver, system controller and imaging software technology. In this paper, introducing the principle of magnetic resonance imaging, it proposes the implementation of PC-based MRI system.

  • PDF

Super-resolution Algorithm for Infra-red Images (IR 영상을 위한 초고해상도 알고리즘)

  • Kim, Yong Jun;Choi, Dong Yoon;Song, Byung Cheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.11a
    • /
    • pp.152-153
    • /
    • 2015
  • 일반 영상의 영상확대를 위한 다양한 알고리즘이 존재한다. 하지만 IR 영상의 경우 일반영상과 다른 특성을 가지고 있기 때문에 IR 영상을 위한 영상 확대 알고리즘이 필요하다. 따라서 IR 영상이 일반영상에 비해 디테일이 없다는 특성을 고려하여 복잡한 알고리즘을 적용시키기 보다는 ADRC[1]와 같은 단순한 분류 기법을 활용하여 LR-HR 패치를 분류하고 학습된 데이터를 이용하여 영상확대 알고리즘에 적용하였다. 또한 알고리즘의 성능을 향상시키기 위해 학습과정에 전처리 과정을 추가하여 알고리즘 작동 시 연산량의 증가 없이 확대 영상의 선명도를 향상시키고자 하였다. 이와 같은 방법으로 영상 확대 알고리즘을 수행하였을 때 통상적인 영상확대 기법인 bi-cubic interpolation 기법보다 CPBD 수치가 평균 0.0527 만큼 높은 결과를 확인할 수 있었고 전처리 과정을 추가하였을 때 이전보다 평균 0.0119 만큼 더 선명해진 영상을 얻었다.

  • PDF

Sub-Pixel Motion Estimation by Using Only integ-Pixel (고속 보간 법을 이용한 Super-Resolution 복원 기법)

  • Cho, Hyo-Moon;Lee, Si-Kyong;Yang, Myung-Kook
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.379-380
    • /
    • 2007
  • In this paper, we propose the fast hi-linear interpolation method for SR reconstruction. This method reconstructs the HR image rapidity by considering motion vector information for each LR input image. And its calculation used normalized deviation of image data. As using the motion vector information which is obtained at registration error checking process, this proposed can be achieved the fast and simple SR reconstructed image.

  • PDF